Information in the "Energy cockpit"
Energy consumption correction factor
You can enter a correction factor to adjust the dis-
played (calculated) values for energy consumption/fuel
consumption to the actual values (as measured by the
meter in your home). The calculated value is multiplied
by the correction factor. However, due to seasonal cli-
mate conditions and other factors, discrepancies may
still arise.
Tap the following on-screen buttons:
1. If required,
for the home screen
2.
/
for the "Energy cockpit"
Central heating and DHW heating energy consumption distribution
Specify the ratio in which your total energy consump-
tion (100 %) is split into energy consumption for central
heating and energy consumption for DHW heating.
You can estimate the values or establish them through
repeated meter readings over the year.
The values set here are only used in the graphs for
energy consumption ("Fuel consumption").
Factory setting:
DHW heating: 65 %
Central heating: 35 %
Tap the following on-screen buttons:
1. If required,
for the home screen
Operating program information
Using the operating program, you set e.g. whether you
want rooms heated, or DHW heating only.
Operating programs for central heating, DHW, frost protection
Symbol
Operating program
Central heating and DHW heating
"Heating and DHW"
Only for systems without DHW cylinder:
"Heating"
(cont.)
3.
in conjunction with a gas boiler
or
in conjunction with an oil boiler
4.
for "Fuel consumption"
5.
"Input adjustment factor"
6.
/
for the required correction factor
7.
to confirm
2.
/
for the "Energy cockpit"
3.
in conjunction with a gas boiler
or
in conjunction with an oil boiler
4.
for "Fuel consumption"
5.
"Proportion DHW - heating"
6.
/
for the required value, either for "DHW" or
"Heating". The other value is adjusted automati-
cally so that the total of both values is 100 %.
7.
to confirm
Function
The rooms are heated in accordance with the
settings of the room temperature controller (see
chapter "Central heating").
DHW is heated in accordance with the settings
for the DHW temperature (see chapter "DHW
heating").
The rooms of the selected heating circuit are
heated in accordance with the room temperature
and time program specified: See chapter "Cen-
tral heating".
Control unit operation
13