Daewoo DWF-1095 E Series Manual page 26

Table of Contents

Advertisement

EEPROM UNIT
1. CIRCUIT DIAGRAM
2. EXPLANATION OF CIRCUIT
In contrast with mask ROM, EEPROM which enable WRITE/READ by program, memorize data even
during POWER is OFF.
• EEPROM PIN FUNCTION
PIN NAME
FUNCTION
Chip selector
CS
Chip is enabled when CS is at 'L' level.
Set CS to 'H' level before executing instruction.
Clock input
CLK
The DI data is latched at the rising edge of CLK.
The data is out from DO at the falling edge of CLK.
CLK is enable when CS is at 'L' level.
DI
Serial data input
The address, command and data input pin.
DO
Serial data output
The data output pin
Organization select
ORG
The 16-bit organization is selected when ORG is 'H' level.
The 8-bit organization is selected when ORG is 'L' level.
Status output
RDY/BUSY
'L' level is output during program or chip eraise operation.
'H' level is output when program or chip eraise operation is completed.
EEPROM stores the selected contents in MEMORY course and LOAD SENSING data.
If you press MEMORY button, MICOM read the contents in MEMORY course and L.E.D displays the
selected contents in MEMORY course.
3. CAUTION FOR A/S
1. When the selected contents of MEMORY course in EEPROM can not memorize, EEPROM is
defective.
49
HOW TO CHECK THE P.C.B. ASS'Y
COURSE 1
Keep pushing three button (WASH, RINSE, SPIN SELECTOR) together and turn on the power switch.
No.
TIME
DISPLAY
1
SEC
2
SEC
H.
WASH
FEED
RINS
RES
SPIN
DRY
HOT
COLD
3
SEC
M.
L.
S.
MIN.
TIME
HOUR
MIN. REM.
TIME
ES.
COURSE2
Keep course 1 and pushing button of RINSE and SPIN
•RINSE BUTTON
DISPLAY
H.
FUZ.
SPEE
SOAK
WASH
FEED
RINS
RES
SPIN
DRY
HOT
COLD
M.
MEM.
STRO
L.
SOAK.
NIGHT
S.
SUIT.
BLAN
HOUR
TIME
HOUR
MIN.
REM.
TIME
MIN.
ES.
SILK.
DRY
•SPIN BUTTON
TIME TO PUSH
DISPLAY
THE SPIN BUTTON
1st Time
2nd Time
FUZ
3rd Time
FUNCTION
State of first lighting.
Temperature which sensing thermistor.
LO : Thermistor open.
HI : Thermistor short.
FUZ.
SPEE
MEM.
STRO
All LED light 8 times and go back to first stage.
SOAK.
NIGHT
SUIT.
BLAN
SILK.
DRY
FUNCTION
drain` `off` `cold water` `off` `hot
water` `off` `pulsator
rotate(right)` `off` `bubble` `off` `pulsator
rotate(left)` `off pump `off` `fan` `off` `heater
` `off` `load check` `off` `door
check` `off` `all led light
FUNCTION
FUZ
drain` `spin` `cold water` `hot
water` `pulsator rotae(right) bubble `pulsator
FUZ
rotae(left)` pump` fan` `heater` `door
check(dc/do)` `off
Repeat drive without "off" in "d2"
function