Chapter 2. Installing the Pipe Nozzles

2.4.5 Installing the First Nozzle - MR2 Mid-Radius

CAUTION!
threaded rod provided in the installation kit, prior to welding the nozzle.
To install the first nozzle, complete the following steps:
1. Screw the threaded rod into either welding boss that has been welded to the pipe, as shown in Figure 61 below.
If necessary, remove the washer and nut from the threaded rod.
2. Slide the nozzle over the threaded rod, and align the contoured end of the nozzle so it matches the pipe arc.
Then slide the jig over the threaded rod, fitting the jig into the welding boss (see Figure 62 below).
50
It is essential that the nozzle be set up and fixed in position using the jig and the 1-in.
Figure 61: Inserting the Threaded Rod
Figure 62: Inserting the Nozzle and Jig
Model T17 Installation Guide