Enter / Change Sip Settings - TCS FBI6100-0400 Product Information

Sip-gateway
Table of Contents

Advertisement

Enter / change SIP settings

 Register under Settings
VoIP.
 Select SIP settings in the
navigation bar.
 Enter here the necessary
data for your SIP server /
telephone system, which
you have determined during
the registration of the
FBI610x.
 Click Save.
Note for user name:
This field is used only for information and
does not have a special function. You
can enter e.g. the position of the fron-
door station.
The Reset button resets the content to the latest stored data state. It does not reload
!
the factory settings.
SIP
Displays, if the SIP-Gateway should register at the SIP-Server.
registration
If this option is not activated, only direct connections (peer to peer) can be realised. Thus,
the IP-address of the SIP-device, that is to be called, must be entered in the phonebook. A
connection via call numbers cannot be realised.
SIP server
Enter the IP-address or URL of the SIP providers / SIP server. The port number shows to
and SIP
which port the server belongs.
server port
SIP domain
The SIP domain is used to identify devices and to establish a connection. Thus, the num-
ber is used within the SIP protocol (e.g. 1234@sipgate.de). Without the domain no connec-
tion via call number can be realised. Instead of a name also the IP-address of the SIP
server can be entered.
SIP server as
Use the SIP server as proxy for outgoing calls. The SIP server has to support this function.
outbound
Thus, calling can be realised through a NAT firewall.
Proxy
DNS SRV
Use the DNS server entry to call a device within the SIP domain.
SIP
The user ID is the ID within a SIP domain. The ID is used to identify the SIP-Gateway. In
User ID
case of an incoming call the allocation is realised via the user ID. A caller transmits the call
request as "<Call number>@sipdomain.de" or as "<User-ID>@sipdomain.de".
SIP authenti-
User name to register at the SIP server.
fication ID
SIP authenti-
Password to register at the SIP server.
fication PIN
user name
The user name field is only for your information. It has no special function. Here you can
enter e.g. the position of the front-door station.
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de
www.tcsag.de
12
Subject to technical changes.
PI_FBI610x_uk 3 A
02/2014