Advertisement

Quick Links

Installation - Parts
®
E-Flo
System for Urethane
For dispensing and metering single component urethane. For professional use only.
Not approved for use in explosive atmospheres or hazardous (classified) locations.
See page 4 for system component information.
Important Safety Instructions
Read all warnings and instructions in this
manual and in related manuals before
using the equipment. Save all
instructions.
iQ Dispense
3A8217A
EN

Advertisement

Table of Contents
loading

Summary of Contents for Graco E-flo iQ 26B543

  • Page 1 Installation - Parts ® E-Flo iQ Dispense System for Urethane 3A8217A For dispensing and metering single component urethane. For professional use only. Not approved for use in explosive atmospheres or hazardous (classified) locations. See page 4 for system component information. Important Safety Instructions Read all warnings and instructions in this manual and in related manuals before...
  • Page 2: Table Of Contents

    Contents Recycling and Disposal ..... 42 Related Manuals ......3 End of Product Life .
  • Page 3: Related Manuals

    Graco Standard Warranty ....80 Graco Information......80...
  • Page 4: Models

    Models Models For dispense system component information, see Dispense System Component Identification on page 9. Single Systems Main Hose WIP Hose Platen Part No. Length Length Hose Option Option Pump Option Valve Option 26B543 10 ft 26B544 15 ft None 26B545 20 ft Heated Axial...
  • Page 5: Dispense System Pressure

    Models Dispense System Pressure Due to factors such as the dispensing system design, the material being pumped, and the flow rate, the dynamic pressure will not reach the rated working (stall) pressure of the system. Pump Working (Stall) Pressure Max Dynamic (Run) Pressure Lower Size 4,000 29.0...
  • Page 6: Warnings

    Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
  • Page 7 Warnings WARNING MOVING PARTS HAZARD Moving parts can pinch, cut or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure and disconnect all power sources.
  • Page 8 Warnings WARNING SPLATTER HAZARD Hot or toxic fluid can cause serious injury if splashed in the eyes or on skin. During blow off of platen, splatter may occur. • Use minimum air pressure when removing platen from drum. TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
  • Page 9: Dispense System Component Identification

    Dispense System Component Identification Dispense System Component Identification Single Ram NOTE: F . 1 shows a typical E-Flo iQ dispense system installation with a single iQ ram supply unit, hoses, connectors, and an Axial Dispense Valve. Some installations may require only one hose depending on the needs of the system.
  • Page 10: Tandem Ram

    Dispense System Component Identification Tandem Ram Tandem E-Flo iQ Dispense Systems consist of two NOTE: F . 2 shows a typical E-Flo iQ dispense system rams connected using a 3-way block with ball valves, installation with a tandem iQ ram supply unit, hoses, and are controlled by a single ADM.Tandem E-Flo iQ connectors, and an Axial Dispense Valve.
  • Page 11: Supply Unit Component Identification

    Supply Unit Component Identification Supply Unit Component Identification iQ Ram Supply Unit NOTICE Always lift the iQ Ram Supply Unit at the proper lift D200s 6.5 in. Dual Post locations (see F . 3). Do not lift in any other way. Failure to lift at the proper lift locations can result in damage to the Supply System.
  • Page 12: Power Disconnect

    Supply Unit Component Identification Power Disconnect Every E-Flo iQ Dispense System has a red and yellow Disconnect Switch which shuts off power to the entire system. The Disconnect Switch (AZ) is located on the Heat Control Box (AX), see F .
  • Page 13: Integrated Air Controls (Ag)

    Supply Unit Component Identification Integrated Air Controls (AG) Air Line Accessories The integrated air controls include: See F . 3. • Main Air Slider Valve (BA): turns the air on and off • Air Line Drain Valve (AS) (not supplied): removes to the iQ Ram Supply Unit.
  • Page 14: Advanced Display Module (Adm)

    Supply Unit Component Identification Advanced Display Module (ADM) Front and Rear Views . 6: ADM Component Identification Key: CA Startup/Shutdown CG Lock/Setup Starts up or shuts down the system. Toggles Toggles between Run screens and the iQ Menu. between Active and Inactive system. CH Directional Keypad CB System Status Indicator LED Navigate within a screen or to a new screen.
  • Page 15: Platen (Ad) Component Identification

