  • Page 1 User manual PG 102 Rev 03 Editi 03 12 15 Pressotherapy model Power-Q1000 Premium...
  • Page 2 I.A.C.E.R. Srl Via S. Pertini 24/A – 30030 Martellago (VE) ITALY Tel. 041.5401356 • Fax 041.5402684 e-mail: iacer@iacer.it http://www.itechmedicaldivision.com...
  • Page 3 MDD 93/42/EEC Compliance...
  • Page 4: Table Of Contents

    Summary Summary Pressotherapy Machine body Graphic display detail Accessories Accessories size Configurations Specifications Technical Specifications Purpose Working instructions Warnings Cleaning Disposal Assistance Spare parts Warranty IACER SRL Page 4 di 24 MNPG102-02 30/07/15...
  • Page 5: Pressotherapy

    Pressotherapy Compressive limbs therapy is able to promote a right venous circulation by decreasing muscle tension caused by stress or chronic and acute pains: thanks to its pump action it favorites venous return by increasing tissues blood circulation and finally their physiological renewal. Compressive limbs therapy can solve blood stagnation problem in damaged sanguine vessels or in body zones not correctly bedewed.
  • Page 6: Machine Body

    Machine body (1) : ON/OFF button (2) : LCD graphic display (3) : Programs menu buttons (4) : Air discharge output Graphic display detail (1) MENU’ : menu selector (Mode, Pressure time, Interval, Time, Pressure). (2) MOVE : programs menu selector (Mode, Pressure time, Interval, Time, Pressure).
  • Page 7: Accessories

    (12) PRESSURE TIME : air flow speed (5,7,9,11,13,15,17,19,21 sec). (13) LEG PICTURE: shows the working compression chamber. Accessories EXTENSIONS FOR LEGGINGS LEGGINGS (10) 1 DERIVATION CONNECTION TUBES (11) ARMBAND (12) ABDOMINAL BAND PRESSURE PLANTARS 2 DERIVATIONS CONNECTION TUBES FOR LEGGINGS (13) SPECIAL SPLITTER FOR SIMULTANEOUS THERAPY ON BOTH LEGS AND ABDOMINAL BAND...
  • Page 8: Accessories Size

    Accessories size Legging: • Length around 76 cm (from upper side to heel) • Thigh circumference around 65 • Ankle circumference around 38 cm Armband: • Max. length around 86 cm • Biceps circumference around 50 cm • Wrist circumference around 36 cm Abdominal band: •...
  • Page 9: Configurations

    Configurations Power Q1000 Premium can be supplied in 5 different versions: POWER Q1000 PREMIUM TOT – compressive limb therapy system comprising machine body, double legging (6), 2 derivations connection tubes (9), 2 pressure plantars (8), armband (11), abdominal band (12), 1 derivation connection tubes (10), special connector for simultaneous therapy on both legs and abdominal band (13).
  • Page 10: Specifications

    Specifications POWER Q1000 Premium has the following specifications: • Class IIa equipment (Directive 93/42/EEC, annexed IX, rule 9); • Class II, applied part type BF (Classif. CEI EN 60601-1); • CE0476 certificate; • Equipment not protected against liquids penetration; • Equipment and accessories not subjected to sterilization;...
  • Page 11: Working Instructions

    Working instructions Accessories use a) Leggings use Wear the leggings (or single legging) and close the zip up to the end, then close the retaining Velcro straps; in case of wide circumferences legs, connect the extensions available as accessories; VELCRO CONNECTION PLUGS PRESSURE PLANTARS...
  • Page 12 b) Abdominal band use CONNECTION PLUGS Wear the band and connect the tubes to the band plugs, paying attention to connect the longer tube to the higher position connector on abdominal band; ii) After connecting the tubes to the band, connect the tubes to the air discharge output (5).
  • Page 13 v) Connect 4 tubes to the 4 plugs positioned on each legging, paying attention to connect the longer tube to the higher position connector (darker color) of legging (thigh); vi) After connecting the tubes to the relatives leggings, connect the tube to the splitter connected to the air discharge output (13);...
  • Page 14 Working instructions 1. Connect cable to the domestic plug 220-240 VAC, then turn ON (1) the ON/OFF switch (1); 2. Select the parameters by pressing on MENU’ button. 3. Press on MOVE button to scroll the menu (MODE, PRESSURE TIME, INTERVAL, TIME (min), PRESSURE (mmHg)).
  • Page 15 These two cycles are repeated in sequence till the end of duration of the treatment. 5. PRESSURE TIME: Select air flow speed by pressing SET buttons. You can choose 9 speed levels : 5,7,9,11,13,15,17,19,21 seconds. Default speed: 7 seconds. 6. INTERVAL: Select interval time by pressing SET buttons.
  • Page 16 Troubleshooting Problem Solution • Power Q1000 Check the connection to the domestic Premium doesn’t plug • switch on Check the ON/OFF button • Check the power supply status (no sign of damages) • Check the therapy time • Power Q1000 Check if there are any damages and/or Premium emits a holes in the tubes and connectors...
  • Page 17 • doesn’t go into the Check if the tubes are pressed or bent • chambers Check if the compression chambers swell up in a progressive way • Air goes into the Check if there are any holes or compression damages in the compression chambers. chambers and/or If there are not any air leakages, switch an air leakage is...
  • Page 18: Warnings

    Warnings The following warnings guarantee user safety and prevention against damages and/or lesions. Please read it carefully before using Power Q1000 Premium. Warning Caution In case of not following the instructions In case of not following the instructions the the user may suffer from serious user may suffer from serious injuries or injuries device damages...
  • Page 19 Do not use the device if you feel pain or Do not exceed 20 minutes in the first treatments. We suggest to start with bad feelings treatments of 5/10 minutes. Use only in consenting adults. Attention do not spill liquids or any substances on the device.
  • Page 20 Caution Use the device only for expected Do not expose the purposes. device to the sun do not storage it next to heat sources. Do not place any objects on the device or If you not use the device for a long time or on its parts (connector tubes, applicators, if you use the device in cold places, a etc.)
  • Page 21: Cleaning

    Cleaning Clean the device and its accessories using a soft cloth. Resistant stains can be removed using a sponge soaked in solution of water and mild soap. Wait for the complete drying before using the device and its accessories. Do not use chemical substances, solvents or cleaners to avoid device and accessories damage.
  • Page 22: Assistance

    this product, please use the designed areas for disposing electronic waste or contact the manufacturer. Assistance Every intervention on device must be performed by manufacturer. For any assistance intervention contact the national distributor or: I.A.C.E.R. S.r.l. Via S. Pertini, 24/a • 30030 Martellago (VE) -ITALY Tel.
  • Page 23 POWER Q1000 Premium is manufactured by: IACER Srl is the mandatary nominated by the manufacturer in the European Community with regard to POWER Q1000 Premium. POWER Q1000 Premium is an exclusive distribution of IACER SRL. POWER Q1000 Premium. All rights reserved. logos is owned by I.A.C.E.R.