Setup; Data Buffer Module - American Dynamics AD2052 Installation And Operating Instructions Manual

Matrix switching bays
Hide thumbs Also See for AD2052:
Table of Contents

Advertisement

SETUP

SETUP - Internal Jumper Switches
CAUTION - Due to the presence of non-insulated
components with hazardous voltages, the
following internal adjustments should be
performed by qualified service personnel only.
Data Buffer Module Switches
The 2010DB Data Buffer Module serves a dual purpose. First,
it sends video to the monitors and second, it filters incoming
information from the high speed LAN line.
Filtering is accomplished with two 8-position DIP switches, S2
and S3. Switch position 1 of switch S2 turns the filter "ON" or
"OFF." If S2 is set to"ON", all information passes and S3 does
not have to be set. If S2 is set to "OFF", only specified
information passes and S3 must be set. The S3 switch allows
only the necessary information to pass for that particular bay.
In the Condensed Bay configuration, or when a bay
contains 2024VOM monitor modules, the filter is set such
that all information passes. Therefore, position 1 of switch
S2 is set to ON.
For all other configurations the filter is set such that
information is filtered, thus position 1 of switch S2 is set to
OFF and S3 must be set accordingly. This applies to bays
which contain only 2016 VIM camera modules.
The Data Buffer Module also has a 2-position slide switch, S1.
S1 switches the card into either a normal mode or test mode.
S1 should be kept at the normal position.
Figure 25 shows the location of these switches on the 2010DB
PCB card.
1
8
S3
1
8
S2
S1
Figure 25 - Data Buffer Card Switches
Table 1 - S2 and S3 switch settings
1=On; 0=Off; X=Don't care
Filter
Pass all information (S2 ON)
Pass only specified information (S2 OFF)
Note: S2 must be set to pass all information (ON) in
bays which contain 2024VOM monitor modules.
Camera Monitor
1-256
1-16
257-512
1-16
513-768
1-16
769-1024
1-16
1-256
17-32
257-512
17-32
513-768
17-32
769-1024
17-32
1-256
33-48
257-512
33-48
513-768
33-48
769-1024
33-48
1-256
49-64
257-512
49-64
513-768
49-64
769-1024
49-64
12
Switch S2
1 2 3 4 5 6 7 8
1 0 X X X X X X
0 0 X X X X X X
Switch S3
1 2 3 4 5 6 7 8
X X 0 0
X 0
0 X
X X 1 0
X 0
0 X
X X 0 1
X 0
0 X
X X 1 1
X 0
0 X
X X 0 0
X 1
0 X
X X 1 0
X 1
0 X
X X 0 1
X 1
0 X
X X 1 1
X 1
0 X
X X 0 0
X 0
1 X
X X 1 0
X 0
1 X
X X 0 1
X 0
1 X
X X 1 1
X 0
1 X
X X 0 0
X 1
1 X
X X 1 0
X 1
1 X
X X 0 1
X 1
1 X
X X 1 1
X 1
1 X