CAUTION: TK 2000 Speedy Clip System components should not
be reused. Failure to follow these instructions and/or the use of
TK 2000 Speedy Clip System hose with fittings supplied by other
manufactures could result in sudden or unintended escape of
refrigerant gases. Personal injury and/or violations of EPA
regulations may occur as a consequence.
NOTE: Thermo King recommends adherence to all guidelines, including
EPA guidelines concerning the service of refrigerant systems.
Improperly Installed Clip
Fabricating Refrigeration Hoses
Properly Installed Clip
Minimum Bend Radii
All hoses must be routed as to maintain the
minimum bend radii given in the table below.
Hose
Size
#6
#8
#10
#12
#16
Minimum
Bend
Radius
2.00 in.
2.50 in.
3.00 in.
4.00 in.
7.00 in.
35