GENERAL TECHNICAL INFORMATION
Contact 1, Contact 2
These are two contacts providing for engine disable, piloted
both by the immobilizer and by the engine control logic.
These contacts shall be properly sized for a loop current
equal to 200 mA, while current at start-up is 500 mA and
should be protected to allow inductive loads piloting.
Starter relay actuation
Shall be able to pilot a relay with maximum current of 4A.
DESIGN REQUIREMENTS
Operating conditions
Nominal voltage: 13.5±0.5 V
Operating voltage (not calibrated): 6V÷18V (it is in any
case necessary to ensure data storage in case of
temporary power failure such as upon start-up with flat
battery).
Operating voltage (calibrated): 9÷16 V
Absorption with key not inserted (excluded immobilizer
led, where fitted): <1mA
Operating temperature (not calibrated): -20°C ÷ +85°C
Operating temperature (calibrated): -18°C ÷+65°C
Stocking temperature: -30°C ÷ +90°C
Materials with slow combustion, resistant to fire as per
UL94-HB V2 standard.
Vehicle mission profile
Forecast life-span shall not be shorter than 50000 km or 8
years.
LCD Specifications
The display has a resolution of 128x112 pixel (X-axis - Y-
axis), the visible area is 62x55mm while active area (the one
actually covered by pixels) is 56x49 mm (X-axis - Y-axis).
Display cone is: On the horizontal surface (x-z) it is +45° -
45°, on the vertical surface (y-z) it is +10° -30°. The contrast
shall be more than 5 in the whole display cone.
All LCD shall be legible with Polaroid glasses up to 35° with
respect to the horizontal line.
Display temperatures
The display operating temperature specifications are the
following:
Operating temperature (with no ghost effect): -20°C ÷
+85°C
Stocking temperature: -30°C ÷ +90°C
The instrument panel shall therefore implement a display
compensation system upon ambient temperature variation.