    Supply Unit Component Identification Platen (AD) Component Identification Key: EA Plate EB Wiper EC Heater Cover EF Bleed Stick EG Bleed Port EH Air Assist Body Check Valve EJ Wiper Plate (under wiper) EK O-ring Seal (not shown) EL Platen Valve Port EM Platen Valve Cap 3A8217A...
  • Page 16: Electric Driver Communication Connections

    Supply Unit Component Identification Electric Driver Communication Connections Single Ram Port 1 Port 2 Port 4 Port 3 Connection Port 4 Connection Port 6 Port 3 Port 5 Pump Solenoid Dispense Valve Valve Power (M8 4 pin) Solenoid Junction Box (M8 4 pin) Port C3 Power...
  • Page 17 Supply Unit Component Identification Tandem Ram Port 1 Port 2 Port 4 Connection Port 3 Connection Port 4 Port 6 Port 3 Port 5 Pump Solenoid Tandem Tandem Valve Block Block Power (M8 4 pin) dispense discrete Junction Box valve Robot Port C3 Solenoid...
  • Page 18: Installing Tandem

    Supply Unit Component Identification Installing Tandem 1. Remove cable from port C1 on ram 1 and plug into female end of splitter. Splitter is included in tandem kit. 2. Install 0.4 m cable (121226) included in tandem kit from male end of splitter to part C1 on ram 1. 3.
  • Page 19 Supply Unit Component Identification Low Level Sensor Kit, 25E447 NOTE: The Low Level Sensor Kit is an optional accessory for Single Ram Systems, and a required accessory for Tandem Ram Systems. To install the Low Level Sensor: 1. Turn the Disconnect Switch (AZ) OFF. 2.
  • Page 20: Power Junction Box And Heat Control Box Connections

    Supply Unit Component Identification Power Junction Box and Heat Control Box Connections Single Ram . 11 Key: C1 GCA CAN Port (to ADM) C2 GCA CAN Port (to CGM) C3 Low and Empty Level Sensor Input C4 Discrete Integration Cable C5 Heated Hose/Accessory Connection C6 Heated Pump Connection C7 Heated Platen Connection...
  • Page 21 Supply Unit Component Identification Tandem Ram . 12 iQ Ram Supply Unit 1 iQ Ram Supply Unit 2 Key: Key: C1 GCA CAN Port (to ADM splitter cable on Tandem Block C1 GCA CAN Port (to ADM splitter cable on Tandem Block (R) using the supplied CAN cable (124003)) (R) using the supplied CAN cable (124003)) C2 GCA CAN Port (to CGM)
  • Page 22: Installation

    Installation Installation Grounding The equipment must be grounded to reduce the risk All electrical wiring must be done by a qualified elec- of static sparking and electric shock. Electric or static trician and comply with all local codes and regula- sparking can cause fumes to ignite or explode.
  • Page 23: Power Requirements

    Installation Power Requirements 2. Loosen the screws and remove the cover (318) on the Power Junction Box (AJ). Each iQ Ram Supply Unit requires a dedicated circuit 3. Loosen the screws and remove the cover (350) on protected with a circuit breaker. the Heat Control Box (AX).
  • Page 24: Attach Drum Stops

    Installation Attach Drum Stops Install Vented Oil Cap Before Using Equipment. The iQ Ram Supply Units are shipped with drum stops in place to help position the drum on the Ram Assembly The Driver gear-box is shipped from the factory (AA).
  • Page 25: Setup

    Setup Setup 2. If using a Single iQ Ram Supply System, connect the Ram Supply System to Supply Hose 1 Fitting (E) to the fluid check valve (AE) on the iQ Ram Supply Unit (A). Remove the Axial Dispense Valve (B) from its 3.
  • Page 26 Setup c. Connect Tandem Hose 1 (L) and Tandem Hose 7. If two hoses are used, connect Supply Hose 2 (D) to the inlet fitting on the Dispense Valve (B). If only one 2 (M) from the supply system to the Tandem hose is used, connect Supply Hose 1 (C) to the inlet Block (R).
  • Page 27: Electrical Connections

