7-5

Door station setting

∗ There are three methods for setting door stations: individual
input, line copy-and-paste input, and column batch input.
1. Individual input
[1] Central exchange unit number (cannot be input)
• Displays the number of the central exchange unit to which the
corresponding door station is connected. This cell cannot be
input.
[2] Number (cannot be input)
• Displays the door station number displayed on the master
station's LED display. This cell cannot be input.
[3] Location Name
• This name is for display on the PC monitor only, and therefore is
optional. To input or edit location name, click the cell section
with the mouse. To finish editing, press Enter key or click
another cell.
[4] Door station type
• Select "None", "Video", or "Audio" as the setting for the
corresponding door station. If you click the cell section with the
mouse, a drop-down list is displayed. Click the appropriate
setting to select it. To finish editing, press Enter key or click
another cell.
[5] Call Level
• Select "Normal" or "Priority" as the call level for the
corresponding door station.
[6] Door Release Relay
• select "N.O." or "N.C." as the door release contact type for the
corresponding door station location.
[7] Scan Monitor
• Select "Enable" or "Disable" as the scan monitor target setting
for the corresponding door station.
[8] Master Station Call Tone
• Set "On" or "Off" for whether or not the master station rings
when there is a call from the corresponding door station. This
can be set whether or not there is a master station connected on
the corresponding channel.
[9] Door station list scroll bar
2. Line copy-and-paste input
When you right click the mouse in a valid cell, the door station
edit menu is displayed.
• "Restore Default(D)" returns all of the door station settings to
their default values.
• "Copy Line(C)" and "Paste Line(P)" allow you to copy and paste
door station settings one line at a time. However, a copied line
cannot be pasted into another AX setup tool application. In the
same way, data copied with another application cannot be pasted
into this one.
• "Master Station 1 to 8" allows the call tone setting to be selected
on all the master stations at once.
3. Column global selection
• When you right click the mouse on the top title section of a
column,the column input menu is displayed.
• To make a global setting in that column, click the appropriate
selection, and all stations will be changed to that setting.
4. Relationship with control unit settings
The door station settings can only be edited if the
corresponding exchange unit setting is already selected
(Exchange Unit/Master Station tab). Otherwise, door station
settings will be "grayed out".