Clearances To Combustible Material; Clearances - Drolet ESCAPE 1200 Owner's Manual

Hide thumbs Also See for ESCAPE 1200:
Table of Contents

Advertisement

3. Clearances to Combustible Material

The clearances shown in this section have been determined by tests according to procedures
set out in safety standards ULC S627 (Canada), UL 1482 (U.S.A.) and UL 737 (U.S.A.). When
the stove is installed so that its surfaces are at or beyond the minimum clearances specified,
combustible surfaces will not overheat under normal and even abnormal operating conditions.
No part of the stove or flue pipe may be located closer to combustibles than the minimum
clearance figures given.
The clearances to combustible walls may be slightly different in Canada and the U.S.A. and may
also differ depending on whether single or double wall flue pipe is used. Make sure to choose
the correct clearance for the stove location and type of flue pipe.
The clearances of the appliance and the flue pipes must be met individually, meaning the
appliance cannot be installed closer to the combustible materials than the single or double wall
pipe allows. For a safe way to reduce clearances refer to section"5. Reducing Wall and Ceiling
Clearances Safely"
3.1

Clearances

APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
A
14" (356 mm)
B
18" (457 mm)
C
11" (279 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
14
WITH SINGLE WALL PIPE CONNECTOR
Canada
D
18" (457 mm)
E
24 ½" (622 mm)
F
18 ¼" (464 mm)
14
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
Installation and Operation Manual - Escape 1200
USA
12" (305 mm)
18" (457 mm)
11" (279 mm)
FROM PIPE CONNECTOR
USA
16" (406 mm)
24 ½" (622 mm)
18 ¼" (464 mm)
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
6" (152 mm)
B
18" (457 mm)
C
7" (178 mm)
DISTANCES
FROM PIPE CONNECTOR
14
WITH DOUBLE WALL PIPE CONNECTORE
Canada
D
9 ¼" (235 mm)
E
23 ¾" (603 mm)
F
13 ½" (343 mm)
USA
6" (152 mm)
18" (457 mm)
7" (178 mm)
USA
9 ¼" (235 mm)
23 ¾" (603 mm)
13 ½" (343 mm)
Page 11