Wiring Standard System - Aiphone GH-1KD Installation And Operation Manual

Apartment intercom system
Hide thumbs Also See for GH-1KD:
Table of Contents

Advertisement

4
WIRING
Standard system
Capacity
5 Entrance stations
2 Security guard stations
48 Residential stations
Homerun wiring with GH-4Z
1Px2
1Px2
Doorbell
GH-1KD
GH-1MD
GH-1MD, unlike GH-1KD,
is only available to connect
on a trunk line
with GH-4Z used
Distribution
point
Light control
GH-RY
Timer
AC
Light
Door release
Entrance station
Trunk line #1
1Px2
1Px2
1Px2
1Px2
GH-4Z
1Px2
1Px2
GH-4Z
Doorbell
Doorbell
GH-1KD
Max. 4 apartment stations can be linked per Residence
(including max. 2 monitor stations)
1Px2
On the same trunk line, do not have two wiring methods mixed,
Station-to-station wiring and homerun wiring with GH-4Z
R1
R2
GH-BC
1Px2
PS24
#1
1Px2
1P
1P
GH-1AD
GH-1AD
GH-1KD
PS24
PS24
GH-VBC
1Px2
1P
Doorbell
- 16 -
1P(Audio)
1P(Video)
1P
Station-to-station wiring
Trunk line #2
Doorbell
GH-1KD
1Px2
Doorbell
GH-1KD
1Px2
1Px2
Trunk line
#3 - #6
1Px2
Entrance
#2 - #5
1P
GH-MK
#2
1P
PS24
GH-MK #1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gh series

Table of Contents