Datalogic DSM0400 Product Reference Manual

Datalogic DSM0400 Product Reference Manual

Fixed mount area imager bar code reader
Hide thumbs Also See for DSM0400:
Table of Contents

Advertisement

DSM0400
Fixed Mount Area Imager
Bar Code Reader
Product Reference Guide

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic DSM0400

  • Page 1 DSM0400 Fixed Mount Area Imager Bar Code Reader Product Reference Guide...
  • Page 2 Datalogic S.p.A. and/or its affiliates. Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes.
  • Page 3: Table Of Contents

    Setting Up the Scanner ......................................5 Connect Host Interface ....................................6 RS-232 Serial Connection ..................................6 USB Connection ......................................6 DSM0400 Mounting using brackets ................................7 Multi side Mounting Bracket ................................7 Angular Bracket (-17° to 25° Angle Mounting) ..........................8 Both Brackets applied ....................................8 Using the DSM0400 .........................................
  • Page 4 Code 32 Enable/Disable ................................98 Code 32 Feature Setting Exceptions ............................98 Code 32 Check Char Transmission ............................99 Code 32 Start/Stop Character Transmission ........................... 99 CODE 39 CIP (FRENCH PHARMACEUTICAL) ............................. 100 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 5 IATA Check Character Transmission ............................124 DATALOGIC 2 OF 5 ....................................125 Datalogic 2 of 5 Enable/Disable .............................. 125 Datalogic 2 of 5 Check Character Calculation ......................... 125 Datalogic 2 of 5 Length Control ............................... 126 Datalogic 2 of 5 Set Length 1 ..............................127 Datalogic 2 of 5 Set Length 2 ..............................
  • Page 6 Data Matrix Set Length 2 ................................. 179 DOTCODE ......................................180 DotCode Enable / Disable ................................ 180 DotCode Length Control ................................180 DotCode Set Length 1 ................................181 DotCode Set Length 2 ................................182 DotCode High Resolution ................................. 183 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 7 Contents DotCode Constant Position ..............................183 DotCode Maximum Dot Diameter ............................184 DotCode Minimum Dot Diameter ............................185 MAXICODE ......................................186 Maxicode Enable / Disable ............................... 186 Maxicode Primary Message Transmission ..........................186 Maxicode Length Control ................................187 Maxicode Set Length 1 ................................188 Maxicode Set Length 2 ................................
  • Page 8 1D Bar Codes ....................................235 1D Bar Codes - continued ................................. 236 GS1 DataBar™ (RSS) ......................................237 GS1 DataBar™-14 ........................................237 2D Bar Codes .........................................238 ASCII Chart ..........................................239 KEYPAD........................................241 HID Variable PIN Code ......................................243 DSM0400 Fixed Mount Area Imager Bar Code Reader viii...
  • Page 9: Introduction

    'Green Spot' for good-read feedback helps to improve productivity in noisy environments or in situations where silence is required. The DSM0400 reliably decodes all standard 1D (linear) and 2D bar codes, including DataBar™ codes (Omnidirectional, Expanded, Stacked), Postal Codes (China Post). The data stream - acquired from decoding a symbol - is rapidly sent to the host.
  • Page 10: Overview

    Programming can also be performed using the protocol “Decoded Engine Serial Protocol” (DESP) or using Datalogic Aladdin™ Configuration applica- tion, downloadable from the Datalogic website. This multi-platform utility programs allow device configuration using a PC. It communicates with the device using a serial or USB cable and can also create configuration barcodes to print.
  • Page 11: Technical Support

    Support. Reseller Technical Support An excellent source for technical assistance and information is an autho- rized Datalogic reseller. A reseller is acquainted with specific types of busi- nesses, application software, and computer systems and can provide individualized assistance. Product Reference Guide...
  • Page 12 Introduction NOTES DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 13: Setup

    Follow the steps provided in this section to connect and get your scanner up and communicating with its host: 1. (DSM049X Models only) IMPORTANT: First of all, connect the Datalogic Inter- face Cable (not included - to be selected among the possible accessories) to the scanner as shown in Figure 1.
  • Page 14: Connect Host Interface

    Figure 2 are examples only. Actual connectors may vary from those illustrated, but the steps to connect the scanner remain the NOTE same. Figure 2 - Connection to Host Interface DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 15: Dsm0400 Mounting Using Brackets

    Setting Up the Scanner DSM0400 Mounting using brackets The brackets are included for mounting the DSM0400 onto a stationary surface, on all sides or with different angles. Attach the desired bracket to the bottom of the reader using the provided screws, as shown in the figures below. See Appendix A for the mechanical drawings.
  • Page 16: Angular Bracket (-17° To 25° Angle Mounting)

    Setup Angular Bracket (-17° to 25° Angle Mounting) Both Brackets applied N.4 M2x0.4X4 ISO14583 NYLOK 180 T6 SCREWS, N.4 LOCK WASHERS UNI 1751 INCLUDED DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 17: Using The Dsm0400

    Using the DSM0400 Using the DSM0400 The DSM0400 normally functions by capturing and decoding codes. The aiming system is activated on trigger pull and indicates the center of the field of view which should be positioned over the bar code:...
  • Page 18: Interface Selection

    USB Composite (Keyboard + COM) • RS-232 STD For an improved ease of installation, the DSM0400 features a cable auto-rec- ognition procedure at the startup: • if a RS232 cable is used, the device will always boot in the RS232 interface configuration.
  • Page 19 Interface Selection Table 1. Available Interfaces RS-232 standard interface (Interface features starting on page 17) Select RS232-STD USB Com emulating RS-232 standard interface Select USB-COM USB-OEM (can be used for OPOS/UPOS/JavaPOS) (Interface features starting on page 51) Select USB-OEM USB-Keyboard with standard key encoding (Interface features starting on page 23) Select USB-Keyboard USB-Composite...
  • Page 20: Customizing Configuration Settings

    DESP is also available as a software library, in order to enhance the appli- cation development. The provided APIs covers the most common activities, such as acquisition and configuration, so that DSM0400 can be controlled and configured using its communication interface with the host. The SDK can also be used for software update.
  • Page 21: Interface Settings

    Interface Settings The scanner is typically factory-configured with a set of default features stan- dard to the interface type you ordered. See Using the DSM0400 on page Configuration Using Bar Codes provides settings configurable by all interface types. If your installation requires you to further customize your scanner, you can select other options through use of the instructions and programming bar codes available in the appropriate section for your interface.
  • Page 22 The DSM0400 decoder supports either DM configuration or C128 configuration barcodes.In this manual only C128 labels are included. The DSM0400 default uses C128 labels for configuration. To switch back and forth between the two barcode types, scan the following barcodes:...
  • Page 23: Configuration Using Bar Codes

    Chapter 3 Configuration Using Bar Codes This and following sections provide programming bar codes to configure your scanner by changing the default settings. For details about additional methods of programming, see "Customizing Configuration Settings" on page You must first enable your scanner to read bar codes in order to use this section.
  • Page 24 4. Complete the programming sequence by scanning the ENTER/EXIT PRO- GRAMMING MODE bar code to exit Programming Mode. For more detailed description, programming information and examples for set- ting selected configuration items, see Chapter 4, References. DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 25: Only Interface

    RS-232 ONLY INTERFACE Use the programming bar codes in this chapter if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. on page 18 on page 19 on page 19 on page 20 ARITY on page 21 ANDSHAKING ONTROL Product Reference Guide...
  • Page 26: Baud Rate

    Baud Rate = 1200 Baud Rate = 2400 Baud Rate = 4800 Baud Rate = 9600 Baud Rate = 19,200 Baud Rate = 38,400 Baud Rate = 57,600 DEFAULT Baud Rate = 115,200 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 27: Data Bits

    Enter/Exit Programming Mode Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data. 7 Data Bits DEFAULT 8 Data Bits Stop Bits The stop bit(s) at the end of each transmitted character marks the end of trans- mission of one character and prepares the receiving device for the next charac- ter in the serial data stream.
  • Page 28: Parity

    Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character. DEFAULT Parity = None Parity = Even Parity = Odd DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 29: Handshaking Control

    Enter/Exit Programming Mode Handshaking Control The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking Control includes the following options: • None - No HW flow control •...
  • Page 30 NOTES DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 31: Usb Keyboard Only Interface

    USB KEYBOARD ONLY INTERFACE Use the programming bar codes in this chapter to select options for USB Key- board only Interface. on page 24 OUNTRY on page 46 ALT I ETTING NPUT on page 46 ALT O ETTING UTPUT on page 47 EYBOARD UMERIC EYPAD...
  • Page 32: Country Mode

    The Country Mode setting is ignored if the interface uses alternate key encod- ing. Setup on PC to use ALT Universal 1. Open Registry Edit 2. Set EnableHexNumpad to 1 as follows: 3. Reset the PC. DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 33: Setting Country Mode

    Enter/Exit Programming Mode Setting Country Mode DEFAULT United States French International (Belgian French) United Kingdom Danish French (France) German Italian Product Reference Guide...
  • Page 34 Enter/Exit Programming Mode Setting Country Mode (continued) Norwegian Portuguese Portugal Spanish Swedish Swiss French Japanese ASCII Hungarian DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 35 Enter/Exit Programming Mode Setting Country Mode (continued) Czech SlovaK Romanian Croatian Polish_214 Canadian French Win7 Lithuanian Product Reference Guide...
  • Page 36 Enter/Exit Programming Mode Setting Country Mode (continued) Vietnamese Russian Arabic 101 Chinese ASCII Thai-Kedmanee Albanian Arabic 102 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 37 Enter/Exit Programming Mode Setting Country Mode (continued) Arabic 102 AZERTY Azeri Cyrillic Azeri Latin Belarusian Bosnian Cyrillic Bosnian Latin Bulgarian Cyrillic Product Reference Guide...
  • Page 38 Enter/Exit Programming Mode Setting Country Mode (continued) Bulgarian Latin Canadian French (Legacy) Canadian Multilingual Chinese (Simplified) Chinese (Traditional) Czech Programmers Czech QWERTY DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 39 Enter/Exit Programming Mode Setting Country Mode (continued) Dutch Netherland Estonian Faeroese Finnish French (Canada) 2000/XP French (Canada) 95/98 Galician Product Reference Guide...
  • Page 40 Enter/Exit Programming Mode Setting Country Mode (continued) Greek Greek Latin Greek Polytonic Greek220 Greek220 Latin Greek319 Greek319 Latin DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 41 Enter/Exit Programming Mode Setting Country Mode (continued) Hebrew Israel Hungarian_101KEY Icelandic Irish Italian_142 Japanese (Shift-JIS) Kazakh Product Reference Guide...
  • Page 42 Enter/Exit Programming Mode Setting Country Mode (continued) Korean (Hangul) Korean ASCII Kyrgyz Cyrillic Latin America Latvian Latvian QWERTY Lithuanian_IBM DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 43 Enter/Exit Programming Mode Setting Country Mode (continued) Macedonian -FYROM Maltese_47KEY Mongolian-Cyrillic Polish Programmer Portuguese Brazil Portuguese Brazilian ABNT Portuguese Brazilian ABNT2 Product Reference Guide...
  • Page 44 Enter/Exit Programming Mode Setting Country Mode (continued) Romanian Legacy Romanian Programmer Romanian Standard $CKBCO0B  Russian Typewriter Serbian Cyrillic Serbian Latin Slovak QWERTY DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 45 Enter/Exit Programming Mode Setting Country Mode (continued) Slovenian Spanish Variation Swiss German Tatar Turkish F Turkish Q Ukrainian Product Reference Guide...
  • Page 46 Enter/Exit Programming Mode Setting Country Mode (continued) US Dvorak US Dvorak Left Hand US Dvorak Right Hand US English (Mac) US English (North American) US International Uzbek Cyrillic DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 47: Setting Encoding Type

    Enter/Exit Programming Mode Setting Encoding Type. DEFAULT Don’t use encoding UTF_8 Windows 874 Windows 932 Windows 936 Windows 949 Windows 950 Product Reference Guide...
  • Page 48 Enter/Exit Programming Mode Setting Encoding Type. (continued) Windows 1250 Windows 1251 Windows 1252 Windows 1253 Windows 1254 Windows 1255 Windows 1256 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 49 Enter/Exit Programming Mode Setting Encoding Type (continued) Windows 1257 Windows 1258 Windows 20866 ISO 8859-1 ISO 8859-2 ISO 8859-3 ISO 8859-4 Product Reference Guide...
  • Page 50 Enter/Exit Programming Mode Setting Encoding Type. (continued) ISO 8859-5 ISO 8859-6 ISO 8859-7 ISO 8859-8 ISO 8859-9 ISO 8859-10 ISO 8859-11 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 51 Enter/Exit Programming Mode Setting Encoding Type (continued) ISO 8859-13 ISO 8859-14 ISO 8859-15 ISO 8859-16 MS-DOS 437 MS-DOS 737 MS-DOS 775 Product Reference Guide...
  • Page 52 Enter/Exit Programming Mode Setting Encoding Type. (continued) MS-DOS 850 MS-DOS 852 MS-DOS 855 MS-DOS 857 MS-DOS 860 MS-DOS 861 MS-DOS 862 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 53 Enter/Exit Programming Mode Setting Encoding Type (continued) MS-DOS 863 MS-DOS 865 MS-DOS 866 MS-DOS 869 Mac CP10000 Product Reference Guide...
  • Page 54: Setting Alt Input Type

    Keyboard Country). ALT Codepage: (use on non Unicode application: Notepad) ALT Unicode: (use on Unicode application: Word) DEFAULT ALT Universal: (Use for all) DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 55: Keyboard Numeric Keypad

    Enter/Exit Programming Mode Keyboard Numeric Keypad This feature specifies if numeric characters will be sent using the standard keys or the numeric keypad. DEFAULT Keyboard Numeric Keypad = Standard Keys Keyboard Numeric Keypad = Numeric Keypad Keyboard Send Control Characters This feature is used by USB Keyboard only interface.
  • Page 56: Usb Keyboard Speed

    USB Keyboard Speed = 2ms USB Keyboard Speed = 3ms USB Keyboard Speed = 4ms USB Keyboard Speed = 5ms USB Keyboard Speed = 6ms USB Keyboard Speed = 7ms USB Keyboard Speed = 8ms DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 57 Enter/Exit Programming Mode USB Keyboard Speed - continued USB Keyboard Speed = 9ms USB Keyboard Speed = 10ms USB Keyboard Speed = 11ms USB Keyboard Speed = 12ms USB Keyboard Speed = 13ms USB Keyboard Speed = 14ms USB Keyboard Speed = 15ms USB Keyboard Speed = 16ms USB Keyboard Speed = 17ms Product Reference Guide...
  • Page 58 Enter/Exit Programming Mode USB Keyboard Speed - continued USB Keyboard Speed = 18ms USB Keyboard Speed = 19ms USB Keyboard Speed = 20ms DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 59: Usb-Oem Only Interface

    USB-OEM ONLY INTERFACE on page 51 NTRODUCTION on page 52 USB-OEM D EVICE SAGE Introduction Feature settings for USB interfaces differ depending upon which host type the scanner will be connected with. Use the feature settings in this chapter to spe- cifically configure for the USB-OEM interface.
  • Page 60: Usb-Oem Device Usage

    It may be necessary to switch device usage when connecting two scanners of the same type to a POS system. NOTE DEFAULT USB-OEM Device Usage = Tabletop Scanner USB-OEM Device Usage = Handheld Scanner DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 61: Data Format

    DATA FORMAT on page 54 LOBAL REFIX UFFIX on page 55 AIM ID LOBAL on page 56 GS1-128 AIM ID The features in this chapter can be used to build specific user-defined data into a message string. Chapter 4, References for more detailed instructions on setting these fea- tures.
  • Page 62: Global Prefix/Suffix

