Delay [s]
Select the delay period for the reaction of the video content analysis to trigger signals. The
alarm is only triggered after a set time interval in seconds has elapsed and then only if the
triggering condition still exists. If the original condition has been restored before this time
interval elapses, the alarm is not triggered. A delay period may be useful in avoiding false
alarms or frequent triggering. During the delay period, the Silent VCA configuration is always
enabled.
4
Notice!
If you have not yet created any fire detection profiles (see Fire detection and VCA profiles,
page 39 ), you must do so and go to Configuration > Alarm > Fire detection.
One example would be an environment with cleaning cycles. A key switch can be used as an
external trigger to switch between the different fire detection profiles.
Refer to
Bosch Sicherheitssysteme GmbH
Go to Interfaces, select Alarm Inputs and adapt the corresponding alarm input to your
needs.
Alarm input, page 24