Battery status indication

¸
The red LED
provide information on the (remaining) battery capacity.
¸

Changing the microphone module

First remove the battery and leave the radiomicrophone open.
Unscrew the sound inlet basket.
Remove the screw and put it to one side.
Remove the microphone module by using a flat-head
screwdriver at the end of the module (next to the screw hole) to
gently ease the capsule out of the contacts and then pull it out
of the housing as shown. Do not touch the contacts!
Insert the new module, secure the capsule by tightening the
screw, put on the sound inlet basket and coloured identification
ring supplied with the new module (NB: do NOT use the old
basket, as the different heads use slightly differing internal
foam) and screw it tight.
Insert the battery, close the radiomicrophone and put it into
operation.
Note:
Microphone module, sound inlet basket and foam insert form an
acoustic unit and must therefore always be exchanged all
together.

Care and maintenance

The radiomicrophone's sound inlet basket should be cleaned from
time to time.
Unscrew the inlet basket (turn counter-clockwise) and remove it.
Use a damp cloth to clean the inlet basket from the inside and
outside.
Note:
Do not use any cleansing agents or solvents. Do not touch the
microphone's contacts.
Replace the inlet basket on the radiomicrophone and screw it
tight (taking care not to loose the coloured identification ring).