    The default is <CR> character suffix. For setting <CR> character as global Suf- fix, enter Programming Mode, then read the following bar code and then exit Programming Mode DEFAULT Global Suffix: OD (hex code for <CR>) DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 63: Global Aim Id

    Enter/Exit Programming Mode Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. NOTE AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. See "Global AIM ID"...
  • Page 64: Gs1-128 Aim Id

    The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3. AIM IDs for other symbologies can be enabled/disabled independently as well. Contact Customer Support for assistance. GS1-128 AIM ID = Disable DEFAULT GS1-128 AIM ID = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 65: Reading Parameters

    READING PARAMETERS on page 58 OUBLE IMEOUT on page 60 PEAKER NDICATORS on page 60 PEAKER OLUME ) LED I NABLE ISABLE REEN NDICA on page 61 on page 61 NABLE ISABLE RIGGER INDICATOR on page 61 LED I NABLE ISABLE OWER NDICATOR...
  • Page 66: Double Read Timeout

    Double Read Timeout = 0.1 Second Double Read Timeout = 0.2 Second Double Read Timeout = 0.3 Second Double Read Timeout = 0.4 Second DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 67 Enter/Exit Programming Mode Double Read Timeout (continued) Double Read Timeout = 0.5 Second Double Read Timeout = 0.6 Second Double Read Timeout = 0.7 Second Double Read Timeout = 0.8 Second Double Read Timeout = 0.9 Second DEFAULT Double Read Timeout = 1 Second Product Reference Guide...
  • Page 68: Led And Speaker Indicators

    Selects the speaker volume (loudness) upon a good read beep. There are three selectable volume levels. Good Read Speaker Volume = Speaker Off Good Read Speaker Volume = Low Good Read Speaker Volume = Medium DEFAULT Good Read Speaker Volume = High DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 69: Enable/Disable Green Spot (Good Read) Led Indicator

    Enter/Exit Programming Mode Enable/Disable Green Spot (Good Read) LED Indicator Enable/Disable the green spot (good read) LED indicator. Green Spot = Disable DEFAULT Green Spot = Enable Enable/Disable Trigger LED indicator Enable/Disable Trigger LED Indicator (blue LED) Trigger LED = Disable DEFAULT Trigger LED = Enable Enable/Disable Power LED Indicator...
  • Page 70: Scanning Features

    DEFAULT Scan Mode = Trigger Single Scan Mode = Trigger Hold Multiple Scan Mode = Trigger Pulse Multiple Scan Mode = Flashing Scan Mode = Always On Scan Mode = Stand Mode DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 71: Flash On Time

    Enter/Exit Programming Mode Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Always use two digits (e.g.: scan the barcode '0' and the barcode '2' for setting 0.2 seconds).
  • Page 72: Flash Off Time

    Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 05 = Flash is OFF for 500ms DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 73: Stand Mode Sensitivity

    Enter/Exit Programming Mode Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high. Stand Mode Sensitivity = Low DEFAULT Stand Mode Sensitivity = Medium Stand Mode Sensitivity = High Product Reference Guide...
  • Page 74: Scanning Active Time

    Here the labels for quick configuration on 3, 5 or 8 seconds. More options are available using DESP or Aladdin configuration proto- cols. Scanning Active Time = 3 seconds DEFAULT Scanning Active Time = 5 seconds Scanning Active Time = 8 seconds DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 75: Pick Mode

    Enter/Exit Programming Mode Pick Mode Specifies the ability of the reader to decode labels only when they are close to the center of the aiming pattern. This allows the reader to accurately target labels when they are placed close together, such as on a pick sheet. The Pick Mode can be enabled only in Trigger Single Scan Mode.
  • Page 76: Aiming Pointer

    Specifies the duration of the good read pointer beam after a good read. Green Spot Duration = Disable (Green Spot is Off) DEFAULT Green Spot Duration = Short (300 msec) Green Spot Duration = Medium (500 msec) Green Spot Duration = Long (800 msec) DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 77: Enhanced Mobile Phone Mode

    Enter/Exit Programming Mode Enhanced Mobile Phone Mode This mode is useful for improving reading performances when scanning bar codes displayed on a mobile phone. DEFAULT Enhanced Mobile Phone Mode = Disable Enhanced Mobile Phone Mode = Enable Product Reference Guide...
  • Page 78: Decode Negative Image

    Negative Image bar code. NOTE When this feature is enabled, you will be unable to read other program- ming labels in this manual. CAUTION DEFAULT Decode Negative Image = Disable Decode Negative Image = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 79: Disable All Symbologies

    DISABLE ALL SYMBOLOGIES Use this feature to disable all symbologies. 1. Scan the ENTER/EXIT PROGRAMMING MODE barcode below. 2. Scan the Disable All Symbologies barcode. 3. Complete the programming sequence by scanning the ENTER/EXIT PRO- GRAMMING barcode. ENTER/EXIT PROGRAMMING MODE Disable All Symbologies This does not disable the reading of programming labels.
  • Page 80: 1D Symbologies

    Follett 2 of 5 on page 114 • Interleaved 2 of 5 CIP HR on page 114 • on page 115 TANDARD on page 119 NDUSTRIAL Code IATA on page 124 • on page 125 ATALOGIC DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 81 on page 129 ODABAR ABC Codabar on page 135 • on page 138 on page 142 GS1 D ™ O MNIDIRECTIONAL GS1 DataBar™ Omnidirectional on page 142 • GS1 DataBar™ Expanded on page 143 • GS1 DataBar™ Limited on page 147 •...
  • Page 82: Code Ean/Upc

    Coupon Control = Enable only GS1 DataBar™ coupon decoding UPC-A The following options apply to the UPC-A symbology. UPC-A Enable/Disable When disabled, the reader will not read UPC-A barcodes. UPC-A = Disable DEFAULT UPC-A = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 83: Upc-A Check Character Transmission

    Enter/Exit Programming Mode UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A barcode data. UPC-A Check Character Transmission = Don’t Send DEFAULT UPC-A Check Character Transmission = Send Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
  • Page 84: Upc-A Number System Character Transmission

    UPC-A Number System Character = Transmit UPC-E The following options apply to the UPC-E symbology. UPC-E Enable/Disable When disabled, the reader will not read UPC-E barcodes. UPC-E = Disable DEFAULT UPC-E = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 85: Upc-E Check Character Transmission

    Enter/Exit Programming Mode UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E barcode data. UPC-E Check Character Transmission = Don’t Send DEFAULT UPC-E Check Character Transmission = Send Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
  • Page 86: Expand Upc-E To Upc-A

    UPC-E to UPC-A = Expand UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number char- acter. UPC-E Number System Character = Do not transmit DEFAULT UPC-E Number System Character = Transmit DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 87: Gtin Formatting

    Enter/Exit Programming Mode GTIN FORMATTING This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14-character format. If add-on information is present on the base label prior to the conversion taking place, the add-on information will be appended to the converted GTIN label.
  • Page 88: Ean 13 (Jan 13)

    EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode data. EAN 13 Check Character Transmission = Don’t Send DEFAULT EAN 13 Check Character Transmission = Send DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 89: Ean-13 Isbn Conversion

    Enter/Exit Programming Mode EAN-13 ISBN Conversion This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels. DEFAULT EAN-13 ISBN Conversion = Disable EAN-13 ISBN Conversion = Convert to ISBN ISSN The following options apply to the ISSN symbology. ISSN Enable/Disable Enables/disables conversion of EAN/JAN13 Bookland labels starting with 977 to ISSN labels.
  • Page 90: Ean 8 (Jan 8)

    Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. DEFAULT Expand EAN 8 to EAN 13 = Disable Expand EAN 8 to EAN 13 = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 91: Upc/Ean Global Settings

    Enter/Exit Programming Mode UPC/EAN GLOBAL SETTINGS This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each fea- ture description. UPC/EAN Price Weight Check This feature enables/disables calculation and verification of price/weight check digits.
  • Page 92: Add-Ons

