Slg Status (Mode 1) Command - Siemens SIMATIC Ident RF200 Operating Manual

Ascii protocol
Hide thumbs Also See for SIMATIC Ident RF200:
Table of Contents

Advertisement

Address
Byte 8
Byte 9
Byte 10
Byte 11
2.5

SLG STATUS (mode 1) command

Table 2- 8
SLG STATUS (mode 1) command
Address
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
Byte 10
Byte 11
Byte 12
Byte 13
Table 2- 9
"SLG STATUS" (mode 1) acknowledgment
Address
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
Designation
Command status
Presence
Designation
Frame length
Command
Status
Mode
Reserve
Reserve
Reserve
Designation
Frame length
Command
Status
S-Info
Hardware
2.5 SLG STATUS (mode 1) command
Value
0x30
0x30 / 0x31
0x30
0x30 / 0x31
Value
0x30
0x36
0x30
0x34
0x30
0x30
0x30
0x31
0x30
0x30
0x30
0x30
0x30
0x30
Value
0x31
0x42
0x30
0x34
high nibble
low nibble
0x30
0x31
0x33
Command and message frames
Description
0x30 ≙ command is not active
0x31 ≙ command is active
0x30 ≙ no presence
0x31 ≙ presence
Description
Net data length of the frame - 1
byte
--
--
Mode 1
--
--
--
Description
Net data length of the frame - 1
byte
--
Error code "error_Moby"
Mode from command
Hardware version (reader)
13