    Setup Electrical Connections Pressure Transducer 1. If using a Single iQ Ram Supply System, connect the pressure transducer cable (PC) from dispense valve (B) to Port 6 on the Electric Driver (AB). See Electric Driver Communication Connections for Single Rams on page 16. 2.
  • Page 28 Setup Dispense Valve Solenoid 3. If using a Single iQ Ram Supply System: a. Connect the solenoid valve cable (VC) to the M8 4 pin end of the splitter cable attached to Port 4 on the Electric Driver (AB). See Electric Driver Communication Connections for Single Rams on page 16.
  • Page 29: Heat Connections (Hoses And Accessories)

    Setup Heat Connections (Hoses and Example 1: Single system with two heated hoses and one heated dispense valve. Accessories) • Hose 1 - Circular electrical connection to Port 1 (C5). 1. Connect heated hoses (with circular electrical connectors) to Heat Control Box Ports 1, Port 2 or •...
  • Page 30 Setup Example 2: Tandem system with three heated hoses, • Hose 3 - From tandem block - circular electrical one heated tandem block and one heated dispense connector to port 2 (C5) of ram 1 or ram 2. * valve. •...
  • Page 31: Wet Cup

    Setup Wet Cup Before starting, fill the Wet Cup (AN) 1/3 full with Graco Throat Seal Liquid (TSL) or a compatible solvent. Torque the Wet Cup The Wet Cup (AN) is torqued at the factory; however, throat packing seals on Severe Duty pumps may relax over time.
  • Page 32: Hose Care Guidelines

    Hose Care Guidelines Hose Care Guidelines Do not flex hose when cold. Fluids subjected to heat in confined spaces can create a rapid rise in pressure due to the thermal expansion. Over-pressurization can result in equip- ment rupture and serious injury. •...
  • Page 33: Flush Before Using Equipment

    Hose Care Guidelines Flush Before Using Equipment The equipment was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid contaminating the fluid with oil, flush the equipment with a compatible solvent before using the equipment. See the E-Flo iQ Supply System Operation manual for information about flushing the equipment.
  • Page 34: Check Resistance (Heated Systems)

    Check Resistance (Heated Systems) Check Resistance (Heated Systems) Check Sensor Resistance Check Heater Resistance To reduce risk of injury or damage to equipment, To reduce risk of injury or damage to equipment, conduct these electrical checks with the Power conduct these electrical checks with the Power Junction Box Switch (AK) and the Disconnect Switch Junction Box Switch (AK) and the Disconnect Switch (AZ) OFF.
  • Page 35 Check Resistance (Heated Systems) Table 1: Sensors RTD Range RTD Pin Heater Element Heater Pin Port Zone Component (Ohms) Numbers Resistance (Ohms) Numbers Heated Hose G, K See hose manual See hose manual See accessory Heated Accessory 1 M, K See accessory manual manual Heated Hose...
  • Page 36: Pressure Relief Procedure

    Pressure Relief Procedure Pressure Relief Procedure soft key to open the Axial Dispense Valve (B) Follow the Pressure Relief Procedure whenever allowing the system to depressurize. you see this symbol. Single Unit Run Screen Pump Pressure This equipment stays pressurized until pressure is manually relieved.
  • Page 37 Pressure Relief Procedure 7. Open the Pump Bleed Valve (AM). Have a container ready to catch the drainage. 8. Leave the Pump Bleed Valve (AM) open until ready to dispense again. 9. If you suspect the dispense valve is clogged or that pressure has not been fully relieved: a.
  • Page 38: Shutdown And Care Of The Pump

    Shutdown and Care of the Pump Shutdown and Care of the Pump Change Drums NOTICE Keep hands away from the pump inlet to prevent To prevent damage to the pump from rust, never serious injury from moving parts. leave water or water-based fluid in a carbon steel pump overnight.
  • Page 39 Shutdown and Care of the Pump 2. Set the Ram Air Regulator (BB) to 0 psi. 3. Set the Ram Director Valve (BC) to UP. 4. Slowly increase the pressure on the Ram Air Regulator until the Platen (AD) starts to raise, and immediately press and hold the Blowoff Button (BE) until the Platen is completely out of the drum.
  • Page 40: Maintenance