    Conditional add-on settings (if enabled) are considered by the NOTE reader before optional add-on settings. DEFAULT Optional Add-Ons = Disable P2 Optional Add-Ons = Enable P2 DEFAULT Optional Add-Ons = Disable P5 Optional Add-Ons = Enable P5 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 93: Optional Add-On Timer

    Enter/Exit Programming Mode Optional Add-On Timer This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled.) DEFAULT Optional Add-on Timer = 10ms Optional Add-on Timer = 20ms Optional Add-on Timer = 30ms Optional Add-on Timer = 40ms Optional Add-on Timer = 50ms...
  • Page 94: Disable All Symbologies

    2. Scan the Disable All Symbologies barcode. 3. Complete the programming sequence by scanning the ENTER/EXIT PRO- GRAMMING barcode. ENTER/EXIT PROGRAMMING MODE Disable All Symbologies This does not disable the reading of programming labels. NOTE DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 95 Enter/Exit Programming Mode Optional Add-On Timer (continued) Optional Add-on Timer = 60ms Optional Add-on Timer = 70ms Optional Add-on Timer = 100ms Optional Add-on Timer = 120ms Optional Add-on Timer = 140ms Optional Add-on Timer = 160ms Product Reference Guide...
  • Page 96 Optional Add-on Timer = 180ms Optional Add-on Timer = 200ms Optional Add-on Timer = 220ms Optional Add-on Timer = 240ms Optional Add-on Timer = 260ms Optional Add-on Timer = 280ms Optional Add-on Timer = 300ms DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 97: Code 39

    Enter/Exit Programming Mode CODE 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable Code 39 = Disable DEFAULT Code 39 = Enable Code 39 Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Code 39 check character.
  • Page 98: Code 39 Check Character Transmission

    Code 39 Check Character Transmission Enable this option to transmit the check character along with Code 39 barcode data. Code 39 Check Character Transmission = Don’t Send DEFAULT Code 39 Check Character Transmission = Send DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 99: Code 39 Start/Stop Character Transmission

    Enter/Exit Programming Mode Code 39 Start/Stop Character Transmission Enable this option to enable/disable transmission of Code 39 start and stop characters DEFAULT Code 39 Start/Stop Character Transmission = Don’t Transmit Code 39 Start/Stop Character Transmission = Transmit Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.
  • Page 100: Code 39 Quiet Zones

    Read the Enter/Exit Programming Mode bar code at the top of this page and then one of the following bar codes. DEFAULT Quiet zones = Auto Quiet Zones = Small Quiet Zones on two side DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 101: Code 39 Length Control

    Enter/Exit Programming Mode Code 39 Length Control This feature specifies either variable length decoding, fixed length decoding or no check length decoding for the Code 39 symbology. For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set.
  • Page 102: Code 39 Set Length 1

    Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Characters DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 103: Code 39 Set Length 2

    Enter/Exit Programming Mode Code 39 Set Length 2 This feature specifies one of the barcode lengths for Code 39. Length 2 is the maximum label length if in Variable Length on page 93 Mode, or the second fixed length if in Fixed Length on page 93 Mode.
  • Page 104: Code 39 Interdigit Ratio

    Code 39 Interdigit Ratio = Disable Code 39 Interdigit Ratio = 1 Code 39 Interdigit Ratio = 2 Code 39 Interdigit Ratio = 3 Code 39 Interdigit Ratio = 4 Code 39 Interdigit Ratio = 5 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 105 Enter/Exit Programming Mode Code 39 Interdigit Ratio (continued) Code 39 Interdigit Ratio = 6 Code 39 Interdigit Ratio = 7 Code 39 Interdigit Ratio = 8 Code 39 Interdigit Ratio = 9 Code 39 Interdigit Ratio = 10 Product Reference Guide...
  • Page 106: Code 32 (Ital Pharmaceutical Code)

    Code 32 Feature Setting Exceptions The following features are set for Code 32 by using these Code 39 settings: "Code 39 Length Control" on page 93 NOTE "Code 39 Interdigit Ratio" on page 96 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 107: Code 32 Check Char Transmission

    Enter/Exit Programming Mode Code 32 Check Char Transmission Enable this option to transmit the check character along with Code 32 barcode data. DEFAULT Code 32 Check Character Transmission = Don’t Send Code 32 Check Character Transmission = Send Code 32 Start/Stop Character Transmission This option enables/disables transmission of Code 32 start and stop charac- ters DEFAULT...
  • Page 108: Code 39 Cip (French Pharmaceutical)

    The following options apply to the Code 39 CIP symbology. Code 39 CIP Enable/Disable Enables/Disables ability of the reader to decode Code 39 CIP labels. DEFAULT Code 39 CIP = Disable Code 39 CIP = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 109: Code 128

    Enter/Exit Programming Mode CODE 128 The following options apply to the Code 128 symbology. Code 128 Enable/Disable When disabled, the reader will not read Code 128 barcodes. Code 128 = Disable DEFAULT Code 128 = Enable Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 barcode data.
  • Page 110: Code 128 Function Character Transmission

    10 times the width of the narrowest bar or space in the label. Code 128 Quiet Zones = No Quiet Zones DEFAULT Code 128 Quiet Zones = Auto DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 111: Code 128 Length Control

    Enter/Exit Programming Mode Code 128 Length Control This feature specifies either variable length decoding, fixed length decoding or no check length decoding for the Code 128 symbology. Code 128 Length Control = Variable Length Code 128 Length Control = Fixed Length DEFAULT Code 128 Length Control = No Check Product Reference Guide...
  • Page 112: Code 128 Set Length 1

    Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 113: Code 128 Set Length 2

    Enter/Exit Programming Mode Code 128 Set Length 2 This feature specifies one of the barcode lengths for Code 128. Length 2 is the maximum label length if in Variable Length on page 93 Mode, or the second fixed length if in Fixed Length on page 93 Mode.
  • Page 114: Gs1-128

    Transmit GS1-128 labels in GS1-128 data format. • Do not transmit GS1-128 labels. GS1-128 = Transmit in Code 128 data format DEFAULT GS1-128 = Transmit in GS1-128 data format GS1-128 = Do not transmit GS1-128 labels DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 115: Code Isbt 128

    Enter/Exit Programming Mode CODE ISBT 128 The following options apply to the ISBT 128 symbology. ISBT 128 Concatenation Use this option to enable/disable ISBT128 concatenation of 2 labels. DEFAULT ISBN 128 Concatenation = Disable ISBN 128 Concatenation = Enable ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic.
  • Page 116: Isbt 128 Dynamic Concatenation Timeout

    ISBT 128 Dynamic Concatenation Timeout = 750 msec ISBT 128 Dynamic Concatenation Timeout = 1 second ISBT 128 Advanced Concatenation Options To set up pairs of label types for concatenation, use the Datalogic Aladdin configura- tion application or contact Datalogic Technical Support. NOTE...
  • Page 117: Interleaved 2 Of 5 (I 2 Of 5)

    Enter/Exit Programming Mode INTERLEAVED 2 OF 5 (I 2 OF 5) The following options apply to the I 2 of 5 symbology. I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 barcodes. DEFAULT I 2 of 5 = Disable I 2 of 5 = Enable I 2 of 5 Check Character Calculation...
  • Page 118: I 2 Of 5 Check Character Transmission

    Enable this option to transmit the check character along with I 2 of 5 barcode data. I 2 of 5 Check Character Transmission = Don’t Send DEFAULT I 2 of 5 Check Character Transmission = Send DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 119: I 2 Of 5 Length Control

    Enter/Exit Programming Mode I 2 of 5 Length Control This feature specifies either variable length decoding, fixed length decoding or no check length decoding for the I 2 of 5 symbology. For variable length decoding, a minimum and maximum length Variable Length: may be set.
  • Page 120: I 2 Of 5 Set Length 1

    Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 06 = Length 1 is 6 Characters DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 121 Enter/Exit Programming Mode I 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for I 2 of 5 Length Control on page 111. Length 2 is the maximum label length if in Variable Length on page 93 Mode, or the second fixed length if in Fixed Length on page 93 Mode.
  • Page 122: Follett 2 Of 5

