Air Supply; Setting Instructions - Stanley ProSert XTN20 Instruction Manual

Hydro-pneumatic power tool
Hide thumbs Also See for ProSert XTN20:
Table of Contents

Advertisement

Available languages

Available languages

4.2 Air Supply

All tools are operated with compressed air at an minimum pressure of 5.0 bar.
Pressure regulators and automatic oiling/filtering systems to be used on the main air supply within
3 metres of the tool (see fig. 4).
Air supply hoses will have a minimum working effective pressure rating of 150% of the maximum pressure
produced in the system or 10 bar, whichever is the highest.
Air hoses must be oil resistant, have an abrasion resistant exterior and be armoured where operating
conditions may result in hoses being damaged.
All air hoses MUST have a minimum bore diameter of 6.4 millimetres.
Fig. 4
If above system is not available you can use the following alternative:
Before use or when first putting the tool into service, pour a few drops of clean, light lubricating oil into
the air inlet of the tool if no lubricator is fitted on air supply. If the tool is in continuous use, the air hose
should be disconnected from the main air supply and the tool lubricated as required.
Check for air leaks. If damaged, hoses and couplings must be replaced by new items.
If there is no filter on the pressure regulator, bleed the air line to clear it of accumulated dirt or water
before connecting air hose to the tool.

4.3 Setting Instructions

The stroke adjustment feature is mainly used for smaller insert sizes M3-M4.
If you are setting the tool for optimum stroke the Stroke Setter should be wound in to minimum stroke
(3mm) and the Pressure Regulator 19 be wound in to maximum setting.
If you are setting the tool for optimum pressure the Stroke Setter should be wound out to maximum
stroke (7mm) and the Pressure Regulator 19 be wound out to minimum setting.
When dealing with different grip thicknesses, it is always recommended that the tool is set for optimum
pressure rather than optimum stroke. Use the maximum grip condition to set optimum pressure.
3 METRES MAXIMUM
LUBRICATOR
1/4" GAS
CONNECTION
STOP COCK
(USED DURING MAINTENANCE
OF FILTER/REGULATOR OR
LUBRICATION UNITS)
PRESSURE REGULATOR AND
FILTER (DRAIN DAILY)
E N G L I S H
MAIN SUPPLY
13

Advertisement

Table of Contents
loading

Table of Contents