  • Page 1 Configuration Manual SIMATIC NET Industrial Ethernet Switches RUGGEDCOM APE1808 For APE1808, APE1808W10 Edition 11/2019 https://www.siemens.com...
  • Page 2 Preface Overview Configuring and Using the RUGGEDCOM APE1808 SIMATIC NET Frequently Asked Questions Industrial Ethernet Switches RUGGEDCOM APE1808 Configuration Manual For APE1808, APE1808W10 11/2019 C79000-G8976-1415-03...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Table of Contents Preface ............................v Related Documents ......................... v Training ..........................vi Customer Support ........................vi Overview ..........................1 Operating System ....................1 Requirements and Restrictions ................3 Security Recommendations ................... 3 Operating Temperature Range and Behavior ............5 Rebooting/Powering Down the RUGGEDCOM APE1808 Module ......
  • Page 5 Table of Contents RUGGEDCOM APE1808 Configuration Manual, 11/2019, C79000-G8976-1415-03...
  • Page 6: Preface

    Note Documents listed are those available at the time of publication. Newer versions of these documents or their associated products may be available. For more informa- tion, visit SIOS or consult a Siemens Customer Support representative. Catalogs Document Title Link RUGGEDCOM RX1500 Modules Catalog https://support.industry.siemens.com/cs/ww/en/-...
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8 Preface Customer Support • Ask questions or share knowledge with fellow Siemens customers and the support community RUGGEDCOM APE1808 Configuration Manual, 11/2019, C79000-G8976-1415-03...
  • Page 9 Preface Customer Support viii RUGGEDCOM APE1808 Configuration Manual, 11/2019, C79000-G8976-1415-03...
  • Page 10: Overview

    Overview The RUGGEDCOM APE1808 (Application Processing Engine) is an x64-based comput- er designed to occupy a single line module slot in a RUGGEDCOM RX15xx device. The RUGGEDCOM APE1808 can host a variety of x64-based operating systems and fea- tures Gigabit Ethernet, USB ports and a Display port. The following RUGGEDCOM APE1808 modules are available: •...
  • Page 11 SD card. Other Software/Applications Siemens does not support any software installed on the RUGGEDCOM APE1808. This includes, but is not limited to, software images provided by Siemens Customer Sup- port. Linux and SD Card Support By default, the Linux-based version of the RUGGEDCOM APE1808 does not support SDXC or SDUC microSD cards (i.e.
  • Page 12: Requirements And Restrictions

    Security advisories that include links to applications are available on the Industrial Security website [http://www.indus- try.siemens.com/topics/global/en/industrial-security/news-alerts/Pages/alerts.as- or the ProductCERT Security Advisories website [http://www.siemens.com/in- novation/en/technology-focus/siemens-cert/cert-security-advisories.htm]. Up- dates to Siemens Product Security Advisories can be obtained by subscribing to RUGGEDCOM APE1808 Configuration Manual, 11/2019, C79000-G8976-1415-03...
  • Page 13 Overview 1.3 Security Recommendations the RSS feed on the Siemens ProductCERT SSecurity Advisories website, or by fol- lowing @ProductCert on Twitter. • Only enable the services that will be used on the module, including physical ports. Unused physical ports could potentially be used to gain access to the net- work behind the module.
  • Page 14: Operating Temperature Range And Behavior

    Periodically audit the module to make sure it complies with these recommenda- tions and/or any internal security policies. • Review the user documentation for other Siemens products used in coordination with RUGGEDCOM APE1808 for further security recommendations. Operating Temperature Range and Behavior The RUGGEDCOM APE1808 is rated for operation within the temperature range of -40 to 75 °C (-40 to 167 °F).
  • Page 15: Default Ip Addresses

    Overview 1.7 Default IP Addresses interface. Typical port parameters for the internal interface, such as speed, duplex, VLANs, and more, can be configured via RUGGEDCOM ROX II. NOTICE Interface settings configured via RUGGEDCOM ROX II must be mirrored within the RUGGEDCOM APE1808 module. For instance, if a VLAN is assigned to the module in RUGGEDCOM ROX II, a corresponding VLAN must also be configured via the mod- ule's operating system.
  • Page 16: Ruggedcom Ape1808 Ethernet And Network Settings