    The oil level should be near the half- way point of the sight glass when the Driver (AB) is not running. If the oil is low, open the fill cap and add Graco Part No. 16W645 ISO 220 silicone-free synthetic EP NOTICE gear oil.
  • Page 41: Platen Maintenance

    Maintenance Platen Maintenance Remove and Reinstall Wipers Remove Platen Wipers 1. Follow the Pressure Relief Procedure on page 36. 2. Turn the Power Junction Box Switch (AK) and the 1. Follow the steps to Change Drums on page 38. Disconnect Switch (AZ) OFF. 2.
  • Page 42: Recycling And Disposal

    Maintenance Recycling and Disposal Reinstall Platen Wipers 1. Using a wooden or plastic tool to prevent damage to the Wiper (EB), clean all material from the seal End of Product Life grooves. 2. Working from the bottom, angle one Wiper (EB) At the end of the product’s useful life, dismantle and over the back of the Platen (AD).
  • Page 43: Troubleshooting

    Troubleshooting Troubleshooting 2. Check all possible problems and causes before disassembling the Ram, Pump, or Platen. NOTE: Refer to Supply Unit Operation manual for descriptions of ADM diagnostic codes. NOTE: Refer to your Pump package manual for Pump troubleshooting. 1. Follow Pressure Relief Procedure, page 36, before checking or repairing the Ram, Pump, or Platen.
  • Page 44: Heat Control Box Troubleshooting

    Troubleshooting Heat Control Box Troubleshooting Problem Cause Solution System does not heat. Blown fuse. Replace fuse. Over-temperature switch tripped. Measure over-temperature switch resistance. It should read close to 0 ohms when at room temperature. If open, replace over-temperature switch. Cable to over-temperature switch is Check connection of cable to off or broken.
  • Page 45: Repair

    Repair Repair Connect Platen 55 Gallon Platen Disconnect Pump from Platen 1. Place o-ring (428) from mounting kit on the Platen (AD). If attached to plate, place Displacement Pump The Pump is mounted to the Platens by different mount- (AC) onto Platen (AD). See F .
  • Page 46: Remove Displacement Pump

    Repair Remove Displacement Pump 5. Raise the Driver (AB): a. Loosen nut (105a) under Ram bar and thread it down the threaded rod (106) to the lift ring adapter (107) holding the Driver (AB). Use wrench on nut (105) on top of Ram bar to raise Driver (AB).
  • Page 47: Install Displacement Pump

    Repair Remove Driver 7. Use two people to lift out the Displacement Pump (AC). To avoid serious injury when installing and removing the Driver, make sure the Driver is supported at all times. 1. Follow the Pressure Relief Procedure on page 36. 2.
  • Page 48: Install Driver

    Repair Install Driver To avoid serious injury when installing and removing the Driver, make sure the Driver is supported at all times. D200s 6.5 in. Ram Supply Units 55 gallon platen: 1. Using a capable hoist, insert tie rods into the Dis- placement Pump (AC) and secure the Driver (AB) to .
  • Page 49: Ram Supply Unit Repair

    Repair 2. Connect power to the Driver (AB). Follow a-e of step 4 on page 47 in reverse. 3. Turn the Power Junction Box Switch (AK) and the Disconnect Switch (AZ) ON. Ram Supply Unit Repair To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 36.
  • Page 50 Repair 6. Remove retaining ring (136) by gripping the ring tab 4. Install retaining ring (134) and tie bar (219). Perform with a pair of pliers and rotating the ring out of its steps to Disassemble Ram Piston in reverse groove.
  • Page 51: Replace Heat Control Box Electrical Component(S)

    Repair Replace Heat Control Box Electrical Component(s) 2. Remove the door (350) on the Heat Control Box (AX). 3. Use a non-conductive fuse puller tool to remove the blown fuse. DANGER SEVERE ELECTRIC SHOCK HAZARD This equipment can be powered by more than 240 V. NOTICE Contact with this voltage will cause death or serious Using an improper tool, such as a screwdriver or pli-...
  • Page 52 Repair Replace Advanced Display Module (ADM) c. Remove the four screws (333) used to mount the AMZ to the back of the Heat Control Box NOTICE (AX) and remove the AMZ. The ADM stores useful lifetime and diagnostic data 4. Insert the new AMZ: that will be lost when it is replaced.
  • Page 53: Replace Fuses In Harness (25R652)

