Gas fired boiler with control system
Table of Contents

Advertisement

N
!
OTICE
The safety labels shown below are
affixed to your boiler. Although the
labels are of high quality, they may
become dislodged or unreadable
over time. Contact Patterson-Kelley
at 570.476.7261 or toll-free at
877.728.5351 for replacements.
Gas may lose its odor. Proper gas
sensing equipment and procedures
should be used for leak checks.
Failure to detect gas leaks could
result in injury or death.
Bump Hazard from Overhead Ductwork and Piping
Injury Hazard! Install components with adequate vertical clearance.
Pressure Hazards
Pressure Hazard! Hot fluids. Install isolation valves on boiler water inlet and outlet.
Make sure isolation valves are closed before servicing boiler.
Pressure Hazard! Hot fluids. Annually test safety relief valve(s) for proper operation.
Do not operate boiler with faulty relief valve(s).
Training
Proper training is the best protection against accidents. It is
essential to read, understand, and follow the recommendations
of this manual before installing, operating, or servicing this
equipment. Failure to do so could result in fire or explosion and
serious injury, death, and/or property damage.
Operating and service personnel must be thoroughly familiar with
the basic construction of the P-K SOLIS 1500, 2000, 2500, &
3000 boilers, the use and locations of the controls, the operation
of the boilers, adjustment of their various mechanisms, and all
applicable safety precautions. If any of the provisions of this
manual are not fully and completely understood, contact
Patterson-Kelley Technical Service at 570.476.7261 or toll free at
877.728.5351.
Hazard Warnings
Electrical Hazards
Shock Hazard! Properly Lockout/Tagout the
electrical service and all other energy sources
before working on or near the boiler.
Shock Hazard! Do not spray water directly on
this boiler or any electrical components.
Electrical Hazard! Do not alter wiring
connections.
Crush Hazards
Lifting Hazards! Use properly rated lifting
equipment to lift and position the boiler. The
load is unbalanced. Test the balance before
lifting off the floor. Do not allow personnel
beneath the lifted load. Refer to the
approximate weights in the table below
Boiler Model
P-K SOLIS™
Gas Fired Boiler
Technical Service 1.877.728.5351
Weight in
Pounds
SL-1500
2,445 lbs.
SL-2000
2,445 lbs.
SL-2500
2,650 lbs.
SL-3000
2,650 lbs.
.