Ensure the specificity of the numbering between GD10P and the OLCT 60D.
2.7.7
Detector grounding
Connect the enclosure ground points to earth according to the regulations with a 4mm² (11
AWG) wire.
The OLCT 60 features an internal ground point as well. The internal grounding shall be preferred
as the primary equipment ground.
2.7.8
Closing the cover
Before connecting the OLCT 60 to the controller, the cover shall be tightly closed. Firmly tighten
the locking screw as well (see Figure 16, page 13).
NPO60GB
Revision F.2
GD10P
1
(+24Vdc)
3
2 (0V)
2 (0V)
3
(mA)
1
4 (not used)
4 (not used)
5 (not used)
N/A
Figure 20: wiring the OLCT 60D/GD10P.
Figure 21: OLCT 60 grounding