Baxi 45 HTE Installation, Operation And Maintenance Manual page 45

Floor standing condensing gas boilers
Table of Contents

Advertisement

Available languages

Available languages

3.9 table of faults and error messages
Error
Description of fault
code
E10
Outdoor temperature sensor fault
E20
ntc output sensor failure
E50
domestic hot water ntc sensor failure
E110
safety or flue gas thermostat tripped
E128
Loss of flame during operation (the
ionization current has fallen below
the limit)
E129
Minimum fan speed limit is hurt
E132
floor thermostat tripped
E133
no gas
E151
boiler circuit board error
E153
the reset key has been pressed
inappropriately
E154
internal error on boiler circuit module
E160
fan speed threshold not reached
E164
no hydraulic differential pressure
switch enabling signal
All the faults are displayed in order of importance; if several faults occur simultaneously, the first to be displayed
is the one with highest priority. After the cause of the first fault has been removed, the second one will be
displayed, and so on.
If any given fault occurs frequently, contact the authorised Service Centre.
IstructIons pErtaInIng to thE usEr
Corrective action
Call an authorised service centre.
Call an authorised service centre.
Call an authorised service centre.
Press the reset key (for about 2 seconds: if this device is triggered repeatedly, call
the authorised service centre)
Call an authorised service centre.
Call an authorised service centre.
Call an authorised service centre.
Press the reset key (for about 2 seconds); if the fault persists, call the authorised
service centre)
If
symbol is displayed, press the reset
electricity supply to the boiler for at least 10 seconds; if the fault persists, call the
authorised service centre.
Check the positioning of the ignition and flame sensing electrode (see section 16).
Press the key again (about 2 seconds)
Press and hold reset button (2 seconds approx­.) then press again when warning
E153 appears
Call an authorised service centre.
Check that the system is at the rated pressure. (refer to the section on filling the
system). if the fault persists, call the authorised service centre.
45
button otherwise switch off the
912.403.1 - IE

Advertisement

Table of Contents
loading

This manual is also suitable for:

65 hte

Table of Contents