Advertisement

Quick Links

IBM Distributed Power Interconnect
IBM
Rack Power Distribution Unit
Installation and Maintenance Guide

Advertisement

Table of Contents
loading

Summary of Contents for IBM Rack Power Distribution Unit

  • Page 1 IBM Distributed Power Interconnect Rack Power Distribution Unit Installation and Maintenance Guide...
  • Page 3 IBM Distributed Power Interconnect Rack Power Distribution Unit Installation and Maintenance Guide...
  • Page 4 “Warranty information,” on page 17 and the notices information in Appendix B, “Notices,” on page 29. First Edition (March 2003) © Copyright International Business Machines Corporation 2003. All rights reserved. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
  • Page 5: Table Of Contents

    Purchasing additional services........19 IBM Statement of Limited Warranty Z125-4753-06 8/2000 .
  • Page 6 IBM Distributed Power Interconnect Rack Power Distribution Unit:Installation and Maintenance Guide...
  • Page 7: Safety

    Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. © Copyright IBM Corp. 2003...
  • Page 8 All caution and danger statements in this documentation begin with a number. This number is used to cross reference an English caution or danger statement with translated versions of the caution or danger statement in the IBM NetBAY Rack Safety Information book.
  • Page 9 Statement 4: DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: • Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. • Connect all power cords to a properly wired and grounded electrical outlet.
  • Page 10 California de los Estados Unidos está considerado como un causante de cancer y de defectos congénitos, además de otros riesgos reproductivos. Lávese las manos después de usar el producto. viii IBM Distributed Power Interconnect Rack Power Distribution Unit:Installation and Maintenance Guide...
  • Page 11: Chapter 1. Introduction

    Front-end PDU, or an uninterruptible power supply. The latest version of this publication is available from the IBM Web site. Go to http://www.ibm.com/ and click Support & downloads. In the Technical Support keyword search field, type "DPI PDU"...
  • Page 12 You will need the following tools to install the Rack PDU in a rack cabinet: • One Phillips screwdriver • One 10 mm (11/32-in.) wrench • One cage-nut-insertion tool or flat-blade screwdriver (for installing cage nuts in some rack cabinets) IBM Distributed Power Interconnect Rack Power Distribution Unit:Installation and Maintenance Guide...
  • Page 13: Chapter 2. Installing Pdus With The Vertical-Mounting Plate

    4. If you have a second Rack PDU to install, install it on the vertical-mounting plate with two M3x5 screws that come with the second Rack PDU. Note: You can install Rack and Front-end PDUs on the same vertical-mounting plate. © Copyright IBM Corp. 2003...
  • Page 14 6. If you install a second vertical-mounting plate in the same side of the rack cabinet, repeat steps 2 on page 3 through 5 as required; then, go to step 8 on page 5 IBM Distributed Power Interconnect Rack Power Distribution Unit:Installation and Maintenance Guide...
  • Page 15 7. Install the optional cable-management bracket beside the vertical-mounting plate with four M6 screws and nuts that come with the Rack PDU. 8. If you installed a Universal Rack PDU, connect the power cord that comes with the Rack PDU to the inlet on the Rack PDU. Repeat this step for all Universal Rack PDUs.
  • Page 16 Note: To route a power cable through the cable-management bracket, route the cable through an opening in the bracket and against an upper or lower tab on the bracket, as shown below. Use cable straps as required. IBM Distributed Power Interconnect Rack Power Distribution Unit:Installation and Maintenance Guide...
  • Page 17: Chapter 3. Installing Pdus With The 1U-Mounting Bracket

    2. Verify that the circuit-breaker switch is in the Off position before installing a Rack PDU. 3. Attach a Rack PDU to the 1U-mounting bracket with two M3x5 screws that come with the Rack PDU. © Copyright IBM Corp. 2003...
  • Page 18 U level as the 1U- mounting bracket. Use two M6 screws that come with the Rack PDU. IBM Distributed Power Interconnect Rack Power Distribution Unit:Installation and Maintenance Guide...
  • Page 19 7. Some rack cabinets have 1U mounting space in the side of the rack cabinet where you can install the 1U-mounting bracket as shown below. Note: You will not install the 1U blank filler panel if you install your Rack PDUs this way.
  • Page 20 Rack PDUs. 12. Route all the other power cables neatly and secure the power cables with cable straps. IBM Distributed Power Interconnect Rack Power Distribution Unit:Installation and Maintenance Guide...
  • Page 21: Chapter 4. Hardware Maintenance Information

    Rack PDUs. Field replaceable unit part numbers IBM FRU part numbers are subject to change without notice. This section contains a listing of the FRU part numbers available at the time this document was published. FRU Part #...
  • Page 22: Getting Help And Technical Assistance

    If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This appendix contains information about where to go for additional information about ™...
  • Page 23: Getting Help And Information From The World Wide Web

