Intellex IP
3 Example: If cameras 1–8 are in CIF mode and cameras 9-16 are in 4 CIF mode:
• 480/16 = 30
• For cameras 1–8: 30/1 = 30
• For cameras 9–16: 30/4 = 7.5
• Max. aggregate = (30 x 8) + (7.5 x 8) = 300 ips
Setting Up the Rate
From the Setup Options screen, click Rate. The Per Camera Rate Configuration dialog appears.
Configure the
recording frame
rate of IP system.
Adjust the sliders
to set frame rates
for minimum,
normal, and alarm.
Move individually
or in groups of 2 or
3.
Connecting to Multiple Networks
This example illustrates a scenario that uses both network interface connections.
A company's goal is to establish an IP video security network that is visible from select machines
on the corporate network, while minimizing how performance affects the network. They set up a
dedicated IP security network that connects:
• 5 IP cameras
• a 4-channel encoder connected to 4 analog cameras
• the gigabit NIC connected to a gigabit switch using CAT5 cable
This network is isolated from a corporate network; the live video from the cameras will not affect
the corporate network's performance.