Flight Preparations - ParaZero SafeAir M-200 Pro Installation Manual

For systems equipped with electronic terminateair
Table of Contents

Advertisement

5.4 Flight Preparations

1
The SAP should be charged using the provided USB-C cable for at least 3 hours before
the first flight. The SAP is automatically charged during flight. If the system is not used often,
it should be charged before flight for 3 hours.
Charge the SAP when the safety pin is all the way in.
2
(Optional) Charge the RC using the provided USB cable for at least one hour before first
use. Charging should be made while the RC is turned off.
Caution
3
Using the desktop application allows for firmware update; automatic download of flight
logs and system configuration. Disconnect the FTS cable and the parachute cable from
the SAP, Take out the safety pin all way and connect the SAP to your computer using the
provided USB-C cable. The desktop application installation and use instructions may be
found here. Use the pyro-dummy connected instead of the parachute cable for the SAP
to complete initialization.
Warning
SafeAir™ M-200 Pro Installation Guide
When the RC is turned off or there is no link between the RC and the receiver, manual
triggering is not available
Please disconnect FTS and Parachute cables from the SmartAir to prevent activation during
firmware update process
12
www.parazero.com

Advertisement

Table of Contents
loading

Table of Contents