Error Codes - Elation ARTISTE MONDRIAN User Manual

Table of Contents

Advertisement

E R R O R C O D E S
When power is applied, the unit will automatically enter a "Reset/Test" mode. This mode brings all
the internal motors to a home position. If there is an internal problem with one or more of the motors
an error code will flash in the display in the form of "XXer" were as XX will represent a function
number. For example, when the display shows "0Er" it means there is some type of error with the
Pan motor. If there are multiple errors during the start-up process they will all flash in the display. For
example: if the fixtures has errors on Channel 1, 2, and 5 all at the same time, you will see the error
message "01Er", "02Er", and "05Er" flash repeated 5 times.
If an error does occur during the initial start-up procedure the fixture will self-generate a second reset
signal and try to realign all the motors and correct the errors. If the error persists after a second
attempt a third attempt will be made. If after a third attempt all the errors have not been corrected the
fixture will make the following determinations:
3 or More Errors - The fixture cannot function properly with three or more errors; therefore, the
fixture will place itself in a stand-by mode until subsequent repairs can be made.
Less Than 3 Errors - The fixture has less than 3 errors; therefore, most other functions will work
properly. The fixture will attempt to operate normally until the errors can be correct by a technician.
The errors in question will remain flashing in the display as a reminder of internal errors.

ERROR CODES

PAN Er
TILT Er
Cyan Color Er
Magenta Color Er
Yellow Color Er
CTO Color Er
Color Wheel1 Er
Focus Er
Zoom Er
Iris Er
AllBladeRotation Er
Prism1 Er
Prism2 Er
Prism_Rot1 Er
Prism_Rot2 Er
Animation Er
AnimationRot Er
Error Codes subject to change without notice.
DESCRIPTION
Movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed, or magnet is missing) or there is a
motor failure (defective motor or a defective motor IC drive on the main
PCB). This error may also be displayed if the head/yoke was blocked
during a reset function.
Movement is not located in the default position after the
reset. This message will appear after a fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed, or
magnet is missing), or there is a motor failure (defective
motor or a defective motor IC drive on the main PCB).