Baxi 45 HTE Installation, Operation And Maintenance Manual page 43

Floor standing condensing gas boilers
Table of Contents

Advertisement

Available languages

Available languages

Parameter
Parameter description
N.
P1
Time of day setting
P5
Minimum central heating temperature setting (°C)
P11
Start of first daily period of automatic central heating
P12
End of first daily period of automatic central heating
P13
Start of second daily period of automatic central heating
P14
End of second daily period of automatic central heating
P15
Start of third daily period of automatic heating
P16
End of third daily period of automatic central heating
*
P31
Start of first daily period of domestic hot water production
*
P32
End of first daily period of domestic hot water production
*
P33
Start of second daily period of domestic hot water production
*
P34
End of second daily period of domestic hot water production
*
P35
Start of third daily period of domestic hot water production
*
P36
Fine End of third daily period of domestic hot water production
P45
Reset of daily central heating and domestic hot water production programs (factory settings).
Press the - + keys together for about 3 seconds; the number 1 appears on the display.
Confirm by pressing either of the
*
Parameters for program lines P31 to P36 are displayed only if Domestic Hot Water (D.H.W.) program (pa-
rameter H91 see section 14) is activated.
IstructIons pErtaInIng to thE usEr
3.7 table fo user-settable parameters
keys
43
Factory
Range
setting
———-
0...23:59
25
25..80
6:00
00:00...24:00
22:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
24:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0
0...1
912.403.1 - IE