TCS FBI6100-0400 Product Information page 4

Sip-gateway
Table of Contents

Advertisement

a/b/P
28|29|30
connection TCS:BUS
PASSIVE
Door release relay
21|22
(potential-free relay
contact – closing con-
tact)
Internal light switch
26|27
relay (potential-free
relay contact – closing
contact)
RJ45 socket
RUN/PROG push
button
RUN/PROG indication
RUN
PROG
(LED orange)
error indication at
ERR
TCS:BUS (LED red)
indication operation
voltage (LED green)
2
indication status voice
connection (LED or-
3
ange)
error indication SIP
(LED red)
4
status indication (LED
green)
status indication (LED
orange)
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de
www.tcsag.de
4
Only operation mode PASSIVE!
The supply voltage for the TCS:BUS is provided by an
additional power supply and control unit.
 This operation mode is selected if the SIP-Gateway
is integrated into e.g. a video system, a system with
several front-door stations, resp. if the system
which is to be supplied exceeds the power output of
the SIP-Gateways.
 Terminals are short-circuit protected.
 door release voltage via bridge terminal 20 to 21
 12 V, 50/60 Hz / 2 A (for door opener not less than
6 Ohm)
 door release time can be adjusted: 0 to 99 sec
 function can be adjusted via web interface
To control automatic light switching units,
the following extensions can be connected:
 automatic light switch unit (max. permitted contact
load capacity of 24 V DC / 1 A)
 staircase light control unit FNA1000 (or TZ1-SG)
(with 8 - 24 V AC)
 relay
 adjustable light switch time: 0 to 99 sec
 adjustable function via web interface
 connection for network (PC/Laptop) 10/100 Mbit
Only operation mode ACTIVE!
 Switching of the system mode:
operation mode – programming mode
 indication of the system mode:
is ON: operation mode
blinks: programming mode
 flashes: error in the connection to the TCS:BUS
(see page 8)
 flashes OFF: error in the network connection (see
page 8)
 is ON: operation voltage is present
 indication voice connection or connection estab-
lishment FBI610x to an external device
 is ON: start process (around 40 sec) or no connec-
tion to the SIP server (see page 8)
 blinks: if data is sent or received via LAN
 is ON: connection FBI610x to the network is estab-
lished
 is ON simultaneously green with status indication:
no connection to the network