    Interleaved 2 of 5 CIP HR Enable/Disable Enables/Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels. DEFAULT Interleaved 2 of 5 CIP HR = Disable Interleaved 2 of 5 CIP HR = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 123: Standard 2 Of 5

    Enter/Exit Programming Mode STANDARD 2 OF 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 barcodes. DEFAULT Standard 2 of 5 = Disable Standard 2 of 5 = Enable Standard 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Stan-...
  • Page 124: Standard 2 Of 5 Length Control

    For fixed length decoding, two different lengths may be set. Fixed Length: Standard 2 of 5 Length Control = Variable Length Standard 2 of 5 Length Control = Fixed Length DEFAULT Standard 2 of 5 Length Control = No Check DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 125: Standard 2 Of 5 Set Length 1

    Enter/Exit Programming Mode Standard 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Standard 2 of 5. Length 1 is the minimum label length if in Variable Length on page 116 Mode, or the first fixed length if in Fixed Length on page 93 Mode.
  • Page 126: Standard 2 Of 5 Set Length 2

    Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 50 = Length 2 is 50 Characters DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 127: Industrial 2 Of 5

    Enter/Exit Programming Mode INDUSTRIAL 2 OF 5 The following options apply to the Industrial 2 of 5 symbology. Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode Industrial 2 of 5 labels. DEFAULT Industrial 2 of 5 = Disable Industrial 2 of 5 = Enable Product Reference Guide...
  • Page 128: Industrial 2 Of 5 Check Character Calculation

    Industrial 2 of 5 Check Character Transmission Enables/disables transmission of an Industrial 2 of 5 check character. Industrial 2 of 5 Check Character Transmission = Disable DEFAULT Industrial 2 of 5 Check Character Transmission = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 129: Industrial 2 Of 5 Length Control

    Enter/Exit Programming Mode Industrial 2 of 5 Length Control This feature specifies either variable length decoding, fixed length decoding or no check length decoding for the Industrial 2 of 5 symbology. For variable length decoding, a minimum and maximum length Variable Length: may be set.
  • Page 130: Industrial 2 Of 5 Set Length 1

    Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 06 = Length 1 is 6 Characters DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 131: Industrial 2 Of 5 Set Length 2

    Enter/Exit Programming Mode Industrial 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Industrial 2 of 5. Length 2 is the maximum label length if in Variable Length on page 93 Mode, or the second fixed length if in Fixed Length on page 93 Mode.
  • Page 132: Code Iata

    IATA = Enable IATA Check Character Transmission Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character. IATA Check Character Transmission = Disable DEFAULT IATA Check Character Transmission = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 133: Datalogic 2 Of 5

    DATALOGIC 2 OF 5 The following options apply to the Datalogic 2 of 5 symbology. Datalogic 2 of 5 Enable/Disable When disabled, the reader will not read Datalogic 2 of 5 barcodes. DEFAULT Datalogic 2 of 5 = Disable Datalogic 2 of 5 = Enable...
  • Page 134: Datalogic 2 Of 5 Length Control

    Enter/Exit Programming Mode Datalogic 2 of 5 Length Control This feature specifies either variable length decoding, fixed length decoding or no check length decoding for the Datalogic 2 of 5 symbology. For variable length decoding, a minimum and maximum length Variable Length: may be set.
  • Page 135: Datalogic 2 Of 5 Set Length 1

    Enter/Exit Programming Mode Datalogic 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Datalogic 2 of 5. Length 1 is the minimum label length if in Variable Length on page 111 Mode, or the first...
  • Page 136: Datalogic 2 Of 5 Set Length 2

    (only one fixed length). For more detailed programming instructions see "Set Length" on Chapter 4, References. Table 12 provides examples for setting Length 2. Table 12. Datalogic 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES Ignore This Desired Setting...
  • Page 137: Codabar

    Enter/Exit Programming Mode CODABAR The following options apply to the Codabar symbology. Codabar Enable/Disable When disabled, the reader will not read Codabar barcodes. DEFAULT Codabar = Disable Codabar = Enable Codabar Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Codabar check character.
  • Page 138: Codabar Check Character Transmission

    Codabar Check Character Transmission = Send Codabar Start/Stop Character Transmission Enable this option to enable/disable transmission of Codabar start and stop characters Codabar Start/Stop Character Transmission = Don’t Trans- DEFAULT Codabar Start/Stop Character Transmission = Transmit DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 139: Codabar Start/Stop Character Match

    Enter/Exit Programming Mode Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match DEFAULT Codabar Start/Stop Character Match = Don’t Require Match Codabar Start/Stop Character Match = Require Match Codabar Quiet Zones Specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the nar- rowest bar or space in the label.
  • Page 140: Codabar Length Control

    For fixed length decoding, two different lengths may be set. Fixed Length: Codabar Length Control = Variable Length Codabar Length Control = Fixed Length DEFAULT Codabar Length Control = No Check DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 141: Codabar Set Length 1

    Enter/Exit Programming Mode Codabar Set Length 1 This feature specifies one of the barcode lengths for Codabar. Length 1 is the minimum label length if in Variable Length on page 93 Mode, or the first fixed length if in Fixed Length on page 93 Mode.
  • Page 142: Codabar Set Length 2

    Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 143: Abc Codabar

    Enter/Exit Programming Mode ABC CODABAR The following options apply to the ABC Codabar symbology. ABC Codabar Enable/Disable Enables/Disables ability of reader to decode ABC Codabar labels. DEFAULT ABC Codabar = Disable ABC Codabar = Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic. DEFAULT ABC Codabar Concatenation Mode = Static ABC Codabar Concatenation Mode = Dynamic...
  • Page 144: Abc Codabar Dynamic Concatenation Timeout

    ABC Codabar Dynamic Concatenation Timeout = 200 msec ABC Codabar Dynamic Concatenation Timeout = 500 msec ABC Codabar Dynamic Concatenation Timeout = 750 msec ABC Codabar Dynamic Concatenation Timeout = 1 Second DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 145: Abc Codabar Force Concatenation

    Enter/Exit Programming Mode ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated. DEFAULT ABC Codabar Force Concatenation = Disable ABC Codabar Force Concatenation = Enable Product Reference Guide...
  • Page 146: Code 11

    Code 11 Check Character Calculation = Disable Code 11 Check Character Calculation = Check C Code 11 Check Character Calculation = Check K DEFAULT Code 11 Check Character Calculation = Check C and K DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 147: Code 11 Check Character Transmission

    Enter/Exit Programming Mode Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check char- acter. Code 11 Check Character Transmission = Don’t Send DEFAULT Code 11 Check Character Transmission = Send Code 11 Length Control This feature specifies either variable length decoding, fixed length decoding or no check length decoding for the Code 11 symbology.
  • Page 148: Code 11 Set Length 1

    Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 149: Code 11 Set Length 2

    Enter/Exit Programming Mode Code 11 Set Length 2 This feature specifies one of the barcode lengths for Code 11. Length 2 is the maximum label length if in Variable Length on page 93 Mode, or the second fixed length if in Fixed Length on page 93 Mode.
  • Page 150: Gs1 Databarâ„¢ Omnidirectional

    GS1 DataBar™ Omnidirectional GS1-128 Emulation When enabled, GS1 DataBar™ Omnidirectional barcodes will be translated to the GS1-128 label data format. DEFAULT GS1 DataBar™ Omnidirectional GS1-128 Emulation = Disable GS1 DataBar™ Omnidirectional GS1-128 Emulation = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 151: Gs1 Databarâ„¢ Expanded

    Enter/Exit Programming Mode GS1 DATABAR™ EXPANDED The following options apply to the GS1 DataBar™ Expanded (formerly RSS Expanded) symbology. GS1 DataBar™ Expanded Enable/Disable When disabled, the reader will not read GS1 DataBar™ Expanded barcodes. DEFAULT GS1 DataBar™ Expanded = Disable GS1 DataBar™...
  • Page 152: Gs1 Databarâ„¢ Expanded Length Control