    Repair Replace Fuses in Harness (25R652) The harness comes with fuses installed. Follow these steps to replace a fuse. 1. Turn the Disconnect Switch (AZ) OFF. 2. Remove the Heat Control Box door (350). 3. Unscrew the spring-loaded fuse holder to open it. The fuse can be easily removed by hand.
  • Page 54: Parts

    Parts Parts D200s 6.5 in. Ram Supply Units NOTE: If using a tandem system, the ADM is only included with the iQ Ram Supply Unit 1 (A). Detail A 102, 103, 107,108 Detail B 107,108 107,108 3A8217A...
  • Page 55 Parts D200s 6.5 in. Ram Supply Units Ref. Part Description Qty. Ref. Part Description Qty. 130787 SENSOR, barrel 102040 123673 HARNESS 110755 WASHER, plain 255381 ACTUATOR, sensor, 117017 WASHER low/empty, painted 15V954 LABEL, valve, shutoff, air con- BRACKET, lvl sensor, dual, trol D200 LABEL, cross bar...
  • Page 56: D200S Pump Mounts For 55 Gallon (200 Liter) Platen

    Parts D200s Pump Mounts for 55 Gallon (200 Liter) Platen Note: See page 54 for kit configuration table. 303, 305 302, 304 TI10771A Ref. Part Description 15M531 ROD, platen 101015 WASHER, lock C19187 101533 WASHER, spring lock 101535 ROD, threaded 15J991 ADAPTER, lift, ring 15J993...
  • Page 57 Parts Heated Power Junction Box See Detail A See Detail B See Detail C Detail C Detail B Detail A Ref. Part Description Qty. Ref. Part Description Qty. 321† 123970 SWITCH, disconnect, 40A 205* 108050 WASHER, lock, spring 196548 LABEL, caution 217* 121518 SCREW...
  • Page 58: Heat Control Box

    Parts Heat Control Box 336, Ref. Part Description Qty. Ref. Part Description Qty. HARNESS, ground, heat ENCLOSURE, electrical, heat, 121000 CABLE, can, female/female 0.5m painted HARNESS, power, incoming 25R533 MODULE, gca 441† 111307 WASHER, lock, external 116595 SCREW 348† 16T440 121171 GRIP, cord LABEL, multiple, control, heat...
  • Page 59: 55 Gallon Platen

    Parts 55 Gallon Platen 200 Liter (55 Gallon) Platen, 255319 and 255320 200 Liter (55 Gallon) Platen Parts *428 *426 Ref. Part Description Qty. 257697 HANDLE, bleed assy 255652 SEAL, wiper, drum, 55 gal., neo- prene; for 255664 only. *427 255653 SEAL, wiper, drum, 55 gal., EPDM;...
  • Page 60: Tandem Block, Urethane, 26B488

    Parts Tandem Block, Urethane, 26B488 487,488 Ref. Part Description Qty. Ref. Part Description Qty. 491* 25R439 KIT, low level sensor BLOCK, 3 way, S, 1” NPT 492* 121226 VALVE, shuttle 5/32 C38302 FITTING, nipple 493* 129301 CABLE, ext, TOF hose 15 ft 473* SEALANT, pipe, SST...
  • Page 61: Kits And Accessories

    Kits and Accessories Kits and Accessories Accessories are available from Graco. Make certain all accessories are adequately sized and pressure-rated to meet the system’s requirements. System Kits and Accessories Light Tower Kit, 255467 For D200s single supply systems. See the E-Flo iQ Supply System Operation manual for more information.
  • Page 62: Drum Kits And Accessories

    Kits and Accessories Tandem Block Stand, 26B482 To install the Tandem Block Stand: For use with tandem systems only. 1. Use the holes in the Tandem Block Stand support (551) as a guide and drill holes for 1/2 in. (13 mm) anchors.
  • Page 63: I/O Cable, 122029

