GENERAL DESCRIPTION

The MegaPower II 2050 Switcher/Control System is an
integrated matrix switching and control system for CCTV
surveillance systems. It is capable of controlling up to 1024
video input sources such as cameras, and 128 video outputs
such as monitors and video tape recorders.
The 2050 system consists of a matrix switching bay, its power
supply module, a data receiver/buffer module, the required
video input modules (VIM), video output modules (VOM), and
appropriate rear panels. All 2050 systems are controlled with a
separate central processing unit (CPU) and keyboard.
2050 Switcher/Control Systems are supplied as completely
configured switching bays. Only the bay interconnections, the
CPU connections, the video input and output connections, and
any optional accessory connections need be made prior to
operation. The 2050 system, as delivered, is a complete
system with all inputs terminated in 75 ohms. Each bay is
packed in a separate shipping carton labeled with the 2050 bay
assembly number on the outside of the carton.
Matrix Switching Bay
The 2010R and 2020R switching bays include the physical
chassis, a back plane, a power supply module, and a data
receiver. Each bay has the capability of looping the DATA
LINE input and looping an external vertical synchronization
pulse to other bays. Each bay also accommodates a
combination of video input modules and video output modules,
up to a total of 16 modules.
Power:
50 watts (full system)
Size:
10-1/2" height. Full-width 19" rack mount
Weight: 60 lbs. (28 kg) (full system)
CPU (Central Processing Unit)
The CPU for the 2050 system is a separate rack-mounted unit
that includes its own power supply, system software, ten RS-
232 ports, a system diagnostic monitor output, and two DATA
LINE outputs. These DATA LINE outputs distribute high
speed data control signals to the 2050 matrix switching bays
and optional accessories.
1995C Central Processing Unit
Power: 20 watts
Size:
3.5" height. Full-width 19" rack mount
Weight: 10 lbs. (4.5 kg)
1996A Central Processing Unit
Power: 4 watts
Size:
1.75" height. Full-width 19" rack mount
Weight: 10 lbs. (4.5 kg)
OPTIONAL EQUIPMENT
The following separate units may be connected to the 2050
system for added capabilities. For specific information, refer
to the respective data sheets.
2091 Control Code Generator/Distributor
The 2091 provides 64 control-code outputs for control of 1640
and 1680 Series Receivers actuating pan/tilt; lens zoom, focus,
and iris; and auxiliaries at suitably-equipped camera sites.
2031 Switcher/Follower,
2032 Alarm Responder,
2033 Auxiliary Follower
The 2030 Series Followers switch external circuits when
designated cameras are called to designated monitors (2031),
when designated monitors are in alarm conditions (2032), or
when designated auxiliaries are called up or designated
cameras are alarmed (2033).
2016LP Looping Panel
The 2016LP and 2016LP-1 Looping Panels are used to
facilitate the looping of video signals for the 2050 system from
external inputs or to external devices such as time-lapse video
recorders, switchers, monitors, etc.
Other Switcher/Control System Accessories
• 1640 and 1680 Series Receivers
• 1670 and 2078 Series Keyboards
• 1680MG Manchester Generator
• 1683 Control Code/PSK Modem
• 1981 Port Expander
• 1983 Code Converter
• 2083 Code Translators
• 2096 Alarm Interface Unit
IF YOU ENCOUNTER ANY PROBLEMS
OPERATING THIS UNIT, OR NEED ASSISTANCE,
CALL OUR TECHNICAL SUPPORT CENTER AT:
within the United States: 1-800-442-2225
outside the United States: (914) 624-7640
This installation should be made by qualified service personnel
and should conform to all local codes. Safeguards must be
taken to avoid unintentional operation by employees and
maintenance personnel working about the premises, by falling
objects, by customers, by building vibration, and by similar
causes.