2.2.5.1 Phase unbalance protection
Choose the pin 1 to enable or disable the phase unbalance protection. When the function enabled, the
protection will limit the phase unbalance to 15A.
Configuration
2.2.5.2 Authorization mode
Choose the pin 2 to configure the authorization mode for bluetooth availability.
Configuration
*Bluetooth connection is reserved for commissioning purpose.
2.2.5.3 Grounding system
Choose the pin 3 to configure the grounding system for TT/TN or IT system.
Note:
1.
When installed in a TN systems, the supplying circuit shall not include a PEN conductor(combined
protective and neutral) .
2.
If the power grid belongs to TN-C-S system, the charger needs to be grounded separately to TT system.
A PME earthing facility shall not be used as the means for the protective conductor contact of a charging
point located outdoors.