System Led Indications - ParaZero SafeAir M-200 Pro Installation Manual

For systems equipped with electronic terminateair
Table of Contents

Advertisement

System LED indications

Stage
LED
Alternating
Purple/Teal
Solid Orange
Solid Red
Solid Green
Solid Yellow
Flickering
Red x1
Init
(*) Flickering
Yellow x1
Flickering
Yellow x2
Flickering
Yellow x3
Flickering Red x3
Solid blue (Idle)
After init
Solid Green
(Armed)
SafeAir™ M-200 Pro Installation Guide
Buzzer
Indication
NA
System didn't sync
with app for a long
time
NA
System battery is not
fully charged
NA
System battery is low
NA
System battery is fully
charged
NA
System is initializing
NA
Pyro error
NA
RC channel is
disconnected or in
active state
NA
System is not level
NA
System storage error
Repeating 3
IMU error
beep
pattern
Init finish:
System is ready to be
Single beep
armed. Will not trigger
the parachute.
System
disarm: two
beeps
Single beep
System is armed, will
deploy the parachute
if necessary
18
Required action
Connect system to Parazero
Desktop App to sync logs and
check for updates
Charging the system is
recommended but not
mandatory
Charging the system is mandatory
for operational use
None
None
1. Make sure that the parachute
cable is inserted
2. Try using the pyro dummy
3. Make sure that a pyro is
installed
4. Contact Parazero support
1. Check RC is on
2. Check that RC button is not
pressed
3. Check RC is paired to device
Check system is positioned on a
leveled surface
Format storage with ParaZero
Desktop App
1. Restart system
2. Contact Parazero support
None
None
www.parazero.com
7

Advertisement

Table of Contents
loading

Table of Contents