Sign In
Upload
Manuals
Brands
Trane Manuals
Control Panel
VariTrac VAV-SVN03A-EN
Trane VariTrac VAV-SVN03A-EN Manuals
Manuals and User Guides for Trane VariTrac VAV-SVN03A-EN. We have
1
Trane VariTrac VAV-SVN03A-EN manual available for free PDF download: Installation Manual
Trane VariTrac VAV-SVN03A-EN Installation Manual (71 pages)
Central Control Panel
Brand:
Trane
| Category:
Control Panel
| Size: 5.32 MB
Table of Contents
Table of Contents
3
About this Manual
7
Contents
7
Compliance Information
7
Specifications
7
Varitrac Changeover Bypass System
7
Overview
7
Getting Started
7
Installing and Configuring the System
7
Troubleshooting
7
Delivered VAV System
7
Naming Conventions
8
Cautionary Statements
8
Related Literature
8
FCC Information
9
Varitrac and Delivered VAV Radio and Television Interference
9
Varitrac Changeover-Bypass System
11
Overview
11
Central Control Panel
11
Unit Control Module (UCM)
11
Varitrac Damper
11
Communicating Sensor/Bypass Damper Control
12
Varitrac Bypass Damper
12
Communicating Sensor/Bypass Control
12
Auxiliary Temperature Sensor
12
Zone Temperature Sensors
12
CO 2 Sensor
13
Occupancy Sensor
13
CO Sensor
13
Operator Display (Optional)
13
Service Model Number Description
13
Varitrac Changeover Bypass System Configuration
14
Specifications
15
Varitrac Central Control Panel
15
Operator Display
16
UCM Damper
16
Communicating Sensor/Bypass Control Assembly
17
Relay Board Binary Outputs
17
Wire Specifications
17
Getting Started
19
Unpack and Inspect the Components
19
Mount the Wiring Base
20
Mounting Requirements
20
Location
20
Operating Environment
20
Clearances
20
Secure Termination Module Wall
21
Secure Termination Module to Conduit Box
22
Install Varitrac CCP Relay Board
22
Wire AC Power
23
CCP Field Wiring
23
AC Power Wiring
24
AC Power Checkout
24
Binary Input Wiring
24
Priority Shutdown Input Wiring
24
Occupied/Unoccupied Input Wiring
25
Output Wiring
25
Install the Bypass Dampers and Communicating Sensor/Bypass Control Assembly
26
Install Bypass Dampers
26
Bypass Damper Wiring
27
Mount the Communicating Sensor/Bypass Control
27
Connect the Communicating Sensor/Bypass Control Wiring
28
Install the Varitrac Dampers
29
Connect UCM Wiring
30
Set the UCM DIP Switches
31
Slaved Dampers
32
Install the Zone Temperature Sensors
34
Location
34
Mounting Standard and Digital Zone Temperature Sensors
35
Wall Mount
35
Junction Box Mount
35
Zone Temperature Sensor Wiring
36
Communication Link Wiring
38
Mount Main Module
42
Install Operator Display (Optional)
43
Connecting Modem Devices
44
Connecting PC with Varitrac Software to CCP
45
Installation Checklist
47
Shipment
47
Unit Location
47
AC Power Wiring
47
Communicating Sensor/Bypass Assembly
47
Input Wiring
47
Output Wiring
47
Varitrac Dampers
48
Zone Temperature Sensors
48
UCM Wiring
48
Communication Link Wiring
48
System Start-Up and Checkout
49
Pre-Power-Up Checkout
49
Central Control Panel
49
Ucm
49
Occupied Mode
50
Unoccupied Mode
50
Powering down the System
50
UCM Leds
50
Green LED
51
Yellow LED
51
Tests and Troubleshooting
53
Displayed Failures
53
Static Sensor Calibration Failure
53
Discharge Air Temperature Sensor Failure
53
Communication Failure
53
Zone Sensor Failure
54
Zone Setpoint Failure
54
Auxiliary Sensor Failure
54
Static Pressure Sensor Troubleshooting
54
Zone, Auxiliary and System Temperature Sensor Checkout
54
UCM Local Heat Checkout
56
Central Control Panel Input/Output Test
56
Binary Input Tests
56
Communicating Sensor/Bypass Control Test
56
Supply Air Temperature Input Test
56
Static Pressure Sensor Input Test
57
Binary Output Test
57
System Troubleshooting
57
Delivered VAV System
59
Overview
59
What Is Delivered VAV
59
What Delivered VAV Is Not
59
Central Control Panel
61
Unit Control Module (UCM)
61
Varitrane VAV Terminal Units
61
Varitrane VAV Terminal Unit Types
61
Single Duct
61
Parallel Fan-Powered
61
Series Fan-Powered
61
Auxiliary Temperature Sensor
62
Zone Temperature Sensors
62
CO 2 Sensor
62
CO Sensor
62
Occupancy Sensor
62
Operator Display
62
Getting Started
63
Installing the Central Control Panel
63
Install Varitrane VAV Terminal Units
63
Connect UCM Wiring
63
Set UCM DIP Switches
63
Installing Zone Temperature Sensors
63
Communications Link Wiring
63
Installation Checklist
69
Shipment
69
Unit Location
69
AC Power Wiring
69
Input Wiring
69
Varitrane Terminal Units
69
Zone Temperature Sensors
69
UCM Wiring
69
Communication Link Wiring
70
Completing Central Control Panel Assembly
70
Mount Main Module
70
Install Operator Display
70
Connecting Modem Devices
70
Advertisement
Advertisement
Related Products
Trane VariTrac VAV-SVU01A-EN
Trane VariTrac X13650940010
Trane VariTrac X13650942010
Trane VariTrane VAV-SVX02B-EN
Trane VAV VV550 LonTalk
Trane VariTrane VCCF
Trane VariTrane VCWF
Trane VariTrane VPEF
Trane VariTrane VSCF
Trane VariTrane LPCF
Trane Categories
Air Conditioner
Heat Pump
Chiller
Air Handlers
Furnace
More Trane Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL