Stroke Setting & Adjustment (Fig 3) - Stanley Avdel NeoBolt PB2500N Instruction And Service Manual

Battery power tool
Hide thumbs Also See for Avdel NeoBolt PB2500N:
Table of Contents

Advertisement

E N G L I S H
Note: DO NOT use spanners to mount Collet (A) onto Front Clutch (Q). Manual tightening of Collet (A) is enough to
lock onto Front Clutch (Q)
3.3 STROKE SETTING & ADJUSTMENT (FIG 3)
3.3.1 INITIAL STROKE SETTING
Determine Application pin stick out length in millimeters ("L" in fi gure below).
Remove battery pack from tool.
Remove Nose Housing (C) and Collet (A) to expose the Stroke Adjustment Pin (N).
Set the Stroke Adjustment Pin (N) to fl ush with Pulling Head Adapter (P).
Rotate the Stroke Adjustment Pin (N) clockwise (CW) according to the following:
Mount the Nose Housing (C) and Collet (A) and tighten the Nose Housing Nut (D).
Verify setting by installing NeoBolt® in Application Grip.
Length (L)
15mm
16mm
17mm
18mm
19mm
20mm
21mm
22mm
23mm
3.3.2 STROKE ADJUSTMENT (FIG 3 & 4)
Remove battery pack from tool.
Insert 2.0mm Hex Key (BB) into front of the tool through the hole in the Collet Stop (Z).
Adjust the tool stroke by rotating the Stroke Adjustment Pin (N) to achieve the desired NeoBolt®
installation. (Ref. Fig. 4)
Each rotation of the Stroke Adjustment Pin (N) changes tool stroke by 1mm (0.04")
To increase the stroke, rotate Stroke Adjustment Pin (N) counter-clockwise (CCW).
To Reduce the stroke, rotate Stroke Adjustment Pin (N) clockwise (CW).
Verify setting by installing NeoBolt® in Application Grip.
Repeat adjustment as needed.
18
Note: Stroke Adj.
pin set fl ush to
pulling head
Pin Adjustment (Number of Rotations)
10 full rotations (CW)
9 full rotations (CW)
8 full rotations (CW)
7 full rotations (CW)
6 full rotations (CW)
5 full rotations (CW)
4 full rotations (CW)
3 full rotations (CW)
2 full rotations (CW)

Advertisement

Table of Contents
loading

Table of Contents