5.5.2 4F poison resistant catalytic bead sensor
The applicable coefficients are:
Chemical
Gas
Formula
Acetone
C3H6O
Acetylene
C2H2
Ammoniac
NH3
Benzene
C6H6
n-Butane
C4H10
Ethane
C2H6
Ethanol
C2H6O
Ethylene
C2H4
n-Hexane
C6H14
Hydrogen
H2
Isopropanol
C3H8O
JP-4
JP-5
JP-8
Methane
CH4
Methanol
CH3OH
n-Pentane
C5H12
Propane
C3H8
Styrene
C8H8
Toluene
C7H8
Xylene
C8H10
: recommended gas for detector calibration
Table 4: Coefficients for the calibration of detectors equipped with a 4F poison resistant catalytic bead
Please note (Table 3 and 4):
• LEL values vary according to the source
• Coefficients are accurate to ± 15 %.
• For other gases/vapors consult our technical service.
NPO60GB
Revision F.2
Vapor
LEL %
LSE %
density
2,15
13,0
2,3
100
15,0
30,2
1,2
8,0
1,5
8,5
3,0
15,5
3,3
19,0
2,7
34,0
1,2
7,4
2,48
4,0
75,6
0,07
2,15
13,5
5,0
15,0
0,55
5,5
44,0
1,4
8,0
2,0
9,5
1,1
8,0
1,2
7,0
1,0
7,6
FIXED POINTGAS MONITOR
C5H1
CH4
2
Coef
Coef
2,1
2,24
1,03
0,9
1,91
0,7
0,6
0,79
0,36
2,7
2,45
1,13
2,0
2,16
0,99
1,0
1,47
0,78
1,6
1,37
0,63
1,0
1,41
0,65
2,85
1,14
2,1
1,84
0,85
3,28
1,51
3,33
1,53
3,48
1,6
1,0
1,1
1,27
0,58
2,5
2,17
1,0
1,6
1,9
0,87
3,6
2,13
0,98
3,1
2,26
1,04
3,7
2,8
1,29
OLCT 60
USER MANUAL
H2
Coef
1,1
1,0
33