IBM 3454-FCE Customer Install Manual

Cloud pak for data system
Table of Contents

Advertisement

IBM Cloud Pak for Data System
Customer Install Guide
Power Distribution Unit (PDU)
3454-FCE, FCG
Version 1.3
Note
Before using this information and the product it supports, read the information in
"Safety notices" on page 7, "Notices" on page 68, the IBM Systems Safety Notices
manual, G229-9054, and the IBM Environmental Notices and User Guide, 03FP290.
© Copyright IBM Corporation 2020.
Customer Install Guide, PDU
1

Advertisement

Table of Contents
loading

Summary of Contents for IBM 3454-FCE

  • Page 1 Note Before using this information and the product it supports, read the information in “Safety notices” on page 7, “Notices” on page 68, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, 03FP290. © Copyright IBM Corporation 2020.
  • Page 2 This edition applies to IBM Cloud Pak for Data System Components. February, June 2020 © Copyright IBM Corporation 2020. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. © Copyright IBM Corporation 2020.
  • Page 3: Table Of Contents

    Wye (3454-FCE) ......................22 Power Cords: Cloud Pak for Data System PDU, 3-Phase Delta, 200-208 V AC (3454- FCG) ..........................24 Modification of IBM-provided power cords ..............25 SRM excerpts ......................26 Definition of an alteration ................... 26 Rack Requirements ....................... 27 Rack Space ........................
  • Page 4 Changing the date and time ..................56 Changing event alerts ..................... 57 Changing the network information ................58 Changing the network configuration ............... 58 History and event log summaries ................59 © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 5 Password reset ......................61 Reset to factory defaults .................... 62 Electronic Emissions Notices ..................63 Regulatory and Compliance ..................67 Notices .......................... 68 Copyright License:......................71 Trademarks ........................72 Readers’ Comments ...................... 73 © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 6: Safety

    Safety © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 7: Safety Notices

    U.S. English source. Before using a U.S. English publication to install, operate, or service this product, you must first become familiar with the related safety information © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 8: German Safety Information

    Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard:  If IBM supplied the power cord(s), connect power to this unit only with the IBM provided power cord.  Do not use the IBM provided power cord for any other product.
  • Page 9 4. For AC power, attach the power cords to the outlets. 5.Turn on the devices. Sharp edges, corners and joints may be present in and around the system. Use care when handling equipment to avoid cuts, scrapes and pinching. (D005) © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 10: Danger And Caution Warnings

    It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock. (R001 part 2 of 2): CAUTION: © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 11 – Ensure that the heaviest devices are installed in the bottom of the rack cabinet. – Ensure that there are little-to-no empty U-levels between devices installed in the rack cabinet below the level, unless the received configuration specifically allowed it. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 12 (L001) DANGER: Hazardous voltage, current or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label. (L001) (L002) © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 13: Multiple Line Cords

    Do not place objects on top of rack-mounted devices. In addition, do not lean on rack- mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). (L002) Multiple Line cords (L003) © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 14: Weight Limits

    (English translation: If this product comes with power cords, such cords should be used exclusively for the applicable product, but not for other devices.) (English translation: After providing the main product, if additional power cord is required, the cord is handled for repair/maintenance/mending purpose.) © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 15: Publications

    PDU Description This document is used in conjunction with the IBM Rack and System Install Guide to provide guidance on the installation and setup of the Cloud Pak for Data System PDUs. Both documents can be found in the Safety and Regulatory CD that is shipped with your Cloud Pak for Data System components.
  • Page 16 See Table 4 and 447.5 mm 351 mm 42.5 mm 5.3 kg (1.67 in) Table 5 for line cords (17.62 in) (13.82 in) (1.67 in) (11.6 lb) and power types Figure 1: PDU Graphic © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 17: Planning