    Getting help and information from the World Wide Web On the World Wide Web, the IBM Web site has up-to-date information about IBM xSeries and IntelliStation products, services, and support. The address for IBM xSeries information is http://www.ibm.com/eserver/xseries/. The address for IBM IntelliStation information is http://www.ibm.com/pc/intellistation/.
  • Page 24 IBM Distributed Power Interconnect Rack Power Distribution Unit:Installation and Maintenance Guide...
  • Page 25: Chapter 5. Rack Pdu Specifications

    16 A (VDE) / 20 A (UL/CSA) Power outlets 100-127V Rack PDU: Six NEMA 5-15 outlets rated at 10 A (VDE) / 15 A (UL/CSA) Universal Rack PDU: Seven IEC 320-C13 outlets rated at 10 A (VDE) / 15 A (UL/CSA) © Copyright IBM Corp. 2003...
  • Page 26 14-19 A, do not connect more than two Rack PDU power cords to the same branch circuit. • 20 A or greater, you can connect up to three Rack PDU power cords to the same branch circuit. IBM Distributed Power Interconnect Rack Power Distribution Unit:Installation and Maintenance Guide...
  • Page 27: Appendix A. Warranty Information

    1. parts and labor during the first year of the warranty period 2. parts only, on an exchange basis, in the second and third years of the warranty period. IBM will charge you for any labor it provides in performance of the repair or replacement.
  • Page 28: Warranty Service And Support

    Statement of Limited Warranty does not include on-site assistance with this activity. Warranty service and support With the original purchase of an IBM xSeries or IntelliStation system, you have access to extensive service and support. During the IBM Machine warranty period, you may call IBM or your reseller for problem-determination assistance under the terms of the IBM Statement of Limited Warranty.
  • Page 29: International Warranty Service

    If you travel with your xSeries or IntelliStation system or relocate it to a country or region where your system is sold and serviced by IBM or IBM resellers authorized to perform warranty service, International Warranty Service (IWS) is available during the warranty period.
  • Page 30: Ibm Statement Of Limited Warranty Z125-4753-06 8/2000

    Country-unique Terms. The terms of Part 2 replace or modify those of Part 1. The warranties provided by IBM in this Statement of Limited Warranty apply only to Machines you purchase for your use, and not for resale, from IBM or your reseller. The term “Machine” means an IBM machine, its features, conversions, upgrades, elements, or accessories, or any combination of them.
  • Page 31 IBM or your reseller of changes in a Machine's location. IBM is responsible for loss of, or damage to, your Machine while it is 1) in IBM's possession or 2) in transit in those cases where IBM is responsible for the transportation charges.
  • Page 32: Part 2 - Country-Unique Terms

    “Machine” includes Machine Code and Licensed Internal Code. This limit also applies to IBM's suppliers and your reseller. It is the maximum for which IBM, its suppliers, and your reseller are collectively responsible. UNDER NO CIRCUMSTANCES IS IBM LIABLE FOR ANY OF THE FOLLOWING: 1) THIRD-PARTY CLAIMS AGAINST YOU FOR DAMAGES (OTHER THAN THOSE UNDER THE FIRST ITEM LISTED ABOVE);...
  • Page 33 Limitation of Liability: The following is added to this Section: Where IBM is in breach of a condition or warranty implied by the Trade Practices Act 1974 or other similar legislation, IBM's liability is limited to the repair or replacement of the goods or the supply of equivalent goods.
  • Page 34 PEOPLE'S REPUBLIC OF CHINA (PRC) Governing Law: The following replaces this Section: Both you and IBM consent to the application of the laws of the State of New York (except when local law requires otherwise) to govern, interpret, and enforce all your and IBM’s rights, duties, and obligations arising from, or relating in any manner to, the...
  • Page 35 The minimum warranty period for Machines is six months. In case IBM or your reseller is unable to repair an IBM Machine, you can alternatively ask for a partial refund as far as justified by the reduced value of the unrepaired Machine or ask for a cancellation of the respective agreement for such Machine and get your money refunded.
  • Page 36 Limitation of Liability: The following replaces item 2 in this Section: as to any other actual direct damages, IBM's liability will be limited to the total amount you paid for the Machine that is the subject of the claim. For purposes of this item, the term “Machine”...
  • Page 37 The following item is added to this paragraph: 3. breach of IBM's obligations implied by Section 12 of the Sale of Goods Act 1979 or Section 2 of the Supply of Goods and Services Act 1982.
  • Page 38 IBM Distributed Power Interconnect Rack Power Distribution Unit:Installation and Maintenance Guide...
  • Page 39: Appendix B. Notices

    Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk.
  • Page 40: Trademarks

    IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software may differ from its retail version (if available), and may not include user manuals or all program functionality.
  • Page 41: Product Recycling And Disposal

    Power cords For your safety, IBM provides a power cord with a grounded attachment plug to use with this IBM product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet.
  • Page 42 IBM Distributed Power Interconnect Rack Power Distribution Unit:Installation and Maintenance Guide...
  • Page 44 IBM@ Part Number: 02R2738 (1P) P/N:02R2738 *1P02R2738*...

Table of Contents