    For fixed-length decoding, two different lengths may be set. Fixed Length. GS1 DataBar™ Expanded Length Control = Variable Length GS1 DataBar™ Expanded Length Control = Fixed Length DEFAULT GS1 DataBar™ Expanded Length Control = No check DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 153: Gs1 Databarâ„¢ Expanded Set Length 1

    Enter/Exit Programming Mode GS1 DataBar™ Expanded Set Length 1 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded. Length 1 is the minimum label length if in Variable Length on page 93 Mode, or the first fixed length if in Fixed Length on page 93 Mode.
  • Page 154: Gs1 Databarâ„¢ Expanded Set Length 2

    Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 74 = Length 2 is 74 Characters DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 155: Gs1 Databarâ„¢ Limited

    Enter/Exit Programming Mode GS1 DATABAR™ LIMITED The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology. GS1 DataBar™ Limited Enable/Disable When disabled, the reader will not read GS1 DataBar™ Limited barcodes. DEFAULT GS1 DataBar™ Limited = Disable GS1 DataBar™...
  • Page 156: Code 93

    Code 93 Check Character Calculation = Disable Code 93 Check Character Calculation = Enable Check C Code 93 Check Character Calculation = Enable Check K DEFAULT Code 93 Check Character Calculation = Enable Check C and K DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 157: Code 93 Check Character Transmission

    Enter/Exit Programming Mode Code 93 Check Character Transmission Enables/disables transmission of an optional Code 93 check character. DEFAULT Code 93 Check Character Transmission = Disable Code 93 Check Character Transmission = Enable Code 93 Length Control This feature specifies either variable length decoding, fixed length decoding or no check length decoding for the Code 93 symbology.
  • Page 158: Code 93 Set Length 1

    Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 159: Code 93 Set Length 2

    Enter/Exit Programming Mode Code 93 Set Length 2 This feature specifies one of the barcode lengths for Code 93. Length 2 is the maximum label length if in Variable Length on page 93 Mode, or the second fixed length if in Fixed Length on page 93 Mode.
  • Page 160: Code 93 Quiet Zones

    Enter/Exit Programming Mode Code 93 Quiet Zones Enables/disables quiet zones for Code 93. Code 93 Quiet Zones = No Quiet Zones DEFAULT Code 93 Quiet Zones = Auto DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 161: Msi

    Enter/Exit Programming Mode The following options apply to the MSI symbology. MSI Enable/Disable Enables/Disables ability of reader to decode MSI labels. DEFAULT MSI = Disable MSI = Enable MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check character.
  • Page 162: Msi Check Character Transmission

    For fixed length decoding, two different lengths may be Fixed Length: set. MSI Length Control = Variable Length MSI = Fixed Length DEFAULT MSI Length Control = No Check DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 163: Msi Set Length 1

    Enter/Exit Programming Mode MSI Set Length 1 This feature specifies one of the barcode lengths for MSI. Length 1 is the minimum label length if in Mode, or the first Variable Length on page 93 fixed length if in Mode. Length includes the bar- Fixed Length on page 93 code’s data characters only.
  • Page 164: Msi Set Length 2

    Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 165: Plessey

    Enter/Exit Programming Mode PLESSEY The following options apply to the Plessey symbology. Plessey Enable/Disable Enables/Disables ability of reader to decode Plessey labels. DEFAULT Plessey = Disable Plessey = Enable Product Reference Guide...
  • Page 166: Plessey Check Character Calculation

    Enable Plessey std. and Anker check char verification Plessey Check Character Transmission Enables/disables transmission of an MSI check character. Plessey Check Character Transmission = Disable DEFAULT Plessey Check Character Transmission = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 167: Plessey Length Control

    Enter/Exit Programming Mode Plessey Length Control This feature specifies either variable length decoding, fixed length decoding or no check length decoding for the Plessey symbology. For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: Plessey Length Control = Variable Length Plessey = Fixed Length...
  • Page 168: Plessey Set Length 1

    Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 169: Plessey Set Length 2

    Enter/Exit Programming Mode Plessey Set Length 2 This feature specifies one of the barcode lengths for Plessey Length Control on page 159. Length 2 is the maximum label length if in Variable Length on page 93 Mode, or the second fixed length if in Fixed Length on page 93 Mode.
  • Page 170: 2D Symbologies

    QR C • on page 201 QR C ICRO • on page 205 IGITAL ATERMARK • on page 206 • on page 207 UCC C OMPOSITE • on page 208 OSTAL ELECTION DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 171: Global Features

    2D Global Features The following features are common to all, or in some cases, most of the avail- able 2D symbologies. Default settings are indicated at each feature/option with a green arrow. To set most features: 1. Scan the ENTER/EXIT PROGRAMMING bar code at the top of applicable pro- gramming pages.
  • Page 172: Structured Append

    The structured append property is globally applied to the following symbologies, if these are enabled: • Aztec • Data Matrix • PDF 417 • QR Code DEFAULT Structured Append = Disable Structured Append = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 173: Normal/Inverse Symbol Control

    Enter/Exit Programming Mode 2D Normal/Inverse Symbol Control Specifies the options available for decoding normal/negative printed 2D sym- bols. This configuration item applies globally to all the 2D symbologies that support that feature according to Standard AIM Specification: Data Matrix, QR, MicroQR, Aztec and Han Xin Code .
  • Page 174: Symbology Selection

    Enter/Exit Programming Mode 2D Symbology Selection AZTEC CODE Aztec Code Enable / Disable Enables/disables the ability of the reader to decode Aztec Code labels. DEFAULT Aztec Code = Disable Aztec Code = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 175: Aztec Code Length Control

    Enter/Exit Programming Mode Aztec Code Length Control This feature specifies either variable length decoding, fixed length decoding or no check length decoding for this symbology. For variable length decoding, a minimum and maximum length Variable Length. may be set. For fixed length decoding, two different lengths may be set. Fixed Length.
  • Page 176: Aztec Code Set Length 1

    Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 0001 = Length 1 is 1 Character DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 177: Aztec Code Set Length 2

    Enter/Exit Programming Mode Aztec Code Set Length 2 This feature specifies one of the bar code lengths for Aztec Code. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,832 char- acters in increments of 0001 (pad with zeroes).
  • Page 178: Han Xin Code

    HAN XIN CODE Han Xin Code Enable / Disable Enables/disables the ability of the reader to decode Han Xin Code labels. DEFAULT Han Xin Code = Disable Han Xin Code = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 179: Han Xin Code: Code Length Control

    Enter/Exit Programming Mode Han Xin Code: Code Length Control This feature specifies either variable length decoding, fixed length decoding or no check length decoding for this symbology. For variable length decoding, a minimum and maximum length Variable Length. may be set. For fixed length decoding, two different lengths may be set.
  • Page 180: Han Xin Code Set Length 1

    Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 0001 = Length 1 is 1 Character DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 181: Han Xin Code Set Length 2

    Enter/Exit Programming Mode Han Xin Code Set Length 2 This feature specifies one of the bar code lengths for Han Xin Code. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,827 char- acters in increments of 0001 (pad with zeroes).
  • Page 182: Data Matrix

    Enter/Exit Programming Mode DATA MATRIX Data Matrix Enable / Disable Enables/disables ability of reader to decode Data Matrix labels. Data Matrix = Disable DEFAULT Data Matrix = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 183: Data Matrix Square/Rectangular Style

    Enter/Exit Programming Mode Data Matrix Square/Rectangular Style Specifies the options available when reading Data Matrix with different form factors. Choices are: • Square Style • Rectangular Style • Both Square and Rectangular Style The configuration item can also be configured as a bit mask to filter one or more Data Matrix labels with different symbol size AND shape styles.
  • Page 184: Data Matrix Length Control

    For fixed length decoding, two different lengths may be set. Fixed Length. Data Matrix Length Control = Variable Length Data Matrix Length Control = Fixed Length DEFAULT Data Matrix Length Control = No Check DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 185: Disable All Symbologies

