2.7

Technical data

2.7.1

Technical data - servo drives

2.7.1.1

SINAMICS V90 200 V variant

General technical data
Parameter
Overload capability
Control system
Dynamic brake
Protective functions
Overvoltage criteria
Certification
Speed control mode
Speed control range
Analog speed command input
Torque limit
Position control mode
Max. input pulse frequency
Command pulse multiplying factor
In-position range setting
Error excessive
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
Description
300%
Servo control
Built-in
Earthing fault protection, output short-circuit protection
protection
, drive I
t protection, motor overtemperature protection, IGBT overtemper-
2)
2
ature protection
3)
Category III
Analog speed command 1:2000, internal speed command 1:5000
-10 V DC to +10 V DC/rated speed
Set through a parameter or the analog input command (0 V DC to +10 V DC/max.
torque)
1 M (differential input), 200 kpps (open collector input)
Electronic gear ratio (A/B)
A: 1 - 10000, B: 1 - 10000
1/50 <A/B < 200
0 to ±10000 pulse (command pulse unit)
±1/10 revolutions
General information
2.7 Technical data
, overvoltage/undervoltage
1)