Top Vent - Vertical Termination - (continued)
Three Elbows
Note: Use SLP Series
components only.
**
Note: When using SLP-FLEX (6-5/8 in.) venting, there
MUST be a 25% reduction in total H when using flex vent.
See Figure 4.8.
Figure 4.18
Majestic • QUARTZ32IFTN/L, QUARTZ36IFTN/L, QUARTZ42IFTN/L Installation Manual • 2641-980 Rev. C • 9/20
V
MIN.
1
90 Elbow
1/2 ft.
152 mm
1-1/2 ft. 457 mm
2-1/2 ft. 762 mm
3-1/2 ft.
1.1 m
4-1/2 ft.
1.4 m
V
1
* No specific restrictions on this value EXCEPT V
V
2
H
2
INSTALLED
HORIZONTALLY
H MAX.**
V
1/2 ft.
152 mm
*
1 ft.
305 mm
*
2 ft.
610 mm
*
4 ft.
1.2 m
*
6 ft.
1.8 m
*
14 ft.
4.3 m
*
H MAX. =14 ft. (4.3 m)
+ V
+ H
+ H
MAX. = 40 ft. (12.2 m)
2
1
2
cannot exceed 40 ft. (12.2 m)