    Overview 1.8  RUGGEDCOM APE1808 Ethernet and Network Settings RUGGEDCOM APE1808 Ethernet and Network Settings The RUGGEDCOM APE1808 is essentially a two-port industrial computer. When the RUGGEDCOM APE1808 is inserted into a chassis, the first internal Ethernet port is activated on the connector that carries power to to the RUGGEDCOM APE1808. The second RUGGEDCOM APE1808 Ethernet port is available for use on the faceplate of the RUGGEDCOM APE1808 line module.
  • Page 17: Example: Rx15Xx Services And Wan Networking

    Overview 1.8.2 Example: RX15xx Services and WAN Networking user or automatically by a pre-configured DHCP server, to allow it to communicate on VLAN1. It has also been assigned a unique subnet to its ETH1 port. The RUGGEDCOM APE1808 can also access services and network management of the RUGGEDCOM RX1500 control module at its 192.168.0.2 address.
  • Page 18 Overview 1.8.2 Example: RX15xx Services and WAN Networking Figure 1.4 Example Configuration In this scenario, the RUGGEDCOM APE1808 is reached via a routed interface. This is accomplished by moving the RUGGEDCOM APE1808 port onto its own VLAN, and creating a point-to-point connection between it and the control module. The figure shows six serial ports available on serial LM 3.
  • Page 19 Overview 1.8.2 Example: RX15xx Services and WAN Networking RUGGEDCOM APE1808 Configuration Manual, 11/2019, C79000-G8976-1415-03...
  • Page 20: Configuring And Using The Ruggedcom Ape1808

    Configuring and Using the RUGGEDCOM APE1808 The following sections describe how to configure and use the RUGGEDCOM APE1808: NOTICE Before using the RUGGEDCOM APE1808, create a backup image that can be restored should the module be configured improperly. Warranty does not support modules rendered inoperable/inaccessible due to config- uration errors made by the user.
  • Page 21: Setting The Root And User Passwords (Linux Only)

    Configuring and Using the RUGGEDCOM APE1808 2.3 Setting the Root and User Passwords (Linux Only) Follow the instructions provided to complete the user profile. For example: root@wheezyape:~# adduser admin Adding user `admin' ... Adding new group `admin' (1000) ... Adding new user `admin' (1000) with group `admin' ... Creating home directory `/home/admin' ...
  • Page 22: Disabling Alternative Boot Options

    2.5 Disabling Alternative Boot Options To set the BIOS password, do the following: NOTICE If the BIOS password is lost, the module must be returned to Siemens for service. For more information, contact Siemens Customer Support. This service is not supported by warranty.
  • Page 23: Setting The Grub Bootloader Password

    Configuring and Using the RUGGEDCOM APE1808 2.6 Setting the GRUB Bootloader Password Setting the GRUB Bootloader Password To set the GRUB bootloader password, do the following: NOTICE Use strong passwords. Avoid weak passwords such as password1, 123456789, abcdefgh, etc. Login or gain root access. Create the GRUB bootloader password by typing: grub-mkpasswd-pbkdf2 Type the new password when requested.
  • Page 24: Setting The Hard Drive Password

    Configuring and Using the RUGGEDCOM APE1808 2.7 Setting the Hard Drive Password Setting the Hard Drive Password On Windows 10 Enterprise 2019 LTSC, BitLocker can be used to password-encrypt the hard drive. There is no pre-installed applications to password-encrypt the hard drive on Linux.
  • Page 25 If the syslog contains no messages reflecting an improper boot of the RUGGEDCOM APE1808, return the RUGGEDCOM APE1808 to Siemens. The RUGGEDCOM APE1808 should be returned to Siemens if its power LEDs remain dark and all above debugging steps have been performed.
  • Page 26: Frequently Asked Questions

    APE1808 before it is configured. If this image is available, it can be easily re- stored. If an original backup image is not available, contact Siemens Customer Support for assistance. In most cases, the RUGGEDCOM APE1808 module must be re- turned to the factory to be re-imaged.
  • Page 27 Frequently Asked Questions RUGGEDCOM APE1808 Configuration Manual, 11/2019, C79000-G8976-1415-03...
  • Page 28 Further Information Siemens https://www.siemens.com Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

This manual is also suitable for:

Simatic net ruggedcom ape1808w10

Table of Contents