    Enter/Exit Programming Mode DISABLE ALL SYMBOLOGIES Use this feature to disable all symbologies. 1. Scan the ENTER/EXIT PROGRAMMING MODE barcode below. 2. Scan the Disable All Symbologies barcode. 3. Complete the programming sequence by scanning the ENTER/EXIT PRO- GRAMMING barcode. ENTER/EXIT PROGRAMMING MODE Disable All Symbologies This does not disable the reading of programming labels.
  • Page 186: Data Matrix Set Length 1

    Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 0001 = Length 1 is 1 Character DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 187: Data Matrix Set Length 2

    Enter/Exit Programming Mode Data Matrix Set Length 2 This feature specifies one of the bar code lengths for Data Matrix. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,116 char- acters in increments of 0001 (pad with zeroes).
  • Page 188: Dotcode

    For fixed length decoding, two different lengths may be set. Fixed Length. DotCode Length Control = Variable Length DotCode Length Control = Fixed Length DEFAULT DotCode Length Control = No Check DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 189: Dotcode Set Length 1

    Enter/Exit Programming Mode DotCode Set Length 1 Specifies one of the bar code lengths for DotCode. Length 1 is the minimum label length if in Variable Length on page 180, or the first fixed length if in Fixed Length on page 180.
  • Page 190: Dotcode Set Length 2

    Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 7000 = Length 2 is 7000 DEFAULT Characters DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 191: Dotcode High Resolution

    Enter/Exit Programming Mode DotCode High Resolution Enables or disables the high resolution configuration for detecting codes. Use- ful for decoding high resolution DotCode. DEFAULT DotCode High Resolution = Disable DotCode High Resolution = Enable DotCode Constant Position Enables or disables a mode useful for decoding a series of DotCodes that will be presented in about the same area of the field of view.
  • Page 192: Dotcode Maximum Dot Diameter

    Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 0016 = Maximum Dot Diameter is 16 pixels DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 193: Dotcode Minimum Dot Diameter

    Enter/Exit Programming Mode DotCode Minimum Dot Diameter This feature specifies the minimum dot diameter of a DotCode to be decoded: the measurement unit is pixel and it refers to the diameter of the dots as they appear on the acquired image. Characters can be set from 0001 to 0512 in increments of 1 (pad with zeroes).
  • Page 194: Maxicode

    Maxicode Primary Message Transmission Enables/disables the transmission of only the Primary Message when the Secondary Message is not readable. DEFAULT Maxicode Primary Message Transmission = Disable Maxicode Primary Message Transmission = Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 195: Maxicode Length Control

    Enter/Exit Programming Mode Maxicode Length Control This feature specifies either variable length decodin, fixed length decoding or no check length decoding for this symbology. For variable length decoding, a minimum and maximum length Variable Length. may be set. For fixed length decoding, two different lengths may be set. Fixed Length.
  • Page 196: Maxicode Set Length 1

    Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 0001 = Length 1 is 1 Character DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 197: Maxicode Set Length 2

    Enter/Exit Programming Mode Maxicode Set Length 2 This feature specifies one of the bar code lengths for Maxicode. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0138 characters in increments of 0001 (pad with zeroes).
  • Page 198: Pdf417

    For fixed length decoding, two different lengths may be set. Fixed Length. PDF417 Length Control = Variable Length PDF417 Length Control = Fixed Length DEFAULT PDF417 Length Control = No Check DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 199: Pdf417 Set Length 1

    Enter/Exit Programming Mode PDF417 Set Length 1 Specifies one of the bar code lengths for PDF417. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. Characters can be set from 0001 to 2,710 characters (pad with zeroes) in increments of 01.
  • Page 200: Pdf417 Set Length 2

    Select PDF417 Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL Length 2 is 2,710 Characters DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 201: Micro Pdf417

    Enter/Exit Programming Mode MICRO PDF417 Micro PDF417 Enable / Disable Enables/disables the ability of the reader to decode Micro PDF417 labels DEFAULT Micro PDF417 = Disable Micro PDF417 = Enable Product Reference Guide...
  • Page 202: Micro Pdf417 Code 128 Gs1-128 Emulation

    • Code 128 / EAN128 AIM Id and label type DEFAULT Micro PDF417 Code 128 GS1-128 Emulation = Micro PDF AIM ID and label type Micro PDF417 Code 128 GS1-128 Emulation = Code 128 / EAN128 AIM ID and label type DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 203: Micro Pdf417 Length Control

    Enter/Exit Programming Mode Micro PDF417 Length Control This feature specifies either variable length decoding, fixed length decoding or no check length decoding for this symbology. For variable length decoding, a minimum and maximum length Variable Length. may be set. For fixed length decoding, two different lengths may be set. Fixed Length.
  • Page 204: Micro Pdf417 Set Length 1

    Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 0001 = Length 1 is 1 Character DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 205: Micro Pdf417 Set Length 2

    Enter/Exit Programming Mode Micro PDF417 Set Length 2 This feature specifies one of the bar code lengths for Micro PDF417. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length includes the bar code’s data characters only. Charac- ters can be set from 0001 to 0366 characters (pad with zeroes) in increments of 01.
  • Page 206: Qr Code

    For fixed length decoding, two different lengths may be set. Fixed Length. QR Code Length Control = Variable Length QR Code Length Control = Fixed Length DEFAULT QR Code Length Control = No Check DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 207: Qr Code Set Length 1

    Enter/Exit Programming Mode QR Code Set Length 1 Specifies one of the bar code lengths for QR Code Length Control on page 198. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,089 characters in increments of 0001 (pad with zeroes).
  • Page 208: Qr Code Set Length 2

    Select QR Code Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL Length 2 is 7,089 Characters DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 209: Micro Qr Code

    Enter/Exit Programming Mode MICRO QR CODE Micro QR Code Enable/Disable Enables/disables the ability of the reader to decode Micro QR Code labels DEFAULT Micro QR Code = Disable Micro QR Code = Enable Product Reference Guide...
  • Page 210: Micro Qr Code Length Control

    For fixed length decoding, two different lengths may be set. Fixed Length. Micro QR Code Length Control = Variable Length Micro QR Code Length Control = Fixed Length DEFAULT Micro QR Code Length Control = No Check DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 211: Micro Qr Code Set Length 1

    Enter/Exit Programming Mode Micro QR Code Set Length 1 Specifies one of the bar code lengths for Micro QR Code. Length 1 is the mini- mum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 212: Micro Qr Code Set Length 2

    Select Micro QR Code Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL Length 2 is 0035 Characters DEFAULT DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 213: Digital Watermark

    Enter/Exit Programming Mode DIGITAL WATERMARK Enables or disables the capability to decode images including Digimarc® digital watermark technology. When enabling Digimarc, also make sure to have enabled the EAN 13, EAN 8, UPC-A, UPC-E, CODE 128, GS1-128 and GS1 DataBar™ Expanded symbologies. For additional details and configuration options please contact technical support for assistance.
  • Page 214: Ocr

    Enter/Exit Programming Mode Enables or disables the Optical Character Recognition (OCR) capability of the decoder. For additional details and configuration options please contact techni- cal support for assistance. DEFAULT OCR Disable OCR Enable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 215: Ucc Composite

    Enter/Exit Programming Mode UCC COMPOSITE UCC Optional Composite Timer Specifies the amount of time the system will wait for the stacked part of a UCC Composite label before transmitting the linear label without an add-on. DEFAULT UCC Optional Composite Timer = Timer Disabled UCC Optional Composite Timer = 100msec UCC Optional Composite Timer = 200msec UCC Optional Composite Timer = 300msec...
  • Page 216: Postal Code Selection

    PostNet BB • Australian Post • NewZealand Postal • Japanese Post PostNet = Enable DEFAULT PostNet = Disable PlaNet = Enable DEFAULT PlaNet = Disable RoyalMail = Enable DEFAULT RoyalMail = Disable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 217 Enter/Exit Programming Mode Postal Code Selection (continued) Kix = Enable DEFAULT Kix = Disable Australian Post = Enable DEFAULT Australian Post = Disable Japanese Post = Enable DEFAULT Japanese Post = Disable Product Reference Guide...
  • Page 218 Enter/Exit Programming Mode Postal Code Selection (continued) IMB Post = Enable DEFAULT IMB Post = Disable Swedish Postal = Enable DEFAULT Swedish Postal = Disable Portugal Post = Enable DEFAULT Portugal Post = Disable DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 219: Postnet Bb Control

    Enter/Exit Programming Mode Postnet BB Control Controls the ability of the scanner to decode B and B' fields of Postnet labels. PostNet BB = Enable DEFAULT PostNet BB = Disable NewZealand Postal Control Controls the ability of the scanner to decode NewZealand Postal labels. NewZealand Postal = Enable DEFAULT NewZealand Postal = Disable...
  • Page 220 NOTES DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 221: References

    Chapter 4 References This section contains explanations and examples of selected bar code features. Configuration Using Bar Codes on page 15 for the actual bar code labels used to configure the scanner. on page 214 RS-232 P ARAMETERS RS-232 Only on page 214 •...
  • Page 222: Parameters

    RTS — RTS is asserted during transmissions. CTS is ignored. • RTS/CTS — RTS is asserted during transmissions. CTS gates transmis- sions. • RTS On/CTS — RTS is always asserted. CTS gates transmissions. DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 223: Data Format

    Data Format Data Format Data Editing When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a “message string.” The Data Editing features can be used to build specific user-defined data into a message string.
  • Page 224: Global Prefix/Suffix

    ENTER/EXIT bar code to terminate the string. 5. Scan the ENTER/EXIT bar code once again to exit Programming Mode. 6. The resulting message string would appear as follows: Scanned bar code data: 12345 Resulting message string output: $12345 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 225: Global Aim Id

    Data Format Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. NOTE AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. AIM label identifiers consist of three characters as follows: •...
  • Page 226: Scanning Features

    IMPORTANT: Always On mode is not recommended for continuous and prolonged operations. Use Stand Mode (Automatic - Object Sense.). If you use Always On mode, make sure that DSM0400 is installed and mounted in the correct way for heat dissipation (e.g.:metal brackets or CAUTION supports are recommended.)
  • Page 227: Flash On Time

    Scanning Features Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1.
  • Page 228: Flash Off Time

    Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT FLASH OFF TIME SETTING Scan Two Characters From ‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’ ‘9’ and ‘9’ Appendix C Scan ENTER/EXIT PROGRAMMING MODE DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 229: Symbologies

    Symbologies Symbologies Set Length Length Control allows you to select either variable length decoding or fixed length decoding for the specified symbology. For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: Set Length 1 This feature specifies one of the bar code lengths for a given symbology.
  • Page 230: Set Length 2

    Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT LENGTH 2 SETTING Scan Two Characters From ‘0’ and ‘0’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ and ‘4’ Appendix C Scan ENTER/EXIT PROGRAMMING MODE DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 231: Technical Specifications

    Appendix A Technical Specifications Technical Features Item Description Physical Characteristics Color Black Height 27mm Dimensions Length 38mm Width 47mm USB version - Approximately 131 g Weight (with cable, without RS-232 version - Approximately 155 g bracket) RJ45 version - Approximately 96g Electrical Characteristics Input Voltage 5 VDC ±...
  • Page 232 All standard 1D codes including: UPC/EAN/JAN, P2 /P5 add-ons; Code 39; Italian Pharmacode 39; Code 128; C128 ISBT; I 2 of 5; Standard 2 of 5; Interleaved 2 of 5; Industrial 2of 5; Datalogic 2of5; IATA; Code 11; Codabar; ABC Codabar; EAN 128; Code 93; MSI/Plessey; RSS-14; BC412; Databar Limited;...
  • Page 233: Dsm04X1 Models (Wvga)

    Technical Features DSM04X1 models (WVGA) Resolution: 752x480 Field of View: 40°H x 26°V Typical Depth of Field Resolution (mils) Dmin (mm) Dmax (mm) Symbology Code 39 Code 39 EAN13 Datamatrix Code 39 a. All labels grade A, ambient light level 300lux, pitch angle 10°, tilt angle 10°, skew angle 0°, room temperature 20°C.
  • Page 234: Dsm04X2-Wa Models (Mp)

    External Trigger (DSM045X models only) Figure 1 - DSM0400 powered using DB9 pin n°6 and Input Trigger using DB9 pin n°1 Figure 2 - DSM0400 Input Trigger using DB9 pin n°1 with an external voltage Vext Acceptable range: from 1V to 5 V).
  • Page 235: Led And Beeper Indications

    The reader's beeper sounds and its LED illuminates to indicate various func- tions or errors on the reader. DSM0400 also projects “Green Spot” on the field of view when the “GOOD” green LED turns on. The following tables list these indications.
  • Page 236: Troubleshooting

    Bar code is decoded but not Imager not programmed for Scan the appropriate host type bar transmitted to the host. the correct host type. code. DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 237: Dsm0400 Dimensions

    DSM0400 Dimensions DSM0400 Dimensions Product Reference Guide...
  • Page 238: Multi-Face Bracket For Mounting In 5 Sides

    Technical Specifications Multi-face Bracket for Mounting in 5 sides DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 239: Angular Mounting Bracket

    DSM0400 Dimensions Angular Mounting Bracket -17° to +25° Possible Angle Product Reference Guide...
  • Page 240: Ergonomic Recommendations

    Perform tasks at correct heights • Reduce or eliminate vibration • Reduce or eliminate direct pressure • Provide adjustable workstations • Provide adequate clearance • Provide a suitable working environment • Improve work procedures. DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 241: Standard Cable Pinouts For Dsm049X Models

    Table 1. Standard Cable Pinouts — Scanner Side RS-232 RTS (out) CTS (in) IMPORTANT: DSM049X has to be used only with the Datalogic RS-232 or USB Cables indicated in the accessories list. NOTE Product Reference Guide...
  • Page 242 Technical Specifications NOTES DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 243: Sample Bar Codes

    Appendix B Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types. 1D Bar Codes UPC-A EAN-13 9780330290951 Code 39 Code 128 Code 128 Interleaved 2 of 5 Product Reference Guide...
  • Page 244: 1D Bar Codes - Continued

    Sample Bar Codes 1D Bar Codes - continued Code 32 345678902 Codabar 13579 Code 93 ABCDEF Code 11 123456779 DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 245: Gs1 Databarâ„¢ (Rss)

    GS1 DataBar™ (RSS) GS1 DataBar™ (RSS) GS1 DataBar™ variants must be enabled to read the bar codes below (see DataBar™ Omnidirectional" on page 142 NOTE GS1 DataBar™ Expanded Stacked 10293847560192837465019283746029478450366523 GS1 DataBar™ Expanded 1234890hjio9900mnb GS1 DataBar™ Limited 08672345650916 GS1 DataBar™-14 GS1 DataBar™...
  • Page 246: 2D Bar Codes

    Sample Bar Codes 2D Bar Codes Aztec Datamatrix China Sensible Code MaxiCode Test Message PDF 417 Micro PDF 417 PDF417 Car Registration BV17453 ABCabc QR Code Micro QR Code 123456 35900G9 UCC Composite DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 247: Ascii Chart

    ASCII Chart ASCII Chart ASCII ASCII ASCII ASCII Char. Char. Char. Char. ‘ “ & ’ < > Product Reference Guide...
  • Page 248 Sample Bar Codes NOTES DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 249: Keypad

    Appendix C Keypad Use the barcodes in this appendix to enter numbers as you would select dig- its/characters from a keypad. Product Reference Guide...
  • Page 250 Keypad DSM0400 Fixed Mount Area Imager Bar Code Reader...
  • Page 251: Hid Variable Pin Code

    HID Variable PIN Code HID Variable PIN Code Cancel an incomplete HID Variable PIN Code Exit HID Variable PIN Code Product Reference Guide...
  • Page 252 ©2020 Datalogic S.p.A. and/or its affiliates. All rights reserved. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S. and the E.U. Datalogic S.r.l. Via S. Vitalino, 13 Calderara di Reno 40012...

Table of Contents