Advertisement

5. In the Emergency Response pane, set the signal output when the trigger is received.
When the Fire Alarm signal is changed from inactive to active, the signal that is set in Emergency
Response is output.
A maximum of four signals can be output from a GPIO channel (only an output pin) when the trigger
set is received. They are used to make the lighting in a theater brighter when a fire alarm is detected.
The items in the Automation pane of GPIO Profile are displayed as the options of the output signal.
6. In the Emergency Recovery pane, set the signal output when the trigger is canceled.
When the Fire Alarm signal is changed from inactive to active, the signal that is set in Emergency
Recovery is output.
A maximum of four signals can be output from a GPIO channel (only an output pin) when the trigger
set is received.
A maximum of four signals can be output from a GPIO channel (only an output pin) when the trigger
set is canceled. They are used to cancel the control item set in step 3.
The items in the Automation pane of GPIO Profile are displayed as the options of the output signal.
n
Fire Alarm and Projector Stop are canceled in the following cases:
. For Fire Alarm:
When a Fire Alarm signal becomes inactive and when [Clear|Emergency] in
the left corner of a "Status-Error History" screen is tapped
. For Projector Stop: When a projector returns to the normal state and when the playback button is
pressed
7. Tap [Apply].
The setting is saved.
n
The Emergency Response/Emergency Recovery signal is output only when the active state of the Fire
Alarm signal is changed.
Even if the Fire Alarm signal is inactive during startup, the signal that is set in Emergency Recovery is not
output.