R/W Head Installation

4-1-2 Effect of Surrounding Metals

V600-H07 R/W Head
30 mm max.
Metal casing
V600-H11 R/W Head
23 mm max.
28
In addition to surface mounting, it is also possible to flush-mount the V600-H07
within a metal casing to protect it from being struck by other objects. To prevent
malfunctioning, allow at least 50 mm between the sides of the R/W Head and the
metal casing, and do not mount the R/W Head below the metal surface. If the
gap between sides of the R/W Head and the metal casing is less than 50 mm, the
read/write transmission range will be greatly diminished.
50 mm min.
Note
1. Do not bend the R/W Head's cable into a curve tighter than 11 mm in radius.
2. The read/write transmission range will be reduced significantly if the R/W
Head is installed closer than 50 mm to metal surfaces.
In addition to surface mounting, it is also possible to flush-mount the V600-H11
within a metal casing to protect it from being struck by other objects. To prevent
malfunctioning, allow at least 30 mm between the sides of the R/W Head and the
metal casing, and do not mount the R/W Head below the metal surface. If the
gap between sides of the R/W Head and the metal casing is less than 30 mm, the
read/write transmission range will be greatly diminished.
Metal casing
50 mm min.
Note
1. Do not bend the R/W Head's cable in a curve tighter than 11 mm in radius.
2. The read/write transmission range will be reduced significantly if the R/W
Head is installed closer than 30 mm to metal surfaces.
11 mm
radius min.
11 mm
radius min.
Section
(Unit: mm)
50 mm min.
50 mm min.
(Unit: mm)
30 mm min.
30 mm min.