    Amperage and wattage of the loads can be found in the install documentation for the individual Cloud Pak for Data System building blocks or in the IBM Site Survey. Verify all information by cross checking with the rating labels located on the equipment in the rack.
  • Page 18 See figures 3 and 4 for typical redundant PDU install and connection to Cloud Pak building blocks. See figure 5 for physical PDU alignment in the rack. Figure 2: Circuit breaker loading information Figure 3: Example Power Cord Connection (3-phase, worst case) © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 19 Figure 4: Dual PDUs for redundant power Figure 5: Align PDUs as shown to differentiate between left and right redundant power. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 20: Plan For Power Outages

    Give the electrician a copy of your Power Information Table. IBM installers can also share reference wiring diagrams to clarify your power sizing needs. Note that IBM installers will do the in-rack power and signal cabling once the components and PDUs are racked.
  • Page 21: Operating Environment

    [3] Short term temperature only for servers with SSDs [4] Unit must acclimate to data center environment before unboxing to prevent condensation. [5] PDUs do not have fresh air cooling and can function in 60C (140F) environments © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 22: Power Cords: Cloud Pak For Data System Pdu 200-240 V Ac, 1-Phase & 400 V Ac Wye (3454-Fce)

    PDU comes with a geographically defined default line cord for standard data center receptacles worldwide. These default cords accommodate 30/32A single phase and are noted in the first column of Table 4 below. Table 4. 3454-FCE: Single phase and 3-phase wye power cords Description Female...
  • Page 23 32 A Australia 7,040 watts shipped and New with 3454- Single Zealand FCE PDU phase Mating for listed connector countries) 4.3 m (14 ft) type 56P332 Clipsal, P+N+G © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 24: Power Cords: Cloud Pak For Data System Pdu, 3-Phase Delta, 200-208 Vac (3454-Fcg)

    Taiwan type countries) 460C9W 4.3 m (14 ft) IEC 60309, 3P+G Power cord, Plug type Wall United 8,160 watts 02WN660 PDU to wall 430P9W receptacle States, derated ---------------- type Canada, © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 25: Modification Of Ibm-Provided Power Cords

    IBM encourages the use of an IBM released power cord because of the specifications that must be met for both the design and manufacture of our IBM power cords. The specifications, the components used in the design, and the manufacturing process is an external safety agency approved process that is audited by safety agencies on a periodic and ongoing basis to ensure quality and compliance with design requirements.
  • Page 26: Srm Excerpts

    SRM excerpts A cable group associated with a purchased IBM machine, and bearing an IBM label, is the property of the IBM machine owner. All other IBM furnished cable groups (except those for which specific purchase invoices have been paid) are the property of IBM.
  • Page 27: Rack Requirements

    Figure 6: Top down view of installed PDU with 4-point horizontal mounting Location in the Rack The base IBM Cloud Pak for Data System consists of four main components (1G switch, 25G switch, two compute chassis) that are designed to be integrated in the same rack with PDUs.
  • Page 28 Other configurations can be used if IBM Safety Notices translations Pub # G229- 9054 rules are followed, and the lengths of the supplied cables are not exceeded. PDUs mount on the top as shown. 4U Blank Panel 2U Blank Panel...
  • Page 29 Expansion chassis and switches can be racked in any order, but the preferred locations are shown in Figure 8. Expansion PDUs should be installed above the base PDUs. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 30 1U Blank Panel Labeled “2” Chassis 2 1U Blank Panel Chassis 1 Labeled “1” 1U Blank Panel Figure 8: Front view, Cloud Pak system with optional expansion chassis, switches and PDUs © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 31: Package Contents

    Package Contents: If anything is damaged or missing, contact your IBM representative. Contents: 3454-FCE, 3454-FCG PDU Kit PDU side rail Kit Safety Notices / Installation Instruction CD Power Distribution Unit (PDU) 1U, Front filler panel M5x16 Screw Communication cable Clip nuts, M5...
  • Page 32: Before You Begin

