Fuse/Type-E combination motor controller

A fuse/Type-E combination motor controller can be used to protect the system. Integral solid
state short circuit protection does not provide branch circuit protection. Branch circuit
protection must be provided in accordance with the National Electrical Code and any
additional local codes. Refer to the table below for the selection of fuses and Type-E motor
controllers:
200 V variant
SINAMICS V90
Recommended fuse
Frame
Rated
CE-compliant
size
power
(kW)
1-phase, 200 VAC to 240 VAC
FSA
0.1
3NA3 801 (6 A)
0.2
3NA3 801 (6 A)
FSB
0.4
3NA3 803 (10 A)
FSC
0.75
3NA3 805 (16 A)
3-phase, 200 VAC to 240 VAC
FSA
0.1
3NA3 801 (6 A)
0.2
3NA3 801 (6 A)
FSB
0.4
3NA3 803 (10 A)
FSC
0.75
3NA3 805 (16 A)
FSD
1.0
3NA3 805 (16 A)
1.5
3NA3 810 (25 A)
2.0
3NA3 810 (25 A)
The above types for Type-E combination motor controllers are listed in compliance with both CE and UL/cUL standards.
1)
400 V variant
SINAMICS V90
Recommended fuse type
Frame
Rated
CE-compliant
size
power
(kW)
3-phase, 380 VAC to 480 VAC
FSAA
0.4
3NA3 801 (6 A)
FSA
0.75
3NA3 801 (6 A)
1.0
3NA3 803 (10 A)
FSB
1.5
3NA3 803 (10 A)
2.0
3NA3 805 (16 A)
FSC
3.5
3NA3 807 (20 A)
5.0
3NA3 807 (20 A)
7.0
3NA3 810 (25 A)
The above types for Type-E combination motor controllers are listed in compliance with both CE and UL/cUL standards.
1)
50
Type-E combination motor controller
UL/cUL-compliant
Rated cur-
listed (JDDZ) fuse
rent (A)
6 A
2.8 to 4
6 A
2.8 to 4
10 A
5.5 to 8
20 A
9 to 12.5
6 A
2.8 to 4
6 A
2.8 to 4
10 A
2.8 to 4
20 A
5.5 to 8
20 A
7 to 10
25 A
10 to 16
25 A
10 to 16
Type-E combination motor controller
UL/cUL-compliant
Rated cur-
listed (JDDZ) fuse
rent (A)
10 A
2.2 to 3.2
10 A
2.8 to 4
10 A
3.5 to 5
15 A
5.5 to 8
15 A
11 to 16
25 A
14 to 20
25 A
14 to 20
25 A
20 to 25
Rated volt-
Rated
age (VAC)
power
(hp)
230/240
1/3
230/240
1/3
230/240
1
230/240
2
230/240
3/4
230/240
3/4
230/240
3/4
230/240
2
230/240
3
230/240
5
230/240
5
Rated volt-
Rated
age (VAC)
power
(hp)
380/480
0.5
380/480
1
380/480
1.34
380/480
2
380/480
2.68
380/480
4.7
380/480
6.7
380/480
9.4
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
1)
Article num-
ber
3RV 2011-
1EA10
1EA10
1HA10
1KA10
1EA10
1EA10
1EA10
1HA10
1JA10
4AA10
4AA10
1)
Article num-
ber
3RV 2021-
1DA10
1EA10
1FA10
1HA10
4AA10
4BA10
4BA10
4DA10

Advertisement