    Kits and Accessories I/O Cable, 122029 Heat Extension Cables See the E-Flo iQ Supply System Operation manual for Part Description Length setup and pin out information. 129300 4.6 m CABLE, ext, TOF hose Part Description Length 129301 7.6 m CABLE, ext, TOF hose 15.0 m 128441 CABLE, GCA, M12-8p...
  • Page 64: Check-Mate 200 Cs Pump Heater Kit, 25R450

    Kits and Accessories Check-Mate 200 CS Pump Heater Kit, 25R450 See Detail A Detail A . 49: Check-Mate 200 CS Pump Heater Kit, 25R450 Ref. Part Description Qty. 116343 SCREW 121980 HEATER, pump, 725 watt 111307 WASHER 18B862 HOLDER, rtd, overtemp 100166 16K094 SWITCH, overtemp, horizontal...
  • Page 65: Platen Heater Kit, 25R451

    Kits and Accessories Platen Heater Kit, 25R451 Detail B 530, 531 Detail D Detail A 533, 534 Detail C . 50: Platen Heater Kit, 25R451 Ref. Part Description Qty. HARNESS, ground, 14awg, 18” long HARNESS, heat, wiper, 55 25R666 WASHER gallon CONDUCTOR, block, heater 116343...
  • Page 66: Communication Gateway Module (Cgm) Kits

    Kits and Accessories Communication Gateway Module (CGM) Kits CAN Port 2 CAN Port 1 . 51: CGM CAN Connections . 52: Disassembling the CGM 5. Using the four M4-0.7 x 20 mm mounting screws CGM Kits included in the kit, mount the base (DD) to the CGM Part Number Description Heat Option bracket.
  • Page 67 CGM as ceNet, or PROFIBUS cable to the fieldbus device. applicable. 12. Refer to the Graco Control Architecture Module pro- gramming manual for step-by-step instructions on how to update the software version of GCA mod- ules.
  • Page 68: Platen Valve Kit, Urethane, 26B637

    Kits and Accessories Platen Valve Kit, Urethane, 26B637 . 55: Platen Valve Kit, Urethane, 26B637 Ref. Part Description Qty. 710 17K616 FITTING, nipple VALVE, 25, npt/b, 000, 711 123140 FITTING, cap 701 V25AB000BA adj/sol, amb 712 --- SEALANT, pipe, sst 702 100721 PLUG, pipe 713 ---...
  • Page 69 Kits and Accessories 11. The harness (714) has an M8 connector and an To install the Platen Valve Kit on a 55 gallon system: M12 connector. Connect the M12 connector that was originally connected to port 3 on the Electric Driver (AB) to the M12 connector on the harness (714).
  • Page 70 Kits and Accessories 14. Connect the nylon tube (715) to the elbow fitting (716) and the platen valve (701). . 57 3A8217A...
  • Page 71: Dimensions

    Dimensions Dimensions Dimensions See the identification plate (ID) for the weight of your Ram Size in. (mm) Ram Supply Unit. Total Height (A) 96 (2438) Ram Height (B) 69 (1753) Extended Ram Height (C) 125 (3175) Base Depth (D) 25 (635) Machine Width (E) 45 (1143) Mounting Hole Depth (F)
  • Page 72: Pump Performance

    Pump Performance Pump Performance Calculate Fluid Outlet Pressure To calculate fluid outlet pressure (psi/MPa/bar) at a specific fluid flow (gpm/lpm) and electrical power, use the following instructions and pump data chart. 1. Refer to the desired flow along the bottom of the chart.
  • Page 73: Wiring Diagrams

    Wiring Diagrams Wiring Diagrams 3A8217A...
  • Page 74 Wiring Diagrams 3A8217A...
  • Page 75 Wiring Diagrams 3A8217A...
  • Page 76 Wiring Diagrams 3A8217A...
  • Page 77 Wiring Diagrams 3A8217A...
  • Page 78 Wiring Diagrams 3A8217A...
  • Page 79: Technical Specifications

    Technical Specifications Technical Specifications E-Flo iQ Dispense System for Urethane Metric Maximum fluid operating temperature 158°F 70°C Maximum working pressure 4000 psi 28 MPa, 276 bar Maximum driver cycle rate 25 cycles per minute Air inlet size (supply system) 3/4 npt(f) Ambient operating temperature range (supply 32-120°F 0-49°C...
  • Page 80: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

Table of Contents