ACP 106 EU/MK • Setup Guide (Continued)
Step 5: Cable All Devices
Connect the ACP panel to the host device.
1.
Connect ACP panels to each other if multiple panels are being used in the control system (see the wiring diagram below for
2.
correct wiring).
NOTES:
Wire both ends of each ACP cable the same. Connectors are interchangeable between the host device and ACP
device.
Do NOT power an ACP panel from more than one power source.
Apply power to the host device after correctly cabling all devices.
3.
Cabling
Attach cables using the diagram below as a guide. Wiring is the same for all ACP models. Connect a 4-pole captive screw
connector to each end of the cable, wiring both ends the same. In most cases, the ACP devices are powered by the host
DMP Plus Series device. Power is carried on the V+ pin of the ACP 106 EU/MK and other ACP devices.
Extron STP20-2/1000 or STP20-2P/100 cable is recommended for ACP device connections.
+V
+12 VDC
+S
+ Signal
-S
- Signal
G
Ground
ACP devices that are relatively far from the host device can be connected to an optional Extron PS 1220EB eBUS power inserter
or an Extron 12 VDC desktop power supply as shown in the diagrams below and on the next page (see the
ACP 106 EU/MK Specifications at
ATTENTION:
Always use a power supply supplied or specified by Extron. Use of an unauthorized power supply voids all regulatory
compliance certification and may cause damage to the supply and the unit.
Utilisez toujours une source d'alimentation fournie par Extron. L'utilisation d'une source d'alimentation non autorisée
annule toute conformité réglementaire et peut endommager la source d'alimentation ainsi que l'unité.
If not provided with a power supply, this product is intended to be supplied by a UL Listed power source marked
"Class 2" or "LPS" and rated output 12 VDC, minimum 1.0 A.
Si ce produit ne dispose pas de sa propre source d'alimentation électrique, il doit être alimenté par une source
d'alimentation certifiée UL de classe 2 ou LPS et paramétré à 12 VDC et 1,0 A minimum.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d'aération
ou dans les cavités murales.
The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70,
article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to
building structure or similar structure.
Cette installation doit toujours être en accord avec les mesures qui s'applique au National Electrical Code ANSI/
NFPA 70, article 725, et au Canadian Electrical Code, partie 1, section 16. La source d'alimentation ne devra pas être
fixée de façon permanente à une structure de bâtiment ou à une structure similaire.
4
Red
Green
White
Black
and
Drains
Drain Wires
Basic ACP Connector Wiring
www.extron.com
for cable length to determine if additional power is recommended).