System Charging - Trane Thermo King V-520 RT SPECTRUM 50 Installation Manual

Multi-temperature systems truck edition
Table of Contents

Advertisement

Procedures
NOTE: Ensure proper leak check and evacuation procedure was
performed.
1. If gauge set is still connected from the evacuation, ensure gauge set is
free of non-condensables and connect the refrigerant bottle to the gauge
manifold.
2. If gauge set is not connected to unit, connect the refrigerant bottle and
purge the gauge fitting lines and connect the gauge manifold set to the
suction and discharge service ports on the engine driven compressor.
3. Place refrigerant bottle on scale and zero scale.
4. Keep the low pressure side valve of the gauge manifold closed. Open
the high pressure side valve.
5. Add the proper amount of refrigerant for your model.
REFRIGERANT
Model 50
NOTE: The refrigerant charge must be made in liquid phase for R-404A.
6. Close the refrigerant bottle valve and the high side valve of the gauge
manifold.
7. Start the vehicle's engine, run at approximately 1000 rpm and turn the
unit ON.
8. Set the unit thermostat at 0C/32F (see operating manual).

System Charging

AMOUNT OF
5.00 lbs.
9. Run the unit until it reaches a temperature close to that indicated, and a
high circuit pressure of 19 bar (275 psig for R-404A). Partially block
off the air intake to the condenser if necessary.
10. Open the low side valve of the gauge manifold and the refrigerant
bottle valve, and add refrigerant slowly until no bubbles can be seen
through the liquid sight glass.
11. Close the refrigerant bottle and gauge manifold valves.
12. Leave the unit running for 15 minutes.
13. Check that there are no bubbles in the sight glass. If bubbles are seen,
repeat steps 10 and 11.
14. Turn the unit OFF, stop the vehicle's engine and remove the gauge
manifold.
NOTE: The above conditions MUST be established each time the
refrigerant level is checked or if refrigerant needs to be added for any
reason.
60