    Attach the adjustable mounting rails to each side of the PDU chassis by using the six screws that are included with the mounting kit. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 33 Use two M6 screws (A) if cage nuts are used or M5 screws if nut clips are used per bracket to attach the brackets to the nut clips or cage nuts on the rack flanges. Use screws that were provided with the rack mounting kit. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 34 9.g. Use two M6 screws (A) if cage nuts are used or M5 screws if nut clips are used per bracket to attach the brackets to the nut clips or cage nuts on the rear rack flanges. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 35 Alternate Method: The fillers that are shipped with your Cloud Pak rack can be reused in place of the filler that is shipped with the PDU for a more consistent look. Figure 12. Attaching the brackets and filler panel to the rack © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 36 Then, turn the twist-lock (B) on the connector clockwise until it locks into place. Figure 13. Disengaging the circuit breakers and aligning the connector on the power cord with the PDU. (L001) © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 37 13. Connect the power cord to a properly wired and grounded dedicated power source. IBM Installers will connect the components in the rack to the power outlets on the PDU. IBM installers will route all internal signal cables before powering on the system.
  • Page 38: Installing The Pdu In The Side Of A Rack (Alternate Method)

    Make sure that you attach the brackets so that the power outlets face the rear of the rack. Figure 14. Aligning the vertical-mounting brackets to the front of the PDU. (PDU picture for reference only, receptacle style may vary) © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 39 Then, while you hold the PDU model in place, attach the brackets to the nut clips in the rack mounting flanges with four M5 screws (A) as shown in the following figure. Use screws that were provided with the rack mounting kit. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 40 Align the connector on the power cord (A) that was provided with the PDU model with the connector on the front of the unit (A), turning as necessary for key alignment. Then, turn the connector twist-lock (B) clockwise until it locks into place. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 41 Attention To prevent damage to a power device and other connected devices, always connect the power device to an authorized power source for that device. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 42 8. Connect the power cord to a properly wired and grounded dedicated power source, IBM Installers will connect the components in the rack to the power outlets on the PDU. IBM installers will route all internal signal cables before powering on the system.
  • Page 43: Cable The Pdu To A Console, Lan And Output Devices

    2. On the workstation or notebook computer that you are connecting to the PDU, install the device drivers for the DB-9-to-USB converter cable, by using the instructions that come with the converter cable. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 44: Connecting The Pdu To A Lan

    The following illustration shows how to connect a router or switch to an Intelligent Switched PDU. Figure 19. Connecting a router or switch to an Intelligent Switched PDU © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 45: Connecting Output Devices

    RS-232 (Serial port) and Ethernet (Ethernet port) connectors. Connect a device that you want to monitor to a power outlet on the PDU with the power cord that comes with the device. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 46: Configuring The Pdu Via Serial (Com) Port

    Data bits: 8 Parity: None Stop bits: 1 Flow control: None Programs such as PuTTY only need a subset of the port settings. See Figure 20. Figure 20 PuTTY Serial Session Settings © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 47: Log In

    The default login ID is: Admin, press Enter. The default password is 00000000, press Enter. See Figure 22 Figure 22 - IBM PDU Configuration Utility Main Screen The Admin level main menu is displayed. See Figure 23 © Copyright IBM Corporation 2020.
  • Page 48: Setting The Ip Address

    IP addresses are allowed in the network. Also make sure that no other clients are using that IP address. If it is not possible to use the © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 49: Receptacle Configuration

    To change a field, type the input on the computer keyboard and press Enter. To keep the default value, press Enter. If the PDU Name and PDU description are changed, the PDU Information menu will show them. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 50 Figure 26 - Set PDU Location and Outlet Information The instantaneous real-time voltage, amps, watts, and relay status (on or off) can be displayed. Press 2 and then Enter. See Figure 27. Figure 27 – Real-time readings © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 51 EPO emulation is initiated. Recover to ALL ON means that when the receptacles are restarted, all relays will be on regardless of their state before the EPO emulation. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 52 Figure 29 - EPO Setup © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 53: Configuring The Pdu Via The Web Utility Menu Options

