Teledyne OLCT 60 User Manual page 21

Fixed pointgas monitor
Table of Contents

Advertisement

Ensure the specificity of the numbering between GD10P and the OLCT 60D.
2.7.7
Detector grounding
Connect the enclosure ground points to earth according to the regulations with a 4mm² (11
AWG) wire.
The OLCT 60 features an internal ground point as well. The internal grounding shall be preferred
as the primary equipment ground.
2.7.8
Closing the cover
Before connecting the OLCT 60 to the controller, the cover shall be tightly closed. Firmly tighten
the locking screw as well (see Figure 16, page 13).
NPO60GB
Revision F.2
GD10P
1
(+24Vdc)
3
2 (0V)
2 (0V)
3
(mA)
1
4 (not used)
4 (not used)
5 (not used)
N/A
Figure 20: wiring the OLCT 60D/GD10P.
Figure 21: OLCT 60 grounding
FIXED POINTGAS MONITOR
OLCT60
(+24Vdc)
(mA)
OLCT 60
USER MANUAL
028
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Olct 60dOlct 60idOldham simptronics olct 60

Table of Contents