Kenwood NX-3220 K Service Manual page 82

Vhf digital transceiver, uhf digital transceiver
Table of Contents

Advertisement

Item
Condition
Panel tuning
mode
4. Squelch
1) Adj item:
Open
[Aw SQL]
Adjust:[****]
[Analog
2) Adj item:
Wide 5k]
[L1]→
[L3]→
[C2]→
[H1]→
[H3]
SSG output:
12dB SINAD
level -3dB
(MOD: 1kHz/
±3kHz)
[Analog
1) Adj item:
Wide 4k]
[As SQL]
Adjust:[****]
2) Adj item:
[L1]→
[L3]→
[C2]→
[H1]→
[H3]
SSG output:
12dB SINAD
level -3dB
(MOD: 1kHz/
±2.4kHz)
[Analog
1) Adj item:
Narrow]
[An SQL]
Adjust:[****]
2) Adj item:
[L1]→
[L3]→
[C2]→
[H1]→
[H3]
SSG output:
12dB SINAD
level -3dB
(MOD: 1kHz/
±1.5kHz)
1-82 (No.RA053<Rev.001>)
PC test mode
Test-
equipment
1) Adj item:
SSG
[Squelch Open
Distortion
(Analog Wide 5k)]
meter
2) Adj item:
Oscilloscope
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±3kHz)
1) Adj item:
SSG
[Squelch Open
Distortion
(Analog Wide 4k)]
meter
2) Adj item:
Oscilloscope
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±2.4kHz)
1) Adj item:
SSG
[Squelch Open
Distortion
(Analog Narrow)]
meter
2) Adj item:
Oscilloscope
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±1.5kHz)
Measurement
Unit Terminal Unit
Panel ANT
Panel
SP/MIC
connector
Panel ANT
Panel
SP/MIC
connector
Panel ANT
Panel
SP/MIC
connector
Adjustment
Parts
Method
[Panel tuning mode]
After input signal from
SSG, press [
]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
[Panel tuning mode]
After input signal from
SSG, press [
]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
[Panel tuning mode]
After input signal from
SSG, press [
]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
Specifica
tions
/Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents