Anw-Meld" Message - Siemens SIMATIC Ident RF200 Operating Manual

Ascii protocol
Hide thumbs Also See for SIMATIC Ident RF200:
Table of Contents

Advertisement

Address
Byte 14
Byte 15
Byte 16
Byte 17
Byte 18
Byte 19
Byte 20
Byte 21
The RESET command can be sent to the reader at any time to initialize the parameters.
Table 2- 17
"RESET" acknowledgment
Address
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
Bytes 10..11
2.10

"ANW-MELD" message

Table 2- 18
"ANW-MELD" message
Address
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
Designation
mtag
Fcon
Ftim
Designation
Frame length
Command
Status
Firmware version
Reserved
Designation
Frame length
Command
Status
Value
0x30
0x30
0x30
0x31
0x30
0x30
0x30
0x31
Value
0x30
0x35
0x30
0x30
high nibble
low nibble
xx, high nibble
xx, low nibble
yy, high nibble
yy, low nibble
0x30
Value
0x30
0x34
0x30
0x46
0x30
0x30
Command and message frames
2.10 "ANW-MELD" message
Description
Only single tag mode is supported
Reserved
ISO mode general
Description
Net data length of the frame - 1
byte
--
Error code "error_Moby"
Firmware version
Format: xx.yy
--
Description
Net data length of the frame - 1
byte
New command
--