Wiring Diagrams - Danby DAS120EAQHWDB Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRUCTIONS
INSTALLATION - INFORMATION FOR THE INSTALLER
Inverter type model capacity (btu/h)
Gas pipe diameter
Additional refrigerant charge
Other notes
• Liquid pipe diameter: 1/4" (ø6)
• Length of pipe with standard charge: 7.5 meters
• Maximum distance allowed between indoor and outdoor units: 15 meters
• Maximum difference allowed in level between indoor and outdoor units: 5 meters
• Type of refrigerant: R410a
Tightening torque for protection caps and fl ange connection
Pipe
Tightening torque
(N x m)
1/4" (ø6)
15 - 20
3/8" (ø9.52)
31 - 35
1/2" (ø12.7)
35 - 45
5.8" (ø15.88)
75 - 80

WIRING DIAGRAMS

The wiring diagram may be different for different
models. Refer to the wiring diagrams on both the
indoor and outdoor units.
On the indoor unit, the wiring diagram is located
under the front panel.
On the outdoor unit, the wiring diagram is located
on the back of the outdoor handle cover.
Note: Some models will have wires connected to
the main PCB of the indoor unit without a terminal
block.
9K
12K
3/8"
3/8"
(ø9.52)
(ø9.52)
20g/m
20g/m
Corresponding stress
(using 20 cm wrench)
wrist strength
arm strength
arm strength
arm strength
12
18K
24K
3/8"
1/2"
(ø9.52)
(ø12.7)
20g/m
20g/m
Tightening
torque (N x m)
service port nut
7 - 9
protection caps
25 - 30
36K
1/2"
(ø12.7)
30g/m

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Das180eaqhwdb

Table of Contents