Positioning And Levelling The Appliance - Smeg FAB5 Use & Care Manual

Absorption minibar
Hide thumbs Also See for FAB5:
Table of Contents

Advertisement

The temperature conditions are listed in the table below:
Class
SN (Subnormal)
N (Normal)
ST (Subtropical)
T (Tropical)
• The absorption minibar must be placed at least 1 1/6" from electric or gas cookers and at least
11 5/6" from combustion or radiation heating systems.
• To allow proper cooling of the condenser, the absorption
minibar must not be placed too close to the wall. To prevent
this, the appliance comes complete with two plastic spacers
fitted at the top of the condenser. If the absorption minibar is
installed underneath a wall cupboard, the distance between
the two must be at least 5 cm.
• Position the absorption minibar so that the door can be
opened fully.
NOTE: Pay attention not to scratch or damage the floor when installing the appliance. If necessary,
when positioning slide the absorption minibar over pieces of wood or a mat to the point decided for
connection to the electrical mains.

3.3 Positioning and levelling the appliance

Place the absorption minibar on a firm, level surface. To
compensate for any unevenness in the floor, the absorption
minibar has four adjustable feet. This gives it added stability and
makes it easier to move around and position. Take great care
when moving the appliance not to damage the floor (for
example, when installing on a parquet floor).
8
Instructions for the Installer
Ambient temperature
from + 50° F to + 89° F
from + 61° F to + 89° F
from + 64° F to + 100° F
from + 64° F to + 109° F