Rs-232 2-4-6-8 Adapter Software; Dos-Compatible Software; Windows-Compatible Software - Extron electronics SW 4 AR MX HV User Manual

Hide thumbs Also See for SW 4 AR MX HV:
Table of Contents

Advertisement

SW ARxi xi xi xi xi and SW AR HVxi xi xi xi xi Operation, cont'd

RS-232 2-4-6-8 adapter software

DOS and Windows® -compatible software, for controlling
SW ARxi and SW AR HVxi switchers through the
RS-232 2-4-6-8 adapter, is provided on a 3.5-inch diskette.
Both versions enable the switcher input number to be
selected from the host computer/device.

DOS-compatible software

The DOS version of software for SW ARxi and SW AR HVxi
switcher input selection is a program called "Switch". The
program can be run on the PC computer from the 3.5 inch
diskette, but it may be more convenient to copy the
program to the PC's hard drive. To copy Switch from the
diskette to the hard disk, do the following:
1. Insert the 3.5 inch diskette into the PC's floppy disk
drive.
2. At the DOS prompt, type the following command:
Copy A:\SWITCH.COM C:\
DOS command format for "Switch"
The DOS command format for Switch is:
SWITCH sc [cp br db sb pt]
Parameters are described in the table below.
Code Description
Selections
sc
selection code
See table below
cp
comm port
Serial port number (1 - 4)
br
baud rate
300,600,1200,2400,4800,9600
db
data bits
7 or 8
sb
stop bits
0, 1, 2
pt
parity type
N=None, E=Even, O=Odd
Input
Number
1
2
3
4
5
6
Clear buffer
3-4
SW ARxi xi xi xi xi and SW AR HVxi xi xi xi xi • Operation
Defaults
1
4800
8
2
N
Selection
Code
254
253
251
247
239
223
255
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Following are two examples of Switch DOS commands.
Example 1
Switch 254
Switch 255
Explanation:
Line 1: Switch to input 1, using default parameters.
Line 2: Clear the RS-232 2-4-6-8 buffer, using default
parameters.
Example 2
Switch 223 2 4800 8 2 N
Switch 255 2 4800 8 2 N
Explanation:
Line 1: Switch to input 6, using comm port 2 at 4800 baud,
8 data bits, 2 stop bits, no parity
Line 2: Clear the RS-232 2-4-6-8 buffer, using comm port 2
at 4800 baud, 8 data bits, 2 stop bits, no parity
You can create batch files to simplify input
selection.

Windows-compatible software

The RS-232 2-4-6-8 Control Program is used with SW ARxi
and SW AR HVxi switchers and the RS-232 2-4-6-8 adapter.
It is compatible with Windows 3.1, 3.11, 95/98, and NT.
Installing the software
The program is contained on a single 3.5-inch diskette, and
it can run from the floppy drive. However, it is usually
more convenient to load and run the program from the
hard drive.
To install the software from the floppy disk onto the hard
drive, run SETUP.EXE from the floppy disk, and follow the
instructions that appear on the screen.
By default, the Windows installation places two icons
(RS-232 2-4-6-8 Control Pgm and 2-4-6-8 ctrlr notes) into a
group or folder named "Extron Electronics".
SW ARxi xi xi xi xi and SW AR HVxi xi xi xi xi • Operation
3-5

Advertisement

Table of Contents
loading