VCM100 screen (drain) wire extension

The screen (drain) wire can be extended for longer cable runs between the VCM100 and your
vessel's RF ground system.
Extensions to the screen (drain) wire should use an 8 mm braid or AWG 10 (5.26 mm
cable.

Circuit breaker and fuse ratings

Battery isolator switch, thermal breaker, and fuse ratings.
All power connections between the VCM100 and its power source must be protected by a thermal
circuit breaker or fuse, fitted close to the power connection. The connection from the output of the
VCM100 to the digital radar does not require a fuse or circuit breaker.
If you do not have a thermal circuit breaker or fuse in your power circuit (fitted to the DC distribution
panel, for example), you MUST fit an in-line breaker or fuse to the positive wire of the power cable.
The following table provides suitable ratings for battery isolator switches, circuit breakers, and fuses.
Power supply
12 volt
24 volt
Warning: Product grounding
Before applying power to this product, ensure it has been correctly grounded, in
accordance with the instructions provided.
Power connections
Device
Isolator switch
Thermal breaker
Fuse
Isolator switch
Thermal breaker
Fuse
4 kW scanner
30 amps (minimum
rating)
15 amps
20 amps
15 amps (minimum
rating)
8 amps
10 amps
) multi-stranded
2
12 kW scanner
30 amps (minimum
rating)
15 amps
20 amps
15 amps (minimum
rating)
8 amps
10 amps