• Part of the button scan
The system of the BUTTON SCAN is in wide use for the method of the DUTY output part in L.E.D DRIVE,
yet here, it is in use for the method of the segmental output.
• Though the period of the DUTY part is 1/9, the last 9th part does not generate the waveform and checks
the button input with getting out the segmental output at the same time.
• The RA1(473J, 47KΩ) is a 'PULL DOWN' resistance for preventing floating action.
• The D15 prevents the L.E.D from turning on unnecessarily with forming the closed loop like a threaden
line at the time of button push.
43
Duty Part
Waveform
No Generation
Segmental Waveform
for Button Input
Segment Part
OSCILLATION UNIT
1. CIRCUIT DIAGRAM
2. EXPLANATION OF CIRCUIT
• As the OSCILLATION UNIT is a basic part of the MICOM DRIVE. If the oscillation doesn't generate, we
able to consider that the MICOM is destroyed.
• The waveform between the part of 1
and the GND
• Specification of oscillator
TYPE OF OSCILLATOR
MAKER
12 MHZ
MURATA
CERAMIC RESONATOR
32.768KHZ
KYOCERA
CRYSTAL OSCILLATOR
• It is general use for the MICOM maker's recommendatory value of condenser which is fit for MICOM's
characteristics.
• The R82(10MΩ, 1/6W) is in use to get rid of the initial abnormal oscillatory phenomenon of the 32.768
KHz crystal oscillator.
Murata 3 Terminal
Ceramic Resonator
(CST 12.00MTW)
Kyocera 32.768 KHz
Crystal Oscillator
(KF-38G-13P0200)
The waveform between the part of 2
and the GND
CONDENSER
NAME OF OSCILLATOR
C1
CST 12.00 MTW
33 PF
KF-38G-13P0200
18PF
C2
33PF
18PF
44