Data Carrier Installation
When Combined With V600-H07
Gap between R/W Head and metal (x)
Effect of Misalignment
V600-D8KF04
32
When the V600-D8KR04 is flush-mounted in a metal casing, the transmission
range varies according to the width of the gap (x) between the metal and the DC,
as shown in the following graphs.
±
(Shaft slip:
0 mm)
R/W Head
DC
(over 100 mm)
The transmission range will be reduced if the R/W Head does not face the DC
directly when data is transmitted. Try to keep any misalignment below 10°, as
shown in the following diagram.
Read/Write Head
X mm
Flush-mounted in metal casing
(The transmission range varies according to the width of the gap (x).)
When Combined With V600-H11
Correct
DC
X mm
Flush-mounted
Metal
(Shaft slip:
R/W Head
(over 100 mm)
Gap between R/W Head and metal (x)
Incorrect
DC
θ
Read/Write Head
Surface-mounted
20 mm max.
Metal
Surface-mounted on metal
Section
4-2
±
0 mm)
DC
This angle should
not exceed 10°.