    Note some local laws may require the user to enter a new password before allowing web access. If a password reset is necessary, be sure to record the password for later use. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 54: Changing The Basic Settings

    To change the superuser name and password, complete the following steps: 1. From the main status page, in the left navigation pane, click Network/Access. 2. Click on “Password” to change superusers’ password. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 55: Identifying The Pdu And Web/Snmp Card

    2. Click “Hardware/Firmware Info” to view the PDU and Web/SNMP card information. Figure 33 WEB/SNMP Card information Adding users You can add users who can access and control the PDU on the Multi-User Configuration page. (See Figure 34) © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 56: Changing The Date And Time

    2. Click Date Time to view and modify the system date and time. You can set the date and time manually, synchronize it with the computer time, or synchronize it with an NTP server. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 57: Changing Event Alerts

    3. Click On Network/SMTP to create a list of up to four users that you want to alert. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 58: Changing The Network Information

    1. From the main status page, in the left navigation pane, click Network/TCP/IP 2. Click “Info” to set the PDU IP address, gateway address, subnet mask, and Domain Name System (DNS) address. 3. Click “Configuration” to configure TCP/IP settings. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 59: History And Event Log Summaries

    You can view the complete history of the PDU inputs and outputs on the Data Log window. To view the history of the PDU, complete the following steps: (See Figure 38) 1. From the main status page, in the left navigation pane, click History/Data Log . © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 60: Viewing The Event Log

    To view the complete record of the PDU events, complete the following steps (See Figure 39) 1. From the main status page, in the left navigation pane, click History/Event Log . Figure 39 Event Log © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 61: Resetting The Pdu

    See the Starting the Web Interface section for factory password log in instructions. If nothing is pushed while the yellow light is blinking, the password will not be reset. Figure 40 - Reset button sequence for password reset © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 62: Reset To Factory Defaults

    The PDU will not reset if nothing is pushed during the 10 seconds that the yellow LED is blinking. Figure 42 - Reset button sequence for PDU reset to factory defaults. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 63: Electronic Emissions Notices

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 64 Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non- recommended modification of the product, including the fitting of non-IBM option cards. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
  • Page 65 이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기기로서 가정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다. People's Republic of China Notice 声明: 此为 A 级产品,在生活环境 中, 该产品可能会造成无线电干扰 。 在这种情况下,可能需要用户对 其 干扰采取切实可行的措施。 Russia Notice © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 66 ВНИМАНИЕ! Настоящее изделие относится к классу А. В жилых помещениях оно может создавать радиопомехи, для снижения которых нео Taiwan Notice 警告使用者 : 這是甲類的資訊產品,在 居住的環境中使用時,可 能會造成射頻干擾,在這 種情況下,使用者會被要 求採取某些適當的對策。 IBM Taiwan Contact Information: © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 67: Regulatory And Compliance

    Regulatory and Compliance © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 68: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 69 Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
  • Page 70 All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 71: Copyright License

    You may copy, modify, and distribute these sample programs in any form without payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written.
  • Page 72: Trademarks

    IBM, the IBM logo, ibm.com® and Netezza® are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. If these and other IBM trademarked terms are marked on their first occurrence in this information with a trademark symbol (® or ™), these symbols indicate U.S.
  • Page 73: Readers' Comments

    IBM business partner, or your authorized remarketer. When you send comments to IBM, you grant IBM a nonexclusive right to use or distribute your comments in any way it believes appropriate without incurring any obligation to you. IBM or any other organizations will only use the personal information that you supply to contact you about the issues that you state on this form.
  • Page 74 © Copyright IBM Corporation 2020. Customer Install Guide, PDU...
  • Page 75 Part Number: 03GJ008 Printed in Mexico © Copyright IBM Corporation 2020. Customer Install Guide, PDU...