Connections And Displays; Possible States Of The Leds - Siemens SIMATIC RTLS Device Manual

Localization systems
Hide thumbs Also See for SIMATIC RTLS:
Table of Contents

Advertisement

2.2 Connections and displays

Connection
P1 - Power, Digital
P3 - Antenna
Fuse
Display
D1 - Radio LED (yellow)
D2 - Run LED (green)
D3 - Bus LED (yellow)

2.2.1 Possible states of the LEDs

D1 - Radio LED D2 - Run LED
Flashes once
for 0.5 second
any
any
6
Description
Power supply and digital input signals
RP-SMA - Antenna screw connector
Mini blade fuse, 2 A
Description
LED signaling the activity of the Locating Manager (sending
and receiving radio signals)
LED signaling the device's operating status
LED signaling activity of the bus system (CAN-bus or IBIS)
D3 - Bus LED
Off
flashes once for
flashes once for
0.5 second
0.5 second
flashes every 3
any
seconds
flashes
any
permanently
Description
Device is inactive
Device start up test
Carry out a start-up test in order to
test proper functionality of the LEDs
and the device. To this end, observe
all three LEDs whilst switching on the
device's power supply. All three
LEDs flashing simultaneously once
for half a second indicates the just
operating status of both device and
LEDs.
Device operating in "SLOW" state
Device operating in "FAST" state